Configuration Menu

The Configuration menu displays a list of functions that identifies unit operating features and current settings. A complete listing of the controller Configuration menu is located on an 11” x 17” foldout in the Diagrams chapter (Diagram Index).

With the unit turned On, allow it to start and stabilize and the display showing the unit status display:

  1. Press the Enter key to view the Menu screen. Press the Down key to scroll down to the CONFIG menu.

  2. Press the Enter key to expand this menu.

  3. Press the UP or DOWN key to scroll to the desired function.

  4. To set a new Configuration screen value:

    1. Press the Enter key with cursor in the desired menu line.

    2. Press the UP or DOWN key to scroll the value to the desired setting.

    3. Press the Enter key and release when the entry is complete. Press the Esc key. The new value appears in the menu line.

  5. Repeat steps 3 and 4 to reset additional configuration values.

  6. Press the Esc key to exit the Configurations screen.

Note Pressing Enter again will display the Overview screen.

Configuration Menu

Unit

  1. Select Unit option and press enter key.

  2. Press UP or DOWN using navigation keys to view the different submenus. Press Enter to access and Esc navigation key to return to the Unit menu screen.

  • In-Range Temperature limit: Sets the temperature value for the controller’s in-range LED and datalogger functions (factory default = 1.5 C [2.7 F]). Enter a value from 0.5 to 5.0 C (0.9 to 8.9 F).

  • Pull Down Selection: Select ON/OFF.

  • Padlock Option : Select ON/OFF.

  • USDA Option: When USDA sensor is mounted you can change the setting here.

  • Log Interval: Sets the data log interval (1 minute or 1/2, 1, 2, or 4 hours).

  • Smart PTI: Select ON/OFF.

  • Unit C/F: Allows to select Fahrenheit or Centigrade.

In Range Pull Down Selection
Economy Min Economy Max
Padlock Option USDA Option
Log Interval Log Smart Option
Aux A to D Option CO2 calibration Offset
O2 calibration Offset Cold Start
Retriever Smart PTI
Smart PTI Max Age Smart PTI Auto Save
Smart PTI Trail Unit C/F

Options

  1. Select Options menu and press enter key.

  2. Press UP or DOWN using navigation keys to view the different submenus. Press Enter to access and Esc navigation key to return to the Options menu screen.

This menu is used to turn ON/OFF a Module/Feature, select a particular option within a module, and tell the controller when a sensor is mounted.

  • Auto Configuration: Select ON/OFF.

  • Heater Type: Select from Extended Capacity and Normal Capacity.

  • Controlled Atmosphere (CA): This turns on the AVL option. Select from None, AVL, TK Fresh, and TK Fresh+. Selecting TK Fresh+ also turns OptiSet ON.

  • Humidity Sensor: This setting can be changed when a humidity sensor is mounted.

  • Suction Pressure Sensor: This setting can be changed when a suction pressure sensor is mounted.

  • Discharge Pressure Sensor: This setting can be changed when a discharge pressure sensor is mounted.

  • Condenser Temperature Sensor: This setting can be changed when a condenser temperature sensor is mounted.

  • Multiple Setpoint (MTS): Selectable or Not Selectable.

  • Cold Treatment (CT): Selectable or Not Selectable

  • Fresh Air Option: This setting can be changed when a condenser temperature sensor is mounted.

  • Energy Logging: On the MP-5000 Controller: captures live Power Draw, in kW; Total Energy Consumed, in kWh; Trip Duration, (Days, hours, mins); Average kW per Hour; Trip Start Date. In the Download File: actual power draw and cumulative trip power draw; total kWh draw since reefer in service (or since software retrofitted, if applicable).

  • Condenser Fan Type: Shows the condenser fan type selection.

  • Evaporator Fan Type: Shows the information on evaporator fan.

  • High Temperature Suction Pressure Sensor: This setting can be changed when a condenser temperature sensor is mounted.

  • Low Temperature Suction Pressure Sensor: This setting can be changed when a condenser temperature sensor is mounted.

Auto Configuration Heater Type
CA Settings Humidity Sensor
Suction Pressure Sensor Discharge Pressure Sensor
Condenser Temp. Sensor Fresh Air Option
Multiple Setpoint(MTS) Cold Treatment (CT)
Multiple Setpoint(MTS)O2 ON Cold Treatment (CT)Energy Logging
Condenser Fan Type Evaporator Fan Type
High Temp. Suction Pressure Sensor Low Temp. Suction Pressure Sensor

System

Note Units without a container number beginning with MAE, MSF, or MWC must be set for USDA temperature sensing.
  1. Select System menu and press enter key.

  2. Press UP or DOWN using navigation keys to view the different submenus. Press Enter to access and Esc navigation key to return to the System menu screen.

  • Container ID: Sets the container identification number. Enter up to 11 characters (numbers or letters).

  • SW Unit Type: Select the unit type depending the product.

  • Refrigerant: Option to set unit refrigerant type.

  • Expansion Type: Show the option to select evaporator expansion valve and thermostatic expansion valve.

  • 20 FT. Unit: Tells the controller that this is the option chosen.

  • Container Length: Option to se container length.

  • Container Height: Option to se container height.

  • Modbus Slave: Select ON/OFF.

  • Reg. Sensor Type: Display the different temperature sensor that are mounted.

  • Unit Serial: The TK serial number of the unit itself. This is a ten digit alphanumeric entry found under the UNIT Serial Number on the Serial Plate on the unit.

  • Unit ID: A 12 digit alphanumeric unit serial number (old system).

  • Controller ID: View and edit the Controller ID.

Container ID SW Unit Type
Refrigerant Expansion Type
20 FT. Unit Container Length
Modbus Slave Reg. Sensor Type
Unit Serial Unit ID
Unit Serial Unit ID
Controller ID

Time & Date

Displays current Date and Time, which can be edited.

  1. Press the Enter key. Press the Down key to scroll down to the CONIG Menu.

  2. Press the Enter key to access the CONFIG menu.

  3. Select Time & Date menu.

  4. Press the Enter key to access the Time & Date screen.

  5. Press the Enter key to edit.

  6. Enter new time by: Using Up/Down to change the digits and by pressing F1 navigation key to move the cursor on to the next digit.

  7. Enter new Date by: Using Up/Down to change the digits and by pressing F1 navigation key to move the cursor on to the next digit.

  8. Once you have scrolled the cursor through all the time and date digits, press the Enter key to save.

  9. Press the Esc key to exit the Time & Date screen.

Calibrate

  1. Select Calibrate menu and press enter key.

  2. Press UP or DOWN keys to calibrate sensor probes. Press Enter to access and Esc navigation key to return to the CONFIG menu screen.

For Cld Treatment refer to Cold Treatment (CT).