Evaluation of the Qualification Test
T-1200R Spectrum S3+S3 - Multi-temperatures Tests
Multi-Temperatures Operation - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length (Zone 1)
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C | +20°C | +17/+22 °C | +19 °C | -2 /+1°C of setpoint |
+20°C | +17/+22 °C | +20 °C | -2 /+1°C of setpoint | |
+6°C | +2/+8 °C | +6 °C | -2 /+1°C of setpoint | |
-30°C | +20°C | +15/+21 °C | +18 °C | -2 /+1°C of setpoint |
+20°C | +15/+23 °C | +17 °C | -5 /+0°C of setpoint | |
+6°C | +2/+8 °C | +5 °C | -3 /+2°C of setpoint |
Multi-Temperatures Operation - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length (Zone 2)
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+6°C |
+3/+8 °C |
+6°C |
- /+1°C of setpoint |
-25°C |
-27/-21 °C |
-25°C |
-1 /+2°C of setpoint |
|
-25°C |
-27/-20 °C |
-24°C |
0 /+3°C of setpoint |
|
-30°C |
+6°C |
+4/+7 °C |
+6°C |
-1/+2°C of setpoint |
-25°C |
-28/-24 °C |
-26°C |
-2 /+0°C of setpoint |
|
-25°C |
-29/-21 °C |
-26°C |
-2 /+1°C of setpoint |
Door opening - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length
Ambient | Setpoint | 5 minutes rear door opening | 10 minutes rear doors opening | |||
Zone 1 | Zone 2 | Air temperature peak (Z2) | Recovery time after closing doors | Air temperature peak (Z2) | Recovery time after closing doors | |
+40°C | +20°C | +6°C | +33.9 °C | 11 minutes | +37.3 °C | 22 minutes |
+20°C | -25°C | +29.7 °C | 87 minutes | - | - | |
+6°C | +20°C | +36 °C | 5 minutes | +37.7 °C | 6 minutes | |
-25°C | +6°C | +32.9 °C | 17 minutes | +35.8 °C | 18 minutes | |
-25°C | +20°C | +35.3 °C | 4 minutes | +38.4 °C | 4 minutes | |
-30°C | +20°C | +6°C | -24.4 °C | 16 minutes | -27.3 °C | 23 minutes |
+20°C | +20°C | -20.9 °C | 25 minutes | -25.8 °C | 39 minutes | |
+6°C | +20°C | -21.1 °C | 19 minutes | -26.9 °C | 27 minutes | |
+6°C | +6°C | -23.6 °C | 9 minutes | -26.8 °C | 14 minutes |
Failure Test - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length
Ambient | Zone 1 | Zone 2 | ||||
Setpoint | Time to move out of the range | Rules to apply | Setpoint | Time to move out of the range | Rules to apply | |
+40°C | +6°C | 10minutes | Above +8°C or max 2hrs. | +20°C | 2 hours | Above +25°C or max 2hrs. |
+6°C | 8 minutes | Above +8°C or max 2hrs. | -25°C | 15 minutes | Above -20°C or max 2hrs. | |
-25°C | 11 minutes | Above -20°C or max 2hrs. | +20°C | 2 hours | Above +25°C or max 2hrs. | |
-30°C | -25°C | N.A. | Non Applicable | +6°C | 7 minutes | Below +2°C or max 2hrs. |
-25°C | N.A. | Non Applicable | +20°C | 4 minutes | Below +15°C or max 2hrs. | |
+20°C | 20 minutes | Below +15°C or max 2hrs. | +6°C | 35 minutes | Below +2°C or max 2hrs. |
T-1200R Spectrum S3+S3 - Single-temperature Tests
Single Temperature Operation - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+20°C |
+16/+21 °C |
+19 °C |
-2 / 0°C of setpoint |
+6°C |
+2/+8 °C |
+5 °C |
-2 / 0°C of setpoint |
|
-25°C |
-27/-20°C |
-24 °C |
0 /+2°C of setpoint |
|
-30°C |
+20°C |
+16/+22 °C |
+19 °C |
-3 / 0°C of setpoint |
+6°C |
+2/+8 °C |
+5 °C |
-2 / 0°C of setpoint |
|
-25°C |
-31/-25 °C |
-28 °C |
-4 /-1°C of setpoint |
Door opening - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient | Setpoint | 5 minutes rear door opening | 10 minutes rear doors opening | ||
Air temperature peak (Z2) | Recovery time after closing doors | Air temperature peak (Z2) | Recovery time after closing doors | ||
+40°C | +20°C | +36.5 °C | 6 minutes | +38 °C | 8 minutes |
+6°C | +34.2 °C | 30 minutes | +36.5 °C | 41 minutes | |
-25°C | +31.7 °C | 117 minutes | - | - | |
-30°C | +20°C | -24.5 °C | 34 minutes | -26 °C | 55 minutes |
+6°C | -26 °C | 24 minutes | -28.2 °C | 34 minutes |
Failure Test - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient |
Setpoint |
Time to move out of the range |
