Advanced Fresh Air Management Plus (AFAM+) System

The Advanced Fresh Air Management Plus (AFAM+) System provides programmable control of the CO2 level in the container. The controller can be set to control the CO2 level in the container from 0 to 25 percent. Refer to (Advanced Fresh Air Management Plus (AFAM+) System) for more information.

Unit Front View      
     
     
  1 Evaporator Access Door
  2 Condenser Fan
  3 Compressor Compartment
  4 Scroll Compressor
  5 Control Box
  6 Rear Download and USDA Receptacle Panel (Access from Inside Container)
     

Unit Rear View      
     
     
  1 Evaporator Grille
  2 Air Channels
  3 Fresh Air Inlet
  4 Top Rear Plate
  5 Bottom Rear Plate
  6 USDA Receptacle Panel: Controller Communications and Data Download Port, USDA1/Spare 1 Sensor Connection, USDA2/Spare 2 Sensor Connection, USDA3/Spare 3 Sensor Connection, Cargo (Pulp) Sensor Connection
     

Refrigeration System

1 Expansion Valve 5 Receiver Tank 9 Low Pressure Cutout Switch
2 Evaporator Coil 6 Scroll Compressor 10 Economizer Heat Exchanger
3 Expansion Valve (Economizer) 7 Ball Valve 11 Vapor Injection Solenoid Valve
4 Condenser Coil 8 Digital Control Valve 12 Dehydrator

Electrical Components

1 Sensor Kit 8 Heater Group 15 Humidity Sensor 22 Cable Connection
2 Evaporator Fans Harness 9 Condenser Fan Motor 16 Vapor Injection Valve 23 Cable Supply
3 Power Cable Bracket 10 Condenser Fan Harness 17 Compressor Sensor 24 Kit CO2/O2 RS485 sensor
4 Power Cable 11 Evaporator Fan Motor 18 Digital Valve 25 Humidity Sensor (for OOCL)
5 Power Plug 12 USDA Receptacle Panel 19 Control Box 26 Temperature Sensor
6 Scroll Compressor 13 Suction Transducer 20 Compressor Cable 27 CO2 Sensor
7 HPCO Switch 14 Pocket Sensor 21 Liquid Tite Connector