Pre-trip Testing

Allows the User to test the genset for ability to perform a self-diagnostic test prior to sending the unit out for operation. The test verifies no operational issues prior to Genset being put into service

  1. PTI is initiated by pressing and holding the F1 button while unit is waiting to start.

  2. When initiated, the controller will begin the engine start sequence from the beginning of the buzzer alert .

  3. Genest is to bypass the 2 mins excitation delay and then test the high and low speed operation of the genset. The controller shall also test generator output voltage at those speeds.

  4. Pass = Controller to receive appropriate run confirmation from the Yanmar ECU, the generator and any internal DSE specific operations

  5. Fail = Lack of receipt of appropriate run confirmation from the Yanmar ECU, the generator and any internal DSE specific operations

  6. All items in the below Manual function test sub menu shall be validated and logged for “Pass” or “Fail