LogView and Viewing SG+ Logs
With the release of LogView software version 5.9.2.0 (or later), you can now view SG+ Event logs. The following will outline how to interpret the SG+ log. To understand now to use LogView refer to the Help file found within LogView.
The SG+ log can store up to 128 Event logs. The oldest events will be over written in the log automatically.
The latest LogView files can be found on our Web site under Global Marine Solutions Info Central.
Note Logman II PC Rev.
2.7.0 (or later) is required to flashload software or to download
the data logger.
Event Description | ||
Alarm | Alarm Code | An alarm is activated, see “Alarm List” on page 63 for alarm descriptions |
Message | Message code | A message is activated, see “Message List” for message descriptions |
Engine | Shutdown alarm | If an alarm is active and entering shutdown state |
Engine running | The engine is running | |
Restart engine | Restart sequence started | |
Pre Trip | PTI started | PTI start event |
PTI failed | PTI failed | |
PTI OK | PTI completed | |
Configuration | Factory reset | Factory reset initiated by user |
Clock set | Time and date adjusted | |
Power | Power off | Time and date for controller power off |
Power on | Time and date for controller power on | |
Log retrieved | Log retrieved | The event log is retrieved from the unit |
Speed | High to low speed - was XXX RPM | RPM above shift point |
Low to high speed - was XXX RPM | RPM below shift point | |
Low to high speed RPM below limit | RPM below 1500 RPM | |
High to low speed MAGNUM unit detected | A TK MAGNUM unit is detected | |
Low to high speed compressor start detected | Reefer unit controller is resetting | |
Low to high speed water temperature to high Water temperature XXX | If water temperature is above 5 C below alarm high limit | |
Failed to detect speed solenoid | This event is set in the state “LOAD MEAS” if it fails to detect the speed change | |
Fuel | Positive change from X.X to X.X Ga Change in level; +X.X Ga | Positive fuel change detected |
Negative change from X.X to X.X Ga Change in level; - X.X Ga | Negative fuel change detected | |
System | Flashload completed OLD: XXX to NEW: XXX | A new version of the application is loaded |