SGCO Clip-on Corner Clamp Unit Installation

    Caution
  • Risk of Injury
  • Take adequate precautions when lifting and mounting the generator set to prevent personal injury or unit damage.
    Caution
  • Service Procedure
  • Excessive vibration or unit malfunction can occur if mounting clamps are not properly secured. The generator set MUST be tight against the container.

1. Unit Mounting Bracket Assembly (one per side) 5. Lock Nut
2. Clamp Shaft 6. Washer
3. Clamp Paw 7. Lower Mounting Bolt
4. Clamp Handle 8. Door

  1. Loosen the locking nut (5) so the clamp shaft (2) can extend to the rear of the unit.

  2. Pull the clamp pawl handle (3) towards the front of the unit to unlock the clamp handle (4).

  3. Lift the clamp handle (4) upwards to rotate the clamp shaft foot (2) 90 degrees upwards.

  4. Let the clamp pawl (3) drop down to hold the clamp handle (4) in position.

  5. Use appropriate heavy equipment to lift the unit into mounting position on front wall of the container. The foot of the mount clamp (5) should fit into corner casting on each side of the container.

  6. Ensure the angled foot of the clamp shaft (5) fits properly into the container corner casting on each side of the unit.

  7. Pull lock pawl handle (3) towards the front of the unit to unlock the clamp handle (4).

  8. Pull the clamp handle (4) downward to rotate the clamp shaft (2) 90° and clamp generator set to container.

  9. Release the clamp pawl handle (3) so it is back into locking position and holds the clamp handle (4) in the locked (down) position.

  10. Ensure the generator set frame fits tightly against the container. Turning the mounting clamp handle should pull the generator set frame tight against the container corner casting. Be sure the clamp boss (shown below) is sitting inside the container corner casting hole. The clamp shaft can be tightened or loosened by turning the nut on the head of the clamp shaft.

    1. Clamp Boss
  11. Tighten the locking nut (5) with hand wrench. The mounting clamp can be tightened or loosened by turning the lock nut (5) on the head of the clamp shaft.

  12. Install the lower mounting bolts:

    1. Open door flap. Remove lower mounting bolts from storage tube. Install bolts into the container post.

    2. Tighten the lower mounting bolts to 300 to 380 Nm (220 to 280 ft-lb).

    3. Close the door flap.