Rules to apply |
+40°C |
+6°C |
20 minutes |
Above +8°C or max 2hrs. |
-25°C |
15 minutes |
Above -20°C or max 2hrs. |
|
-30°C |
+20°C |
11 minutes |
Below +15°C or max 2hrs. |
+6°C |
20 minutes |
Below +2°C or max 2hrs. |
T-1000R Spectrum S3+S3 - Multi-temperatures tests
Multi-Temperatures Operation - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length (Zone 1)
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+20°C |
+17/+22 °C |
+20 °C |
-2 / 0°C of setpoint |
-30°C |
+20°C |
+16/+21 °C |
+18 °C |
-3 / 0°C of setpoint |
Multi-Temperatures Operation - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length (Zone 2)
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+6°C |
+3/+8 °C |
+6 °C |
- / +1°C of setpoint |
-30°C |
+6°C |
+4/+7 °C |
+5 °C |
-2 / 0°C of setpoint |
Door Opening - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length
Ambient | Setpoint | 5 minutes rear door opening | 10 minutes rear doors opening | |||
Zone 1 | Zone 2 | Air temperature peak (Z2) | Recovery time after closing doors | Air temperature peak (Z2) | Recovery time after closing doors | |
+40°C |
+20°C |
+6°C |
+34.2 °C |
19 minutes |
+36.7 °C |
24 minutes |
+6°C |
+20°C |
+36.7 °C |
4 minutes |
+37.9 °C |
5 minutes |
|
-30°C |
+6°C |
+20°C |
-20.7 °C |
34 minutes |
-25.5 °C |
59 minutes |
+20°C |
+6°C |
-24.4 °C |
15 minutes |
-27.9 °C |
24 minutes |
Failure test - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length
Ambient | Zone 1 | Zone 2 | ||||
Setpoint | Time to move out of the range | Rules to apply | Setpoint | Time to move out of the range | Rules to apply | |
+40°C |
+6°C |
8 minutes |
Above +8°C or max 2hrs. |
+20°C |
2 hours |
Above +25°C or max 2hrs. |
+20°C |
2 hours |
Above +25°C or max 2hrs. |
+6°C |
10 minutes |
Above +8°C or max 2hrs. |
|
-30°C |
+6°C |
86 minutes |
Below +2°C or max 2hrs. |
+20°C |
36 minutes |
Below +15°C or max 2hrs. |
+20°C |
35 minutes |
Below +15°C or max 2hrs. |
+6°C |
65 minutes |
Below +2°C or max 2hrs. |
T-1000R Spectrum S3+S3 - Single-temperature Tests
Single Temperature Operation - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+20°C |
+16/+21 °C |
+19 °C |
-2 / 0°C of setpoint |
+6°C |
+2/+8 °C |
+5 °C |
-2 / 0°C of setpoint |
|
-30°C |
+20°C |
+16/+22 °C |
+19 °C |
-3 / 0°C of setpoint |
+6°C |
+2/+8 °C |
+5°C |
-2 / 0°C of setpoint |
Door opening - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient | Setpoint | 5 minutes rear door opening | 10 minutes rear doors opening | |||
Air temperature peak (Z2) | Recovery time after closing doors | Air temperature peak (Z2) | Recovery time after closing doors | |||
+40°C |
+20°C |
+36.5 °C |
6 minutes |
+38 °C |
8 minutes |
|
+6°C |
+34.2 °C |
30 minutes |
+36.5 °C |
41 minutes |
||
-30°C |
+20°C |
-24.5 °C |
34 minutes |
-26 °C |
55 minutes |
|
+6°C |
-26 °C |
24 minutes |
-28.2 °C |
34 minutes |
Failure Test - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient | Setpoint | Time to move out of the range | Rules to apply |
+40°C | +6°C | 20 minutes | Above +8°C or max 2hrs. |
-30°C | +20°C | 11 minutes | Below +15°C or max 2hrs. |
+6°C | 20 minutes | Below +2°C or max 2hrs. |
UT-1200 Spectrum S3+S3 - Multi-Temperatures Tests
Multi-Temperatures Operation - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length (Zone 1)
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+20°C |
+17/+22 °C |
+20 °C |
- / +1°C of setpoint |
-30°C |
+20°C |
+15/+22 °C |
+18°C |
-3 / 0°C of setpoint |
Multi-Temperatures Operation - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length (Zone 2)
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+5°C |
+2/+8 °C |
+6 °C |
-1 / +2°C of setpoint |
-30°C |
+5°C |
+3/+7 °C |
+4°C |
-4 / 0°C of setpoint |
Door opening 5 minutes - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length
