Electrical Control System
Controls | SG–3500 Controller | |
Voltage | 12.5 Vdc (nominal) | |
Battery | 12 Volts, Group 31, 925 / 950 CCA @ -18 C (0 F) | |
Fuse FS1 (Located in Control Box) | 10 Amp - Battery Post to Main Relay | |
Fuse FS2 (Located in Control Box) | 40 Amp - Battery Post trough ON/OFF switch to SW Post | |
Fuse FS3 (Located in Control Box) | 60 Amp - Starter Fuse | |
Fuse FS4 (Located in Control Box) | 80 Amp - Air Heater Fuse | |
Fuse FS5 (Located in Control Box) | 2 Amp - Battery Post to Telematics | |
Fuse FS6 (Located in Control Box) | 2 Amp - SW Post to Telematics | |
Electrical Components NOTE: Disconnect components from unit circuit to check resistance. |
||
Current Draw (Amps) at 12.5 Vdc | Resistance — Cold (Ohms) | |
Starter Motor | 350-475* | |
* On-the-engine cranking check. Bench test is approximately 140 amps. |