Specifications
Engine
Note New diesel engine models started being installed in units beginning
the 4th quarter of 2020. Some engine components along with maintenance
and inspection procedures are different between engine models. Refer
to the information located on top of the engine to determine which
model engine is in your unit, or contact your Thermo King Dealer for
assistance.
|
|
Model/Engine | C-600:
TK486V25 changed to TK486V25L1 4th quarter 2020. S-600: TK488CR changed to TK488CR1 2nd quarter 2021. S-700: TK488CRH changed to TK488CRH1 2nd quarter 2021. |
Fuel Type | TK486V25
and TK486V25L1: No. 2 diesel fuel under normal conditions No. 1 diesel fuel is acceptable cold weather fuel TK488CR, TK488CR1, TK488CRH and TK488CRH1: |
Oil Capacity | 12
quarts (11.4 liters) crankcase and oil filter. Fill to full mark on dipstick |
Oil Type | TK486V25
and TK486V25L1: Requires API Classification CJ-4 or better. ACEA Rating
E6. FA-4 (10w-30 only). TK488CR, TK488CR1, TK488CRH and TK488CRH1: Requires API Classification CJ-4 or better. ACEA Rating E6. FA-4 (10w-30 only). Note This oil type must be used
together with ULSD fuel.
|
Recommended oil viscosity based on ambient temperature | 14
to 122 F (-10 C to 50 C): SAE 15W-40 (Synthetic) 5 to 104 F (-15 to 40 C): SAE 15W-40 5 to 104 F (-15 to 40 C): SAE 10W-30 (Synthetic or Synthetic Blend) -13 to 104 F (-25 to 40 C): SAE 10W-40 -13 to 86 F (-2 to 30 C): SAE 10W-30 -22 to 122 F (-30 to 50 C): SAE 5W-40 (Synthetic) Below -22 F (-30 C): SAE 0W-30 (Synthetic) |
Engine Coolant Type |
Chevron/Delo XLC - a nitrite-free Extended Life Coolant (ELC) Use a 50/50 concentration |
|
|
Coolant System Capacity | 7.5 quarts (7.1 liters) |
Radiator Cap Pressure | 15 psig (103 kPa) |
Engine Coolant Thermostat | 160 F (71 C) |
Refrigeration System
Contact your Thermo King dealer for refrigeration system service or maintenance.
Electrical Control System
Low Voltage | 12.5 Vdc |
High Voltage | 200-210 Vac from AC generator at engine low speed. 345 Vac from AC generator at engine high speed. |
Battery | One, Group C31, 12 volt battery. The battery must be suitable
for deep cycling, heavy duty and rated with a minimum of 95 amp/hr. Thermo King ReliaMax 925N (925 CCA) wet cell battery is recommended for both warm and cold climates. Thermo King EON (1150 CCA) AGM battery is recommended for extreme climates and for Rail Ready (RR), Domestic Refrigerated Container (DRC), and Trailer on Flat Car (TOFC) applications. Note If the unit is not going to be used for an extended
period of time, turn the Microprocessor On/Off Power Switch to the
OFF position to maximize battery life.
|
Fuses | Refer to Fuses (Unit Protection Devices). |
Battery Charging | 12 volt, 37 amp, brush type, Thermo King Alternator. |
Electrical Standby (SmartPower Unit Only)
Note A transformer is used to
convert 460 Vac to 230 Vac for the condenser and evaporator fan motors
in units configured to use electric standby input voltage of 460 Vac.
Electric Motor and Overload Relay
Voltage/Phase/Frequency | Horsepower | Kilowatts | RPM | Full Load (amps) | Overload Relay Setting (amps) |
---|---|---|---|---|---|
230/3/60 | 12.0 | 9.0 | 1760 | 31.2 | 34 |
460/3/60 | 12.0 | 9.0 | 1760 | 15.6 | 20 |
460/3/60 | 19.0 | 14.2 | 3500 | 21.7 | 32 |
Standby Power Cord Requirements (SmartPower Units Only)
Supply Circuit Breaker | 230/3/60 (12 hp motor)– 50 amps (1) 460/3/60 (12 hp motor) – 30 amps (1) 460/3/60 (15/16 hp motor) – 30 amps (1) 460/3/60 (19 hp motor) – 50 amps (1) |
Extension Cord Size | 230/3/60 (12 hp
motor) – Type W, 8 AWG (2) 460/3/60 (12 hp motor) – Type W or SOOW, 10 AWG (2) 460/3/60 (15/16 hp motor) – Type W or SOOW, 10 AWG (2) 460/3/60 (19 hp motor) – Type W, 8 AWG Power Cable (2) |
(1) HACR/Motor Circuit Breaker Recommended, Consult a Licensed Electrician (2) 25 ft (7.5m) permitted without cable management, 75 ft. (22.8 m) Max recommended permitted with approved cable management system |