Detailed Specifications
Air chute
Air chute system is required only for the T-1200R Intermodal on a 45 feet container.
It should conform to Thermo King recommended minimum standards in the ceiling of the trailer and to provide the same or better air distribution as the Thermo King Air Chute.
-
The guiding plenum opening should be a minimum square area equal to 1.5 times the square area of the evaporator outlet.
-
The outlet of the chute should also have a minimum square area equal to 1.5 times the square area of the evaporator outlet.
-
Thermo King air chute gives the best optimization of air and temperature so that a uniform temperature is formed throughout the container.
Refrigerated Unit capacity
Unit capacity T-800R , T-1000R, T-1200R and UT-1200
At setpoint | T-800R | T-1000R | T-1200R T-1200R Intermodal |
UT-1200 S-3 + S-3 |
|
Refrigeration Capacity | |||||
Refrigerant | R-404A / R-452A | ||||
Capacity in engine power1 | 0°C | 8000W | 9600 W | 12500 W | 11200 W |
-20°C | 4200W | 5300 W | 6800 W | 6600 W | |
Capacity on electric standby1 | 0°C | 6000W | 6700 W | 9250 W | 8900 W |
-20°C | 3200W | 4100 W | 5200 W | 5100 W | |
Heating capacity engine power | -18°C | 3100W | 4100 W | 7800 W | 6100 W |
Airflow | 2700 m3/hr | 3200 m3/hr | 3300 m3/hr | 4700 m3/hr | |
Air throw | 5.2 m/sec | 6.2 m/sec | 6.4 m/sec | 9.5 m/sec | |
1at +30°C ambient temperature |