Changing the Setpoint - Numerical Setpoint
If the TemperatureWatch display is shown, press any soft key to return to the Standard Display. From the Standard Display, press the SETPOINT Key ( Setpoint Key).
The setpoint display appears ( Setpoint Display).
The -
and +
Keys are used to increase or decrease
the setpoint until the desired setpoint is shown. The setpoint has
been changed to 40 F using the +
Key ( Setpoint Changed Using +
Key).
The YES and NO Keys ( Yes and No Keys) confirm the setpoint change. When the desired setpoint
has been selected using the +
and/or -
Keys, press the
YES Key to confirm and load the new setpoint. If the setpoint is changed
using the +
or -
Keys, the change must be confirmed
or rejected by pressing the YES or NO Key within 10 seconds of changing
the setpoint. A warning beep will sound for five seconds as a reminder.
Failure to confirm the new setpoint by pressing Yes or No within 10 seconds of changing the setpoint will result in no setpoint change. In addition, Alarm Code 127 Setpoint Not Entered is set, to indicate that a setpoint change was initiated but not completed.
After the YES Key has been pressed, the display briefly shows PROGRAMMING NEW SETPOINT - PLEASE WAIT. The display then confirms the new setpoint for several seconds ( New Setpoint).
If the NO Key is pressed the display will briefly show SETPOINT NOT CHANGED and return to the Standard Display. The Standard Display will show the old setpoint.
The display then returns to the Standard Display showing the new setpoint. Notice that the arrow now points up to indicate that the unit is heating ( Up Arrow).
+or
-Keys, the change must be confirmed or rejected by pressing the YES or NO Key within 10 seconds of changing the setpoint.
-
If the YES Key is pressed, the setpoint change made with the
+
or-
Key is accepted, the setpoint changes, and the display returns to the Standard Display. -
If the NO Key is pressed the setpoint change made with the
+
or-
Key is not accepted, the setpoint is not changed, and the display returns to the Standard Display. -
If the YES or NO Key is not pressed within 10 seconds of making a change with the
+
or-
Key, the setpoint is not changed and the display returns to the Standard Display. The display briefly shows [SETPOINT NOT CHANGED] and Alarm Code 127 Setpoint Not Entered is set, to indicate that a setpoint change was initiated but not completed.
See Changing the Setpoint - Numerical Setpoint () for an overview of the procedure.