Main Module Alarms – Default

Note Some of the alarm codes listed are reserved for special applications only.

Alarm prefix for module identification of articulated or special application systems

MM ID MM position Final indicated Alarm number value
ID00 Front or Single unit Alarm No = value from column A
ID01 Rear or Middle unit Alarm No = value from column A + 100
ID02 Rear unit or special app Alarm No = value from column A + 200

Example:
Alarm 001: Clutch on MM0
Alarm 101: Clutch on MM1
Alarm 201: Clutch on MM2

Alarm No Severity Description
1 R Clutch 1 output open circuit
2 R Clutch 1 output short circuit or overcurrent
3 Y Low pressure cut-out compressor 1
4 R High pressure cut-out compressor 1
5 R Low pressure cut-out compressor1 cycled 13 times in 10 min.
6 R Low pressure cut-out compressor 1 longer than 10 min.
7 Y Return air temperature sensor failure - low value
8 Y Return air temperature sensor failure - high value
9 Y Evaporator coil temperature sensor CTS1 failure - low value
10 Y Evaporator coil temperature sensor CTS1 failure - high value
11 Y Ambient temperature Sensor failure - low value
12 Y Ambient temperature Sensor failure - high value
13 Y Temperature Sensor CTS2 failure - low value.
14 Y Temperature Sensor CTS2 failure - high value
15 Y Duct air temperature sensor failure (DTS1) - low value
16 Y Duct air temperature sensor failure (DTS1) - high value
17 Y Temperature sensor failure (DTS2) - low value
18 Y Temperature sensor failure (DTS2) - high value
19 Y Screw Compressor discharge temp. sensor failure - low value
20 R Screw Compressor discharge temp. sensor failure -high value
21 R Clutch 2 output open circuit
22 R Clutch 2 output short circuit or overcurrent
23 Y Low pressure cut-out compressor 2
24 R High pressure cut-out compressor 2
25 R Low pressure cut-out compressor 2 cycled 13 times in 10 min.
26 R Low pressure cut-out compressor 2 longer than 10 min.
27 R Clutch 1 cycling
28 R Clutch 2 cycling
29 O Evaporator coil 1 frozen
30 O Evaporator coil 2 frozen
31 Y Compressor discharge temperature warning
32 R Compressor discharge temperature shutdown
33 Y Fresh air servo 1 failed during initialization
34 Y Fresh air servo 1 failure
35 Y Fresh air servo 2 failed during initialization
36 Y Fresh air servo 2 failure
37 Y Heater valve servo 1 failed during initialization
38 Y Heater valve servo 1 failure
39 Y Heater valve servo 2 failed during initialization
40 Y Heater valve servo 2 failure
41 Y SM1 output failure
42 Y SM2 output failure
43 Y SM3 output failure
44 Y SM4 output failure
45 Y SM5 output failure
46 Y SM6 output failure
47 Y EEPROM error
48 Y Configuration check sum error
49 Y Heater valve servo 3 failed during initialization
50 Y Evaporator fan low speed output open circuit or underload
51 Y Evaporator fan low speed output short circuit or overload
52 Y Evaporator fan med.speed output open circuit or underload
53 Y Evaporator fan med. speed output short circuit or overload
54 Y Evaporator fan high speed output open circuit or underload
55 Y Evaporator fan high speed output short circuit or overload
56 Y Condenser fan low speed output open circuit or underload
57 Y Condenser fan low speed output short circuit or overload
58 Y Condenser fan high speed output open circuit or underload
59 Y Condenser fan high speed output short circuit or overload
60 Y LSB (liquid solenoid Bottom)output open circuit or underload
61 Y LSB (liquid solenoid Bottom) output short circuit or overload
62 Y LST (liquid solenoid Top) output open circuit or underload
63 Y LST (liquid solenoid Top) output short circuit or overload
64 Y Boost pump relay output open circuit or underload
65 Y Boost pump relay output short circuit or overload
