Refrigeration System

Compressor   ZMD27KVE-TFD, Scroll
Refrigerant Charge   5.2 Kg (11.4 lb.) R-134a
Compressor Oil Capacity
Note When the compressor is removed from the unit, oil level should be noted or the oil removed from the compressor should be measured so that the same amount of oil can be maintained in the replacement compressor.
1.77 liter (60 oz.)
Compressor Oil Type
Note Do not use or add standard synthetic or mineral oils to the refrigeration system. If Ester based oil becomes contaminated with moisture or with standard oils, dispose of properly - DO NOT USE.
Polyol Ester Based Type (required), (refer to Tool Catalog)
High Pressure Cutout Switch

Cutout

Cutin

2302 ± 100 kPa, 23 ± 1 bar, 334± 15 psig

1703 ± 144kPa, 17.9 ± 1.5 bar, 247± 21 psig

Low Pressure Cutout Switch

Cutout


Cutin

-33 to -54 kPa, -0.34 to -0.54 bar, 10 to 16 in. Hg vacuum

11.8 to 28 kPa, 0.12 to 0.28 bar, 3.5 to 8.5 psig

High Pressure Relief Valve Relief Temperature 80 °C, 176 °F
Vapor Injection Control Modulation Cool or Power Limit Vapor injection shall turn on if top cap thermistor reads 138°C±1°C (280°F±2°F)
Compressor Discharge Temperature Control

Vapor Injection Valve Energizes (Opens)

138°C (280 °F)

R-134a Refrigerant - Maximum Cool Operation

Container Temperature Ambient Temperature Suction Pressure Discharge Pressure**

70°F

(21°C)

80°-100°F

(27°-38°C)

16-20 psig

110-140 kPa

1.10-1.40 bar

220-240 psig

1520-1660 kPa

15.20-16.60 bar

35°F

(2°C)

80°-100°F

(27°-38°C)

7-11 psig

50-75 kPa

0.50-0.75 bar

180-200 psig

1240-1380 kPa

12.40-13.80 bar

0°F

(-18°C)

80°-100°F

(27°-38°C)

9”-5”

-30 to -17 kPa

-0.30 to -0.17 bar

160-175 psig

1100-1210 kPa

11.00-12.10 bar

-20°F

(-29°C)

80°-100°F

(27°-38°C)

14”-11” psig

-47 to -37 kPa

-0.47 to -0.37 bar

150-170 psig

1035-1175 kPa

10.35-11.75 bar

Suction and discharge pressures vary too greatly during Modulation Cool to use for evaluating or diagnosing refrigeration system performance. During the Modulation Cool mode, the suction pressure will vary between 100 and 450 kPa, 1.0 and 4.5 bar, 15 and 65 psig depending upon the percent (percent) cooling capacity.

**Discharge pressure is determined by condenser fan cycling.