Main Module Alarms – Default
Note Some of the alarm codes listed are reserved for
special applications only.
Alarm prefix for module identification of articulated or special application systems
MM ID | MM position | Final indicated Alarm number value |
---|---|---|
ID00 | Front or Single unit | Alarm No = value from column A |
ID01 | Rear or Middle unit | Alarm No = value from column A + 100 |
ID02 | Rear unit or special app | Alarm No = value from column A + 200 |
Example:
Alarm 001: Clutch on MM0
Alarm 101: Clutch on MM1
Alarm 201: Clutch on MM2
Alarm No | Severity | Description |
---|---|---|
1 | R | Clutch 1 output open circuit |
2 | R | Clutch 1 output short circuit or overcurrent |
3 | Y | Low pressure cut-out compressor 1 |
4 | R | High pressure cut-out compressor 1 |
5 | R | Low pressure cut-out compressor1 cycled 13 times in 10 min. |
6 | R | Low pressure cut-out compressor 1 longer than 10 min. |
7 | Y | Return air temperature sensor failure - low value |
8 | Y | Return air temperature sensor failure - high value |
9 | Y | Evaporator coil temperature sensor CTS1 failure - low value |
10 | Y | Evaporator coil temperature sensor CTS1 failure - high value |
11 | Y | Ambient temperature Sensor failure - low value |
12 | Y | Ambient temperature Sensor failure - high value |
13 | Y | Temperature Sensor CTS2 failure - low value. |
14 | Y | Temperature Sensor CTS2 failure - high value |
15 | Y | Duct air temperature sensor failure (DTS1) - low value |
16 | Y | Duct air temperature sensor failure (DTS1) - high value |
17 | Y | Temperature sensor failure (DTS2) - low value |
18 | Y | Temperature sensor failure (DTS2) - high value |
19 | Y | Screw Compressor discharge temp. sensor failure - low value |
20 | R | Screw Compressor discharge temp. sensor failure -high value |
21 | R | Clutch 2 output open circuit |
22 | R | Clutch 2 output short circuit or overcurrent |
23 | Y | Low pressure cut-out compressor 2 |
24 | R | High pressure cut-out compressor 2 |
25 | R | Low pressure cut-out compressor 2 cycled 13 times in 10 min. |
26 | R | Low pressure cut-out compressor 2 longer than 10 min. |
27 | R | Clutch 1 cycling |
28 | R | Clutch 2 cycling |
29 | O | Evaporator coil 1 frozen |
30 | O | Evaporator coil 2 frozen |
31 | Y | Compressor discharge temperature warning |
32 | R | Compressor discharge temperature shutdown |
33 | Y | Fresh air servo 1 failed during initialization |
34 | Y | Fresh air servo 1 failure |
35 | Y | Fresh air servo 2 failed during initialization |
36 | Y | Fresh air servo 2 failure |
37 | Y | Heater valve servo 1 failed during initialization |
38 | Y | Heater valve servo 1 failure |
39 | Y | Heater valve servo 2 failed during initialization |
40 | Y | Heater valve servo 2 failure |
41 | Y | SM1 output failure |
42 | Y | SM2 output failure |
43 | Y | SM3 output failure |
44 | Y | SM4 output failure |
45 | Y | SM5 output failure |
46 | Y | SM6 output failure |
47 | Y | EEPROM error |
48 | Y | Configuration check sum error |
49 | Y | Heater valve servo 3 failed during initialization |
50 | Y | Evaporator fan low speed output open circuit or underload |
51 | Y | Evaporator fan low speed output short circuit or overload |
52 | Y | Evaporator fan med.speed output open circuit or underload |
53 | Y | Evaporator fan med. speed output short circuit or overload |
54 | Y | Evaporator fan high speed output open circuit or underload |
55 | Y | Evaporator fan high speed output short circuit or overload |
56 | Y | Condenser fan low speed output open circuit or underload |
57 | Y | Condenser fan low speed output short circuit or overload |
58 | Y | Condenser fan high speed output open circuit or underload |
59 | Y | Condenser fan high speed output short circuit or overload |
60 | Y | LSB (liquid solenoid Bottom)output open circuit or underload |
61 | Y | LSB (liquid solenoid Bottom) output short circuit or overload |
62 | Y | LST (liquid solenoid Top) output open circuit or underload |
63 | Y | LST (liquid solenoid Top) output short circuit or overload |
64 | Y | Boost pump relay output open circuit or underload |
