Manual Function Test

The Manual Function Test submenu contains the following component tests:

  • Display Test

  • RLI ECU Ignition Test

  • RL2 ECU Run Relay Test

  • RL3 ECU Fuel Relay Test

  • RL5 DSR Test

The test result (PASSED of FAILED) is displayed after a test is performed. To enter the Manual Function Test complete the following steps:

  1. Place the On/Off switch in the “ON” position.

  2. Press the ENTER key or the ESCAPE key to enter the Main Menu, if necessary.

  3. Press the UP or DOWN key to scroll up or down through the Main Menu to the Commands Menu.

  4. Press the ENTER key to enter the Commands Menu.

  5. The PTI submenu will be displayed.

  6. Press the UP or DOWN key to scroll up or down through the Commands Menu to the Manual Function Test submenu.

  7. Press the ENTER key to enter the Manual Function Test.

    • The engine will stop if it is running.

    • The Display Test is the first to appear. Press the ENTER key to perform the Display Test.

    • Press the UP or DOWN key to scroll up or down through the Manual Function Test submenu. Press the ENTER key to perform the selected test.

    • Press the ESCAPE key to return to the Commands Menu.

Manual Function Test Example