Using the Sensors Key
The SENSORS Key allows the operator to view the unit gauges. If the function of this key has been reassigned, the SENSORS Menu is also available in the Maintenance Menu.
To access the SENSORS Menu, press the SENSORS Key:
The first sensor display will appear. Press the NEXT and BACK Keys to scroll through the sensors. Pressing the LOCK Key will lock the current sensor on the display ( Next, Back, Lock Keys).
The sensors available are shown below.
To return to the Standard Display, press the EXIT Key.
Sensors Available
Control Return Air Temperature: Displays the temperature of the control return air sensor.
Display Return Air Temperature: Displays the temperature of the display return air sensor.
Control Discharge Air Temperature: Displays the temperature of the control discharge air sensor.
Display Discharge Air Temperature: Displays the temperature of the display discharge air sensor.
Temperature Differential: Displays the calculated difference between the control return air sensor and the control discharge air sensor.
Evaporator Coil Temperature: Displays the temperature of the evaporator coil sensor.
Ambient Air Temperature: Displays the temperature of the ambient air sensor.
* Spare 1 Temperature: Displays the temperature of the spare 1 temperature sensor.
* Log Sensor 1: Displays the temperature of the CargoWatch Data Logger temperature sensor 1.
* Log Sensor 2: Displays the temperature of the CargoWatch Data Logger temperature sensor 2.
* Log Sensor 3: Displays the temperature of the CargoWatch Data Logger temperature sensor 3.
* Log Sensor 4: Displays the temperature of the CargoWatch Data Logger temperature sensor 4.
* Log Sensor 5: Displays the temperature of the CargoWatch Data Logger temperature sensor 5.
* Log Sensor 6: Displays the temperature of the CargoWatch Data Logger temperature sensor 6.
Board Temperature Sensor: Displays the internal temperature of the HMI Control Panel pc board.
* If sensors have been added.