EcoPower

EcoPower is an standard feature on all SG 5000 units - designed to save fuel and meet emissions regulations. The controller monitors the load from the refrigeration unit and determines if the engine should run in high speed (1800 ± 10 RPM), or low speed (1500 ± 5 RPM). The output frequency is 60 Hz in high speed and 50 hz in low speed. The engine runs in high speed for at least fifteen minutes when it is started, and whenever it shifts from low speed to high speed (ECU controlled).