IntelligAIRE III Controller
Pressure Display Module (PDM)
1. |
3-Digit LED Display |
4. |
Discharge Pressure 1 button - compressor 1: Pressing the DISCH 1 button displays the discharge pressure for compressor 1. |
2. |
LED Indicators (above each button) |
5. |
Suction Pressure 2 button - compressor 2: Pressing the SUCT 2 button displays the suction pressure for compressor 2. |
3. |
Suction Pressure 1 button - compressor 1: Pressing the SUCT 1 button displays the suction pressure for compressor 1. |
6. |
Discharge Pressure 2 button - compressor 2: Pressing the DISCH 2 button displays the discharge pressure for compressor 2. |
Drivers Display Module (DDM) (Optional)
1. |
On/Off button |
2. |
3-Digit LED Display |
3. |
Red LED Indicator - HEAT Mode/ |
4. |
Blue LED Indicator - COOL Mode:
|
5. |
Zone 1 Indicator |
6. |
Zone 2 Indicator |
7. |
Zone 3 Indicator |
8. |
Ambient Air Temperature Indicator: The ambient temperature sensor can provide data which may be used to help alert the driver of possible icing conditioning on some road surfaces. |
9. |
Zone Select button - Pressing the Zone Select button will cycle through each enabled zone as well as the outside ambient temperature. |
10. |
Setpoint Indicator |
11. |
Down Arrow button/Up Arrow button - After selecting the Zone Select button (9), the Up and Down Arrow buttons are used to increase or decrease the setpoint temperature for each zone. |
12. |
Percent Indicator |
13. |
Alarm Indicator - Red or Yellow |
14. |
Ambient Light Sensor |
Alarms
When the system is turned ON, the warning indicator will flash as the system powers up.
If YELLOW warning indicator is displayed, the system is operable, but the warning should be investigated as soon as possible. |
|
If RED warning indicator comes ON during operation, the system will shut itself OFF. The system should be checked immediately, as this could indicate a major failure. |
Specifications
APPLICATION |
Control of HVAC unit |
SETUP TEMPERATURE RANGE |
17°C (62°F) to 28°C (82°F) |
Display in °C and °F as firmware option |
|
OPERATING VOLTAGE RANGE |
10 - 32 VDC |
CONTROL PANEL CONTACTORS |
Size 3.7 kW (2 used) - 25 Amps |
Size 1.3 kW (2 used) - 6 Amps |
|
OPERATING TEMPERATURE RANGE |
-40°C (-40°F) to 80°C (176°F) |
CONNECTION |
RS232 serial connection |
CAN bus - CAN0, CAN1 |
|
DIMENSION (WxHxD) |
120 mm x 180 mm x 35 mm (without cover) |
POWER SUPPLY |
Ready 24 VDC |
INPUTS |
Up to 8 - as required by application |
OUTPUTS |
Return Air Temperature |
Evaporator Coil Temperature |
|
Discharge Air Temperature |
|
Compressor Discharge Temperature |
|
Ambient Air Temperature |
|
Battery Cooler Coil Temperature |
|
Water Temperature |
|
DIAGNOSTIC / PROGRAMMING |
CANDiag software |