SGCO Clip-on Corner Header Pin Unit Installation

  1. Lift the unit into mounting position on front wall of the container. Both header pins of generator set mounting channel should fit into mounting holes on top of the container.

      Caution
    • Risk of Injury
    • Take adequate precautions when lifting and mounting the generator set to prevent personal injury or unit damage.

  2. Check to be sure the generator set frame fits tightly against the container.

      Caution
    • Service Procedure
    • Excessive vibration or unit malfunction can occur if mounting clamps are not properly secured. The generator set MUST be tight against the container.

  3. Install the lower mounting bolts:

    1. Open door flap. Remove lower mounting bolts from storage tube. Install bolts into the container post.

    2. Tighten the lower mounting bolts to 300 to 380 Nm (220 to 280 ft-lb).

    3. Close the door flap.