Set AFAM+ System Values
The Controlled Atmosphere (CA) option submenu in the Config menu is factory set to AFAM+. The controller then adds the AFAM, AFAM Delay, AFAM Rate, and CO2 Max submenus to the Controls menu. If a replacement controller or new software is installed, a controller auto configuration will detect the AFAM+ option when the AFAM door control module and gas sensor are connected to the controller.
-
AFAM+: This setting turns on the AFAM+ system to control the CO2 gas level. The controller then adds CO2 Max and AFAM Delay submenus to the Controls menu.
The default setting for AFAM in the Controls menu is the last value set (Off, AFAM, or AFAM+). Controlled Atmosphere (CA) and Fresh Air Vent Man must be set to AFAM+ to control the vent door to the CO2 gas level.
-
Press the F4 key to enter the main menu. Press the F2 or F3 key to scroll to Config menu and press F4 to expand the menu. 2. 3.
-
Press the F2 or F3 key to scroll to Options menu and press F4 to expand the menu.
-
Press the F2 or F3 key to scroll to Controlled Atmosphere (CA) menu and press F4 to enter the menu.
-
Press the F2 or F3 key to select AFAM+ and press and hold F4 to accept the selection.
-
Press the F1 key several times to return to the standard display.
-
Press the F4 key to enter the main menu. Press the F2 or F3 key to scroll to Controls menu and press F4 to expand the menu.
-
Press the F2 or F3 key to scroll to Fresh Air Vent Man.
-
Press the F4 key to enter the Fresh Air Vent Man menu.
-
Press the F2 or F3 key to scroll between [OFF], [AFAM], and [AFAM+].
-
[OFF]: Vent door closes and/or remains closed. AFAM Delay and CO2 Max settings disappear.
-
[AFAM]: Controller uses enter AFAM DELAY and AFAM RATE time to adjust FAE door to user setting.
-
[AFAM]: Controller uses enter AFAM DELAY and CO2 Max to adjust FAE door to user setting.
-
-
Press and hold the F4 key with the desired state in the menu line until you are returned to the Controls menu.
-
Press the F1 key several times to return to the standard display.