65 | Y | Boost pump relay output short circuit or overload |
66 | Y | OTP1 output open circuit or underload |
67 | Y | OTP1 short circuit or underload |
68 | Y | OTP2 output open circuit or underload |
69 | Y | OTP2 short circuit or underload |
70 | Y | Missing CAN message from FH second zone / second deck / Stroco preheater |
71 | Y | Evaporator blower fault |
72 | Y | Condenser fan fault |
73 | R | Discharge pressure transducer 1 out of range - low |
74 | R | Discharge pressure transducer 1 out of range - high |
75 | R | Discharge pressure transducer 2 out of range - low |
76 | R | Discharge pressure transducer 2 out of range - high |
77 | Y | Suction pressure transducer 1 out of range - low |
78 | Y | Suction pressure transducer 1 out of range - high |
79 | Y | Suction pressure transducer 2 out of range - low |
80 | Y | Suction pressure transducer 2 out of range - high |
81 | Y | Preheater Valeo/Webasto: F01 – no start after two attempts |
Preheater Eberspaecher: 50/52 – Safety time exceed | ||
Preheater Stroco: 1 – Safety time exceed | ||
82 | Y | Preheater Valeo/Webasto: F02 – flame out (at least 5-times) |
Preheater Eberspaecher: 54 – Flame cutout | ||
Preheater Stroco: N/A (not defined) | ||
83 | Y | Preheater Valeo/Webasto: F03 – low voltage or excess voltage |
Preheater Eberspaecher: 11 – Undervoltage cut-off | ||
Preheater Stroco: 4 – Undervoltage | ||
84 | Y | Preheater Valeo/Webasto: F04 – foreign light detected |
Preheater Eberspaecher: 16/51/58 – Flame monitor | ||
Preheater Stroco: N/A (not defined) | ||
85 | Y | Preheater Valeo/Webasto: F05 – flame sensor defective |
Preheater Eberspaecher: Connection Error (many internal alarms) | ||
Preheater Stroco: 3 – Photodetector defective | ||
86 | Y | Preheater Valeo/Webasto: F06 – temperature sensor defective |
Preheater Eberspaecher: 14/60/61/71/72 – Temperature sensor | ||
Preheater Stroco: 8 – Sensor defective | ||
87 | Y | Preheater Valeo/Webasto: F07 – Solenoid Valve defective |
Preheater Eberspaecher: 10 – Overvoltage cut-off | ||
Preheater Stroco: 7 – Solenoid Valve defective | ||
88 | Y | Preheater Valeo/Webasto: F08 – Fan Motor Defective |
Preheater Eberspaecher: 32/33 – Burner Motor | ||
Preheater Stroco: 6 – Fan defective | ||
89 | Y | Preheater Valeo/Webasto: F09 – Circulation Pump Defective |
Preheater Eberspaecher: N/A (not defined) | ||
Preheater Stroco: N/A (not defined) | ||
90 | Y | Preheater Valeo/Webasto: F10 – Temperature Limiter Defective |
Preheater Eberspaecher: 12/15 – Overheating | ||
Preheater Stroco: 10 – Overtemperature alarm | ||
91 | Y | Preheater Valeo/Webasto: F11 – Igniter Box Defective |
Preheater Eberspaecher: Diagnostic Output Failure | ||
Preheater Stroco: 2 – Ignition Electrode Defective | ||
92 | Y | Preheater Valeo/Webasto: F12 – Error lockout, repeated malfunction / repeated flame out |
Preheater Eberspaecher: 90-97 – Control Box | ||
Preheater Stroco: 9 – Too many start attempts | ||
93 | Y | Missing voltage for main module power 24 V-3 |
94 | Y | Missing CAN message from second unit (articulated systems) |
95 | Y | Missing CAN message from FH first zone/first deck |
96 | Y | Missing CAN message from DP |
97 | R | Hydraulic Pressure High Value |
98 | Y | Clutch 1 fuse failure |
99 | Y | Clutch 2 fuse failure |
100 | Y | Vehicle CAN1 message(s) missing / not valid |
701 | Y | Preheater Valeo/Webasto: F13 – Electrical Pressure Regulator defective (CNG only) |
Preheater Eberspaecher: N/A (not defined) | ||
Preheater Stroco: 5 – Overvoltage | ||
703 | Y | Expansion water tank LOW (HV vehicle battery water circuit) |
704 | Y | Expansion water tank CRITICAL (HV vehicle battery water circuit) |
705 | Y | Expansion water tank HW error (HV vehicle battery water circuit) |
706 | Y | Electrostatic filter clogged |
707 | Y | Electrostatic filter faulty |
709 | Y | High voltage relay 1 damaged (HV DC electric preheater section 1) |
710 | Y | High voltage relay 2 damaged (HV DC electric preheater section 2) |
711 | Y | High voltage relay 3 damaged (HV DC electric preheater section 3) |
712 | Y | High voltage relay 4 damaged (HV DC electric preheater section 4) |