Standard Display
The Standard Display is a ¼ VGA graphical type display. The temperature can be displayed in Celsius or Fahrenheit.
The Standard Display will display the controlling sensor and Setpoint. The Setpoint will be the low reading with the C or F.
Once a key is pressed, the Standard Display will change to the Unit Status Display. After two minutes of no key activity, the display will return to the Standard Display.
Idle Screen and Check Symbol
After approximately 30 seconds of inactivity, the display will go into hibernation and one of the following symbols will be displayed. Display alternates between the idle screen and the standard display during this time.
Happy face = everything is OK | |
Disgruntled face = there is a message | |
Unhappy face = there is an alarm |
The check symbol indicates that a Smart PTI has recently been running and no problems were found. The checkmark will only be shown in the normal operation state. This symbol will appear at the left hand corner of the idle screen display.
Unit Status Display
The Unit Status Display will show the following (looking from top to bottom):
Display Icons
Mode Descriptions
Frozen/Cooling Down
Frozen/cooling down mode where the unit setpoint is set to below -10C. The function here is to maintain setpoint temperature by controlling the temperature on the return air.
The condenser fan will operate in on. The evaporator fans will operate in low speed mode.
Defrost
Defrost is a situation where the unit either on demand or timing is defrosting the evaporator coil. The unit is heating with the heating elements awaiting 18C on the evaporator sensor.
When the set Defrost termination temperature is reached, the unit will return to the operation mode depending on the setpoint.
PTI
PTI is a pretrip inspection and is used to diagnose the condition of the unit. There are a possibility to chose between several type of PTI´s depending on the test needed to secure the functionality of the unit.