Controller Display Menu
User to be able to Cycle through the top-level tab structure using the ←/→ arrows and view the displayed information by using the ↑ / ↓ arrows
The Data tab displays general unit operating information including electrical data, temperatures, etc. It contains the following submenus:
-
Status
-
Engine
-
Generator
-
Alarms
-
ECU Current DTC’s
-
Event Log
-
Serial Port
-
Genset Information
-
PLC instruments
-
About
Status
Displays a summary of electrical output
These lines are not ‘selectable ‘. Data is readable only
Status tab submenu information:
-
On Load
-
Voltage
-
Frequency
Engine
Displays Engine and System information and status
User to be able to Cycle through the menu using the ↑ / ↓
These lines are not ‘selectable ‘. Data is readable only
Engine tab submenu information:
-
Engine Speed
-
Coolant Temperature
-
Battery Voltage
-
Engine Run Time
-
WiF Status
-
Engine percentage load
-
Engine Link
-
Can bus information
Generator
The Generator submenu display the status of the following outputs:
Displays Generator information, status and configuration
User to be able to Cycle through the menu using the ↑ / ↓
These lines are not ‘selectable ‘. Data is readable only
Generator tab submenu information:
-
Generator Voltage
-
Generator Frequency
-
Generator Phase Sequence
-
Active Configuration (Volts)
Alarms
Displays a list of the current logged alarms
User to be able to Cycle through the menu using the ↑ / ↓
These lines are not ‘selectable ‘. Data is readable only
The Alarm List Menu displays alarms. Alarms are recorded in the controller memory to simplify unit diagnostic procedures. The alarms are listed in the reverse order of their occurrence.
Active ECU DTC’s Menu
Displays a list of the current logged Engine Diagnostic Trouble Codes
User to be able to Cycle through the menu using the ↑ / ↓
These lines are not ‘selectable ‘. Data is readable only
Event Log
Displays the unit event log
User to be able to Cycle through the menu using the ↑ / ↓
These lines are not ‘selectable ‘. Data is readable only
Serial Port Menu
Displays Serial Port information and condition
User to be able to Cycle through the menu using the ↑ / ↓
These lines are not ‘selectable ‘. Data is readable only
Genset Data Menu and Config Details
Displays System Configuration
User to be able to Cycle through the menu using the ↑ / ↓
Allows the user to specify / modify various system conditions. All data is manually entered
PLC Instrumentation
Displays PLC Settings and condition
User to be able to Cycle through the menu using the ↑ / ↓
These lines are not ‘selectable ‘. Data is readable only
-
Restart Timer
-
Timer Countdown
-
Timer Total (Default 20)
-
-
Low Speed Hours
-
High Speed Hours
-
Restart Attempts
-
Restarts attempted
-
Restart total (Default 3)
-
About
Displays Software information and revision.
User to be able to Cycle through the menu using the ↑ / ↓
These lines are not ‘selectable ‘. Data is readable only
-
Variant Version
-
Application Version
-
USB ID
-
Bootloader Version
-
Analogue Version
-
Engine Type
-
Version