Electrical Control System

Controls   SG–3500 Controller
Voltage   12.5 Vdc (nominal)
Battery   12 Volts, Group 31, 925 / 950 CCA @ -18 C (0 F)
Fuse FS1 (Located in Control Box)   10 Amp - Battery Post to Main Relay
Fuse FS2 (Located in Control Box)   40 Amp - Battery Post trough ON/OFF switch to SW Post
Fuse FS3 (Located in Control Box)   60 Amp - Starter Fuse
Fuse FS4 (Located in Control Box)   80 Amp - Air Heater Fuse
Fuse FS5 (Located in Control Box)   2 Amp - Battery Post to Telematics
Fuse FS6 (Located in Control Box)   2 Amp - SW Post to Telematics

Electrical Components

NOTE: Disconnect components from unit circuit to check resistance.

  Current Draw (Amps) at 12.5 Vdc Resistance — Cold (Ohms)
Starter Motor 350-475*  
* On-the-engine cranking check. Bench test is approximately 140 amps.