Thermocouple Locations

There is no information in GDP guideline as to location of or how many thermo couplings for temperature measurement should be inserted into the load space during the qualification test. Therefore, the locations of the thermo couplings are referred to as in the ATP guideline. ATP is using standard NFX 15-140. This means 15 thermocouples per zone are utilised in the box during the multi-temperature’s qualification test and 25 thermocouples for the single temperature qualification test. These loggers are calibrated, and the calibration documents are available under request.

T-1200R S3+S3, T-1000R S3+S3, UT-1200 S3+S3 and UT-R Spectrum S3+S3 thermocouple locations multi-temperatures operation Z1 length = 1/2 / Z2 length = 1/2 of total length

  • EAIT_1 Return air sensor Zone 1

  • EAOT_1 Supply air sensor Zone 1

  • EAIT_2 Return air sensor Zone 2

  • EAOT_2 Supply air sensor Zone 2

  • Thermocouples Ti1_01, Ti1_06, Ti1_11, Ti2_01, Ti2_06 and Ti2_11 are located at Top right corner 150 mm away from any wall/door.

  • Thermocouples Ti1_02, Ti1_07, Ti1_12, Ti2_02, Ti2_07 and Ti2_12 are located at Right bottom corner between boxes and wall.

  • Thermocouples Ti1_03, Ti1_08, Ti1_13, Ti2_03, Ti2_08 and Ti2_13 are located at Left bottom corner between boxes and wall.

  • Thermocouples Ti1_04, Ti1_09, Ti1_14, Ti2_04, Ti2_09 and Ti2_14 are located at Top left corner 150 mm away from any wall/door.

  • Thermocouples Ti1_05, Ti1_10, Ti1_15, Ti2_05, Ti2_10 and Ti2_15 are located in the centre.

T-1200R S3+S3, T-1000R S3+S3, UT-1200 S3+S3 and UT-R Spectrum S3+S3 thermocouple locations, single temperature operation

  • EAIT_1 Return air sensor

  • EAOT_1 Supply air sensor

  • EAIT_2 Return air sensor (SZC)

  • EAOT_2 Supply air sensor (SZC)

  • Thermocouples Ti1_01, Ti1_06, Ti1_11, Ti1_16 are located at Top right .

  • Thermocouples Ti1_02, Ti1_07, Ti1_12, Ti1_17 are located at Right bottom corner 150 mm from any wall.

  • Thermocouples Ti1_03, Ti1_08, Ti1_13, Ti1_18 are located at Left bottom corner between boxes and wall.

  • Thermocouples Ti1_04, Ti1_09, Ti1_14, Ti1_19 are located at Top left corner between boxes and wall.

  • Thermocouples Ti1_05, Ti1_10, Ti1_15, Ti1_20 are located in the centre.