Failure tests were conducted at the ambient temperatures +40°C
and -30°C. The below table provides failure tests results:
Failure test - Truck T-800R
Ambient |
Setpoint |
Time to
move out of the range |
Rules to
apply |
+40°C |
+20°C |
90 minutes |
Above +25°C
or maximum 2 hours |
+5°C |
10 minutes |
Above +8°C
or maximum 2 hours |
-25°C |
16 minutes |
Above -20°C
or maximum 2 hours |
|
-30°C |
+20°C |
28 minutes |
Below +15°C
or maximum 2 hours |
+5°C |
20 minutes |
Below +2°C
or maximum 2 hours |
Failure test - Truck T-1000R
Ambient |
Setpoint |
Time to move out of the range |
Rules to apply |
+15°C |
-25°C |
20
minutes |
Below
-20°C or maximum 2 hours |
|
-30°C |
+20°C |
14 minutes |
Above +15°C or maximum
2 hours |
Failure test – Truck UT-1200
Ambient |
Setpoint |
Time to move out of the range |
Rules to apply |
+40°C |
+20°C |
38
minutes |
Above
+25°C or maximum 2 hours |
+5°C |
11
minutes |
Above
+8°C or maximum 2 hours |
-25°C |
5 minutes |
Above
-20°C or maximum 2 hours |
|
-30°C |
+20°C |
15
minutes |
Below
+15°C or maximum 2 hours |
+5°C |
1 minutes |
Below
+2°C or maximum 2 hours |