Identified Risks and Preventative Actions
Closed Box
Process | Defining the Possible Process Problem | Likelihood | Consequence | Risk | Preventative Action |
---|---|---|---|---|---|
Poor design of the transport equipment | Equipment not equivalent to sample-type equipment fully GDP qualified Poor quality finishes (example: bad insulation) | 2 | 4 | 8 (Moderate) |
|
The refrigerated unit has been installed incorrectly on the body | Installation Qualification to be conducted and checked by Thermo King authorized and trained technician. | ||||
Temperature excursions | Unexplained temperature excursions | 3 | 4 | 12 (Moderate) | Datalogger and/or a monitoring system should be installed on the transport equipment. |
Installations obstructing the discharge air flow | Correctly check design specifications of the equipment at point of sales. | ||||
Transport equipment not pre-cooled before loading goods | Pre-cool the transport equipment to the set -temperature before loading the products. | ||||
Products not loaded at correct temperature. | Implement correct loading/unloading practices. | ||||
Inadequate split of the compartments of the transport equipment. | When operating the equipment in multi-temperatures mode, the splitting of the compartment zones should be up to 1/2 of the total body length. | ||||
Settings of the refrigerated unit | Incorrect settings of set points for the temperature range to be maintained | 3 | 4 | 12 (Moderate) | To
maintain the best temperature management within the load-space in
winter and summer time, Thermo King recommends operating with the
following set point temperatures:
|
Incorrect settings of the refrigerated unit then the vehicle is being used in multi-temperatures mode. | At IQ, a specific configuration file is loaded to the controller. When operating the equipment in multi-temperatures mode, ZONE PRIORITY function must be DISABLED. | ||||
Incorrect settings of the refrigerated unit when the vehicle is being used in single temperature mode. | At IQ, a specific configuration file is loaded to the controller. In case of single-temperature operation the unit must run in SINGLE ZONE CONTROL (SZC) mode and the dividing wall must be stowed in such a way that it does not interrupt the airflow from each remote evaporator. For ease of use, SZC mode should be added to the Main (driver) menu. |
Environment
Process | Defining the Possible Process Problem | Likelihood | Consequence | Risk | Preventative Action |
---|---|---|---|---|---|
Temperature Europe |
Expected ambient temperature in the regions can go up to extremes. | 3 | 3 | 9 (Moderate) |
Full Qualification of sample-type equipment (temperature mapping) has been successfully performed at extreme temperatures from -30°C to +40°C. |
Risk of temperature excursion due to high delta difference with inside temperature. |
Refrigeration capacity reserve: Thermo King equipment are designed as standard to overcome temperature met in Middle East Africa regions, with temperatures up to 55°C. |
||||
Solar radiation | In summertime, the effect of solar radiation can have a negative impact on the surface temperature of the equipment. The darker the body colour, the higher temperature increase. | 2 | 3 | 6 (Moderate) | In
DQ, recommended body to be white in colour with a max. 20% decal coverage. Refrigeration capacity reserve: Thermo King equipment are designed as standard with reserve capacity of 75% based on ATP standards. |
Door opening at non-temperature-controlled storage location | Depending on:
|
3 | 4 | 12 (Moderate) | Minimize door opening
time. Load and unload the transport equipment at temperature-controlled loading docks of storage location. Driver training on best loading/unloading practices should be conducted. Door opening tests have been performed to enable better risk management. |
Process / Operational Qualification
Process | Defining the Possible Process Problem | Likelihood | Consequence | Risk | Preventative Action |
---|---|---|---|---|---|
Temperature sensor accuracy check |
Invalid temperature registration | 2 | 4 | 8 (Moderate) | At
IQ check Process, all sensors that are used for temperature control
and monitoring are to be checked. A proof of calibration checks of
each sensor as part of IQ Process. Yearly calibration check of all sensors that are used for temperature control and monitoring. Minimum sensor requirements and location should be in accordance with equipment manufacturer's recommendations. The calibration process should be in line with the EN13486. |
Breakdown / Damage of the equipment | No
regular maintenance of the transport equipment Maintenance not done correctly No use of genuine parts |
2 | 4 | 8 (Moderate) | A
maintenance contract with Thermo King or authorized Thermo King dealer
should be in place. If no maintenance contract, the user of the equipment should prove that he has the right schedule maintenance, repair procedures, genuine parts, breakdown risk assessment, and training in place.The user should be open to regular audits. All replacement parts are to be from genuine manufacturer's parts. |
Lack of hygiene | Risk of contamination of pharmaceutical products | 3 | 3 | 9 (Moderate) | A
Cleaning Procedure should be in place. The internal space is easily accessible for cleaning. The internal surfaces of the refrigeration body are corrosion-resistant and comply with hygiene regulations. Pharmaceutical products should not be transported in a mixed load with food products. |
Incorrect operating mode |
Transport
equipment not used appropriately. Lack of knowledge on how to use the refrigerated unit |
3 | 4 | 12 (Moderate) | Thermo
King provides an Operational manual to use efficiently the transport
equipment. Conduct Training of drivers on GDP and how to use the refrigerated unit. |
Transport equipment used with Frozen -Fresh/Ambient or Ambient/Fresh - Frozen Setpoint during Multi-Temp operation. | 3 | 4 | 12 (Moderate) | During multi-temperature use, it is strictly not permitted if one zone is set for Frozen, the other zone cannot be used for chilled / ambient operation. |