Controller Replacement

  1. Turn the Unit ON/OFF switch OFF.

  2. Turn the unit 460/380V main circuit breaker off.

      危险
    • 危险电压
    • 断开控制器的连接后,如果主电源模块存在 460/380 V 的电源,设备将自动启动并运行。 在更换控制器之前先断开设备的电源,以防旋转电机或高压控件的危险电击对人体造成伤害。

  3. Disconnect the unit power cord from the power supply.

  4. At the same time, remove the controller from the door.

  5. Install the replacement controller in the door.

  6. Connect the keyboard cable to the controller.

  7. Connect the Harness to the controller.

  8. Recheck all connector plugs to verify they are fully seated.

  9. Review the Configuration Menu instructions in the operating section. Reset information as required.

  10. Review the Miscellaneous Functions Menu instructions in the operating section. Reset information as required.

    注意
  1. Enter the container ID before releasing the unit for service. The container ID is required to identify the data downloaded from the controller datalogger.

  2. Several programmable features may need to be set to completely configure the unit to customer specifications. Adjust any additional programmable settings to customer requirements before releasing the unit for service.