Test Results – Failure Tests

Failure tests were conducted at the ambient temperatures +40°C and -30°C. The below table provides failure tests results:

Failure test - Truck T-800R

Ambient  Setpoint  Time to move out of the range  Rules to apply 
+40°C +20°C 90 minutes Above +25°C or maximum 2 hours 
+5°C 10 minutes Above +8°C or maximum 2 hours 
-25°C 16 minutes Above -20°C or maximum 2 hours 
 
-30°C +20°C 28 minutes Below +15°C or maximum 2 hours 
+5°C 20 minutes Below +2°C or maximum 2 hours 

Failure test - Truck T-1000R

Ambient  Setpoint  Time to move out of the range  Rules to apply 
+15°C -25°C 20 minutes Below -20°C or maximum 2 hours
 
-30°C +20°C 14 minutes Above +15°C or maximum 2 hours

Failure test – Truck  UT-1200

Ambient  Setpoint  Time to move out of the range  Rules to apply 
+40°C +20°C 38 minutes Above +25°C or maximum 2 hours
+5°C 11 minutes Above +8°C or maximum 2 hours
-25°C 5 minutes Above -20°C or maximum 2 hours
 
-30°C +20°C 15 minutes Below +15°C or maximum 2 hours
+5°C 1 minutes Below +2°C or maximum 2 hours