Evaporator Airflow
System Net Heating Capacity*
| 460/230V, 3 Phase, 60 Hz Power | 380/190V, 3 Phase, 50 Hz Power | |||||
|---|---|---|---|---|---|---|
| Heating Capacity | Heating Capacity | |||||
| Watts | Kcal/hr | BTU/hr | Watts | Kcal/hr | BTU/hr | |
| MAGNUM PLUS normal | 5,250 | 4,515 | 17,914 | 3,900 | 3,353 | 13,300 |
| MAGNUM PLUS extended | 7,250 | 6,234 | 24,738 | 5,550 | 4,772 | 18,937 |
| *System net heating capacity includes electric resistance rods and fan heat. | ||||||
MAGNUM PLUS
| External Static Pressure (Pa) | 460/230V, 3 Phase, 60 Hz Power | 380/190V, 3 Phase, 50 Hz Power | ||||||
|---|---|---|---|---|---|---|---|---|
| High Speed | Low Speed | High Speed | Low Speed | |||||
| m3/hr | ft3/min | m3/hr | ft3/min | m3/hr | ft3/min | m3/hr | ft3/min | |
| 0 | 5613 | 3304 | 2895 | 1704 | 4752 | 2797 | 2415 | 1421 |
| 100 | 4930 | 2902 | 1335 | 786 | 3933 | 2315 | 473 | 278 |
| 200 | 4064 | 2392 | — | — | 2833 | 1667 | — | — |
| 300 | 3132 | 1844 | — | — | 1674 | 985 | — | — |
| 400 | 2055 | 1210 | — | — | 448 | 264 | — | — |
| 500 | 963 | 567 | — | — | — | — | — | — |