66 Y OTP1 output open circuit or underload
67 Y OTP1 short circuit or underload
68 Y OTP2 output open circuit or underload
69 Y OTP2 short circuit or underload
70 Y Missing CAN message from FH second zone / second deck / Stroco preheater
71 Y Evaporator blower fault
72 Y Condenser fan fault
73 R Discharge pressure transducer 1 out of range - low
74 R Discharge pressure transducer 1 out of range - high
75 R Discharge pressure transducer 2 out of range - low
76 R Discharge pressure transducer 2 out of range - high
77 Y Suction pressure transducer 1 out of range - low
78 Y Suction pressure transducer 1 out of range - high
79 Y Suction pressure transducer 2 out of range - low
80 Y Suction pressure transducer 2 out of range - high
81 Y Preheater Valeo/Webasto: F01 – no start after two attempts
Preheater Eberspaecher: 50/52 – Safety time exceed
Preheater Stroco: 1 – Safety time exceed
82 Y Preheater Valeo/Webasto: F02 – flame out (at least 5-times)
Preheater  Eberspaecher: 54 – Flame cutout
Preheater Stroco: N/A (not defined)
83 Y Preheater  Valeo/Webasto: F03 – low voltage or excess voltage
Preheater Eberspaecher: 11 – Undervoltage cut-off
Preheater Stroco: 4 – Undervoltage
84 Y Preheater Valeo/Webasto: F04 – foreign light detected
Preheater Eberspaecher: 16/51/58 – Flame monitor
Preheater Stroco: N/A (not defined)
85 Y Preheater Valeo/Webasto: F05 – flame sensor defective
Preheater Eberspaecher: Connection Error (many internal alarms)
Preheater Stroco: 3 – Photodetector defective
86 Y Preheater Valeo/Webasto: F06 – temperature sensor defective
Preheater Eberspaecher: 14/60/61/71/72 – Temperature sensor
Preheater Stroco: 8 – Sensor defective
87 Y Preheater Valeo/Webasto: F07 – Solenoid Valve defective
Preheater Eberspaecher: 10 – Overvoltage cut-off
Preheater Stroco: 7 – Solenoid Valve defective
88 Y Preheater Valeo/Webasto: F08 – Fan Motor Defective
Preheater Eberspaecher: 32/33 – Burner Motor
Preheater Stroco: 6 – Fan defective
89 Y Preheater Valeo/Webasto: F09 – Circulation Pump Defective
Preheater Eberspaecher: N/A (not defined)
Preheater Stroco: N/A (not defined)
90 Y Preheater Valeo/Webasto: F10 – Temperature Limiter Defective
Preheater Eberspaecher: 12/15 – Overheating
Preheater Stroco: 10 – Overtemperature alarm
91 Y Preheater Valeo/Webasto: F11 – Igniter Box Defective
Preheater Eberspaecher: Diagnostic Output Failure
Preheater Stroco: 2 – Ignition Electrode Defective
92 Y Preheater Valeo/Webasto: F12 – Error lockout, repeated malfunction / repeated flame out
Preheater Eberspaecher: 90-97 – Control Box
Preheater Stroco: 9 – Too many start attempts
93 Y Missing voltage for main module power 24 V-3
94 Y Missing CAN message from second unit (articulated systems)
95 Y Missing CAN message from FH first zone/first deck
96 Y Missing CAN message from DP
97 R Hydraulic Pressure High Value
98 Y Clutch 1 fuse failure
99 Y Clutch 2 fuse failure
100 Y Vehicle CAN1 message(s) missing / not valid
     
701 Y Preheater Valeo/Webasto: F13 – Electrical Pressure Regulator defective (CNG only)
Preheater Eberspaecher: N/A (not defined)
Preheater Stroco: 5 – Overvoltage
     
703 Y Expansion water tank LOW (HV vehicle battery water circuit)
704 Y Expansion water tank CRITICAL (HV vehicle battery water circuit)
705 Y Expansion water tank HW error (HV vehicle battery water circuit)
706 Y Electrostatic filter clogged
707 Y Electrostatic filter faulty
     
709 Y High voltage relay 1 damaged (HV DC electric preheater section 1)
710 Y High voltage relay 2 damaged (HV DC electric preheater section 2)
711 Y High voltage relay 3 damaged (HV DC electric preheater section 3)
712 Y High voltage relay 4 damaged (HV DC electric preheater section 4)