Evaluation of the Qualification Test

Test Results – Truck T-800R

Test Ambient Setpoint Min/Max Sensor Temperature Min/Max Average Temperature Average Temperature Deviation

1

+40°C

+ 20°C

+18°C / +22°C

+20°C

-1/+1°C of set point

2

+40°C

+ 5°C

+2°C / +8°C

+6 °C

+2°C of set point

3

+40°C

–25°C

-23°C / -21°C

-22 °C

+3°C of set point

4

-30°C

+ 20°C

+16°C / +20°C

+20°C

-3/0°C of set point

5

-30°C

+ 5°C

+2°C / +5°C

+3 °C

-2/0°C of set point

6

-30°C

–25°C

-30°C / -26°C

-26°C

0/-3°C of set point

Test Results – Truck T-1000R

Test Ambient Setpoint Min/Max Sensor Temperature Min/Max Average Temperature Average Temperature Deviation

1

+45°C

+ 20°C

19 / 23

19 / 22

+2/-1°C of set point

2

+45°C

+ 5°C

4 / 8

5 / 7

+2°C of set point

3

+40°C

–25°C

-26 / -20

-24 / -21

+4°C of set point

4

-30°C

+ 20°C

17 / 19

18 / 19

-2°C of set point

5

-30°C

+ 5°C

3 / 6

3 / 6

+1/-2°C of set point

6

-30°C

–25°C

-29 / -25

-29 / -25

-4°C of set point

Test Results – Container with T-1200R Intermodal

Test Ambient Setpoint Min/Max Sensor Temperature Min/Max Average Temperature Average Temperature Deviation

1

+40°C

+ 20°C

18 / 23

20 / 22

+2°C of set point

2

+40°C

+ 5°C

4 / 8

5 / 7

+2°C of set point

3

+40°C

–25°C

-29/ -22

-28 / -23

+/-2°C of set point

4

-30°C

+ 20°C

18 / 20

18 / 19

-2°C of set point

5

-30°C

+ 5°C

3 / 7

4 / 6

+/-1°C of set point

6

-30°C

–25°C

-24 / -19

-24 / -20

-4°C of set point

Test Results - Truck UT-1200

Test Ambient Setpoint Min/Max Sensor Temperature Min/Max Average Temperature Average Temperature Deviation

1

+45°C

+ 20°C

18 / 22

19 / 21

+/-1°C of set point

2

+45°C

+ 5°C

3 / 8

4 / 7

+2/-1°C of set point

3

+40°C

–25°C

-27 / -21

-26 / -23

+2/-1°C of set point

4

-30°C

+ 20°C

15 / 22

18 / 21

+1/-2°C of set point

5

-30°C

+ 5°C

3 / 7

3 / 6

+1/-2°C of set point

6

-30°C

–25°C

-29 / -24

-28 / -25

-3°C of set point