Detailed Specifications

Diving Wall ATP Specification

Diving wall ATP Specification

  K factor coefficient Minimum thickness of diving wall
  Removable Fixed
GRP floor Longitudinal

2.0 W/m2.K

1.5 W/m2.K

25 mm
GRP floor Transversal

2.6 W/m2.K

1.5 W/m2.K

40 mm
Aluminium floor Longitudinal

3.0 W/m2.K

2.0 W/m2.K

25 mm
Aluminium floor Transversal

3.2 W/m2.K

2.0 W/m2.K

40 mm

Diving wall coefficients include a safety margin to allow for degradation and thermal leakages.

Refrigerated Unit capacity:

  Refrigeration capacities 1    
Refrigerant R-404A/R-452A    
       
Unit Model   T-1200R Spectrum S3+S3  
    Total Nominal Remote Evaporator S3
Capacity on engine power  0 °C  12 080 W 8 120 W
-20 °C 7 620 W 4 640 W
Capacity on electric standby  0 °C  7 560 W 7 163 W
-20 °C  4 720 W 4 010 W
       
Unit Model   T-1000R Spectrum S3+S3  
    Total Nominal Remote Evaporator S3
Capacity on engine power  0 °C  9 990 W 7 540 W
-20 °C 5 790 W 4 230 W
Capacity on electric standby  0 °C  6 280 W 6 190 W
-20 °C  3 860 W 3 490 W
       
Unit Model   T-1200R Spectrum S3+S3  
    Total Nominal Remote Evaporator S3
Capacity on engine power  0 °C  10 560 W 7 720 W
-20 °C 6 030 W 4 410 W
Capacity on electric standby  0 °C  7 560 W 6 840 W
-20 °C  4 720 W 3 820 W
Airflow volume at 0 Pa static pressure    

2 000 m3/hr

Discharge velocity (Air throw)     9.50 m/sec
 
Refrigerant R-452A
Unit Model UT-R Spectrum S3+S3
    Total Nominal Remote Evaporator S3
Capacity on engine power  0 °C  11 302 W 7 780W
-20 °C 6 374 W 4 463 W

Capacity on electric standby

 0 °C  10 249W 6 861 W
-20 °C 4 497 W 3 652 W
Airflow volume at 0 Pa static pressure    

2 350 m3/hr

Discharge velocity (Air throw)

   

9.50 m/sec

       
Maximum zone length (2)     5.50 m
       

1 At +30°C ambient temperature under ATP conditions

2 Maximum recommended dimensions: these are guidelines based on airflow and air velocity requirements based upon the following assumptions: K factor = 0.4W/m2.K, internal height up to 2.5 m, width up to 2.5 m, zero heat load from produce carried. For each application, a heat load calculation must be performed (applies to all listed unit models).