Ambient | Zone 1 (side door) | Zone 2 (rear doors) | ||||
Setpoint | Air temperature peak | Recovery time after closing doors | Setpoint | Air temperature peak | Recovery time after closing doors | |
+40°C |
+5°C |
+31.8°C |
9 minutes |
+20°C |
+30.9°C |
4 minutes |
+20°C |
+35.6°C |
4 minutes |
+5°C |
+25.7°C |
20 minutes |
|
-30°C |
+5°C |
-27.5°C |
18 minutes |
+20°C |
-13.8°C |
29 minutes |
+20°C |
-25.3°C |
25 minutes |
+5°C |
-17.3°C |
37 minutes |
Door opening 10 minutes - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length
Ambient | Zone 1 (side door) | Zone 2 (rear doors) | ||||
Setpoint | Air temperature peak | Recovery time after closing doors | Setpoint | Air temperature peak | Recovery time after closing doors | |
+40°C |
+5°C |
+37.8°C |
13 minutes |
+20°C |
+35.3°C |
8 minutes |
+20°C |
+38.5°C |
6 minutes |
+5°C |
+34°C |
25 minutes |
|
-30°C |
+5°C |
-29.6°C |
35 minutes |
+20°C |
-20.1°C |
55 minutes |
+20°C |
-29.8°C |
45 minutes |
+5°C |
-25°C |
55 minutes |
Failure test - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length
Ambient | Zone 1 | Zone 2 | ||||
Setpoint | Time to move out of the range | Rules to apply | Setpoint | Time to move out of the range | Rules to apply | |
+40°C |
+5°C |
18 minutes |
Above +8°C or max 2hrs. |
+20°C |
2 hours |
Above +25°C or max 2hrs. |
+20°C |
102 minutes |
Above +25°C or max 2hrs. |
+5°C |
15 minutes |
Above +8°C or max 2hrs. |
|
-30°C |
+5°C |
13 minutes |
Below +2°C or max 2hrs. |
+20°C |
15 minutes |
Below +15°C or max 2hrs. |
+20°C |
15 minutes |
Below +15°C or max 2hrs. |
+5°C |
7 minutes |
Below +2°C or max 2hrs. |
UT-1200 Spectrum S3+S3 - Single-temperature Tests
Single Temperature Operation - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+20°C |
+17/+23 °C |
+20 °C |
-1 / 0°C of setpoint |
+5°C |
+2/+7 °C |
+5°C |
- / +1°C of setpoint |
|
-30°C |
+20°C |
+15/+21 °C |
+19 °C |
-1°C of setpoint |
+5°C |
+2/+6 °C |
+4°C |
-3 / 0°C of setpoint |
Door open - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient | Setpoint | 5 minutes rear door opening | 10 minutes rear doors opening | ||
Air temperature peak | Recovery time after closing doors | Air temperature peak | Recovery time after closing doors | ||
+40°C |
+20°C |
+30.4 °C |
3 minutes |
+35.7 °C |
7 minutes |
+5°C |
+25.9 °C |
17 minutes |
+33.2 °C |
25 minutes |
|
-30°C |
+20°C |
-9.4 °C |
16 minutes |
-21.9 °C |
46 minutes |
+5°C |
-15.3 °C |
16 minutes |
-25.6 °C |
28 minutes |
Failure test - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and wall stowed
Ambient | Setpoint | Time to move out of the range | Rules to apply |
+40°C |
+5°C |
19 minutes |
Above +8°C or max 2hrs. |
+20°C |
8 minutes |
Above -20°C or max 2hrs. |
|
-30°C |
+20°C |
16 minutes |
Below +15°C or max 2hrs. |
+5°C |
8 minutes |
Below +2°C or max 2hrs. |
UT-R Spectrum S3+S3 - Multi-Temperatures Tests
Multi-Temperatures Operation - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length (Zone 1)
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+5 °C |
+2.6 °C / +6.9 °C |
+ 4.9 °C |
-1.2 / +1 °C of setpoint |
+20 °C |
+17.5 °C / +20.9 °C |
+ 20 °C |
-1.5 / +0.3 °C of setpoint |
|
-30°C |
+5 °C |
+3.6 °C / +6 °C |
+5 °C |
-0.8 / +0.6 °C of setpoint |
+21 °C |
+17.1 °C / +21.6 °C |
+19.3 °C |
-3.2 / +0.2 °C of setpoint |
Multi-Temperatures Operation - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length (Zone 2)
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40°C |
+20 °C |
+17.6 °C / +22.9 °C |
+20.6 °C |
-0.6 / +1.7 °C of setpoint |
+5 °C |
+2.7 °C / +6.2 °C |
+5.2 °C |
-0.6 / +1 °C of setpoint |
|
-30°C |
+21 °C |
+16.9 °C / +22.7 °C |
+19.4 °C |
-3 / +0.5 °C of setpoint |
+5 °C |
+4.2 °C / +6 °C |
+5 °C |
-0.2 / +0.3 °C of setpoint |
Door opening - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length.
