Compressor Digital Control Valve Replacement
Removal
-
Isolate the compressor and digital valve from the system.
-
Front seat the discharge service valve by turning the valve fully clockwise.
-
Front seat the suction service valve by turning the valve fully clockwise.
-
Turn the digital service valve one quarter turn to the right.
-
-
Turn the Unit On/Off switch Off.
-
Disconnect electrical connections to valve coil.
-
Unsolder the liquid line connections to the valve.
-
Remove the valve from the unit.
Installation
-
Clean the tubes for soldering.
-
Place the new valve in position and solder the liquid line connections.
-
Perform a leak test (Refer to Leak Testing Refrigeration System). Repair leak if required.
-
Check the refrigerant charge (Refer to Checking Refrigerant Charge).
-
Reconnect the electrical wires to the valve.
-
Perform a controller pretrip test to verify system operation.