Configuration Menu

The Configuration menu displays a list of functions that identifies unit operating features and current settings. A complete listing of the controller Configuration menu is located on an 11” x 17” foldout in the Diagrams chapter ().

With the unit turned On, allow it to start and stabilize and the display showing the unit status display:

  1. Press the F4 MENU key. Press the F3 key to scroll down to the CONFIG menu.

  2. Press the F4 key to expand this menu.

  3. Press the F2 OR F3 UP/DOWN key to scroll to view or reset the desired function.

  4. To set a new Configuration screen value:

    1. Press the F4 key with cursor in the desired menu line.

    2. Press the F2 OR F3 UP/DOWN key to scroll the value to the desired setting.

    3. Press the F4 key and release when the entry is complete. Press the F1 key. The new value appears in the menu line.

  5. Repeat steps 3 and 4 to reset additional configuration values.

  6. Press the F1 key to exit the Configurations screen.

Note Pressing F4 again will display the Overview screen.

Configuration Menu

Unit

Unit Menu and Unit Overview

  • In-Range Temperature limit: Sets the temperature value for the controller’s in-range LED and datalogger functions (factory default = 1.5 C [2.7 F]). Enter a value from 0.5 to 5.0 C (0.9 to 8.9 F).

  • Padlock Option : Select ON/OFF.

  • Log Interval: Sets the data log interval (1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 2 hours, 4 hours).

Options

This menu is used to turn ON/OFF a Module/Feature, select a particular option within a module, and tell the controller when a sensor is mounted.

  • Heater Type: Select from Extended Capacity and Normal Capacity

  • Condenser Fan Type: condenser fan type 2, ¾ and ½ HP

  • Evaporator Fan Type: evap motor selection 2 or 3

  • High Temp Suction Press Sensor: HT system LP pressure transducer mounted or none

  • Low Temperature Discharge Press Sensor: LT system HP pressure transducer mounted or none

  • Condenser Temperature Sensor: condenser sensor fitted “on or off”

System

System

  • Container ID: Sets the container identification number. Enter up to 11 characters (numbers or letters).

  • SW Unit Type: Choose Unit Type

  • Container length: 10, 20, 40, 43 or 45ft.

  • Container height: Select Standard or High Cube

  • Unit Serial ID: The TK serial number of the unit itself. This is a ten digit alphanumeric entry found under the UNIT Serial Number on the Serial Plate on the unit.

  • Unit ID: A 12 digit alphanumeric unit serial number (old system).

  • Controller ID: View and edit the Controller ID.

  • Power Module ID: An 8 digit alphanumeric number found on the power module.

Clock

Displays current Date and Time, which can be edited.

  1. Press the F4 key. Press the F3 key to scroll down to the CONFIGURATION Menu.

  2. Press the F4 key to access the CONFIGURATION menu. Press the F3 key to scroll down to the Clock Menu.

  3. Press the F4 key to access the Date & Time screen.

  4. Press the F4 key to edit.

  5. Enter new time by: Using F2 or F3 Up/Down to change the digits and by pressing F4 to move the cursor on to the next digit.

  6. Once you have scrolled the cursor through all the time and date digits, you get an option to Press the F4 key to save. Press and hold F4 until the main menu appears.

  7. Press the F1 key to exit the Date & Time screen.

Icon Menu

  1. Press the F2 or F3 UP/DOWN key to scroll to the Configuration selection and press the F4 key. The Configuration Menu will appear.

  2. Press the F2 or F3 UP/DOWN key to scroll to the Icon Menu selection and press the F4 key. The Icon Menu will appear as shown below.

To change back to the Classic Menu:

  1. Press the F4 key to display the Icon Menu.

  2. Press the F2 or F3 UP/DOWN key to scroll to the Config selection.

  3. Press the F4 key. The Configuration Menu will appear.

  4. Press the F2 or F3 UP/DOWN key to scroll to the Classic Menu selection.

  5. Press the F4 key. The Classic Menu will appear.