Ambient | Setpoint | 7minutes rear door opening | ||
Zone 1 | Zone 2 | Air temperature peak (Z2) | Recovery time after closing doors | |
+40°C |
+20 °C |
+6 °C |
+25.5 °C |
23 minutes |
-30°C |
+5 °C |
+21 °C |
-13.9 °C |
28 minutes |
+21 °C |
+5 °C |
-18.6 °C |
16 minutes |
Failure Test - Configuration as in GDP-TK-OQ-SP-MT figure 7, dividing wall in middle position of total length
Ambient | Zone 1 | Zone 2 | ||||
Setpoint | Time to move out of the range | Rules to apply | Setpoint | Time to move out of the range | Rules to apply | |
+40°C |
+20 °C |
> 2 hours |
Above +25 °C or max 2hrs. |
+6 °C |
8.5 minutes |
Above +8°C or max 2 hrs. |
-30°C |
+21 °C |
> 2 hours |
Above +25°C or max 2hrs. |
+5 °C |
16 minutes |
Below +2°C or max 2 hrs. |
UT-R Spectrum S3+S3 – Single Temperature tests
Single Temperature Operation - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient | Setpoint | Min/Max sensor temperature | Average temperature | Average temperature deviation |
+40 °C |
+20 °C |
+16.8 °C / +20.3 °C |
+19.1 °C |
-1.3 / +0 °C of setpoint |
+5 °C |
+2.4 °C / +6.8 °C |
+5.1 °C |
-0.5 / +0.5 °C of setpoint |
|
-23 °C |
-27.2 °C / -23.5 °C |
-25.5 °C |
-2.5 °C of setpoint |
|
+30 °C |
-29 °C |
-31.8 °C / +27.7 °C |
-29.8 °C |
-1.2 / -0.3 °C of setpoint |
-30 °C |
+20 °C |
+17.1 °C / +21.8 °C |
+19.7 °C |
-1.3/ +0.4 °C of setpoint |
+5 °C |
+3.4 °C / +6.6 °C |
+4.7 °C |
-1.0/ +0.4 °C of setpoint |
|
-24 °C |
-26.4 °C / -22.6 °C |
-24.7 °C |
-1.6/ +0.2 °C of setpoint |
|
-27°C |
-30.3 °C / -28.7 °C |
-29.6 °C |
-3.3 / -1.7 °C of setpoint |
Door openings - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and dividing wall stowed
Ambient | Setpoint | 7 minutes rear door opening | |
Air temperature peak | Recovery time after closing doors | ||
+40 °C |
+5 °C |
+24.2 °C |
14 minutes |
–23 °C |
+12.9 °C |
> 60 minutes |
|
-30 °C |
+20 °C |
-14.2 °C |
18 minutes |
+6 °C |
-18.2 °C |
15.5 minutes |
Failure test - Configuration as in GDP-TK-OQ-SP-MT figure 8, Single Zone Control and wall stowed
Ambient | Setpoint | Time to move out of the range | Rules to apply |
+40 °C |
+5 °C |
8.5 minutes |
Above +8 °C or max 2hrs. |
–23 °C |
8.5 minutes |
Above -20 °C or max 2hrs. |
|
-30 °C |
+20 °C |
33.5 minutes |
Below +15 °C or max 2hrs. |
+5 °C |
7 minutes |
Below +2 °C or max 2hrs. |