LogView and Viewing SG+ Logs

With the release of LogView software version 5.9.2.0 (or later), you can now view SG+ Event logs. The following will outline how to interpret the SG+ log. To understand now to use LogView refer to the Help file found within LogView.

The SG+ log can store up to 128 Event logs. The oldest events will be over written in the log automatically.

The latest LogView files can be found on our Web site under Global Marine Solutions Info Central.

Note Logman II PC Rev. 2.7.0 (or later) is required to flashload software or to download the data logger.

Event Description
Alarm Alarm Code An alarm is activated, see “Alarm List” on page 63 for alarm descriptions
Message Message code A message is activated, see “Message List” for message descriptions
Engine Shutdown alarm If an alarm is active and entering shutdown state
Engine running The engine is running
Restart engine Restart sequence started
Pre Trip PTI started PTI start event
PTI failed PTI failed
PTI OK PTI completed
Configuration Factory reset Factory reset initiated by user
Clock set Time and date adjusted
Power Power off Time and date for controller power off
Power on Time and date for controller power on
Log retrieved Log retrieved The event log is retrieved from the unit
Speed High to low speed - was XXX RPM RPM above shift point
Low to high speed - was XXX RPM RPM below shift point
Low to high speed RPM below limit RPM below 1500 RPM
High to low speed MAGNUM unit detected A TK MAGNUM unit is detected
Low to high speed compressor start detected Reefer unit controller is resetting
Low to high speed water temperature to high Water temperature XXX If water temperature is above 5 C below alarm high limit
Failed to detect speed solenoid This event is set in the state “LOAD MEAS” if it fails to detect the speed change
Fuel Positive change from X.X to X.X Ga Change in level; +X.X Ga Positive fuel change detected
Negative change from X.X to X.X Ga Change in level; - X.X Ga Negative fuel change detected
System Flashload completed OLD: XXX to NEW: XXX A new version of the application is loaded