IntelligAIRE III Controller

Pressure Display Module (PDM)

1.

3-Digit LED Display

4.

Discharge Pressure 1 button - compressor 1:

Pressing the DISCH 1 button displays the discharge pressure for compressor 1.

2.

LED Indicators (above each button)

5.

Suction Pressure 2 button - compressor 2:

Pressing the SUCT 2 button displays the suction pressure for compressor 2.

3.

Suction Pressure 1 button - compressor 1:

Pressing the SUCT 1 button displays the suction pressure for compressor 1.

6.

Discharge Pressure 2 button - compressor 2:

Pressing the DISCH 2 button displays the discharge pressure for compressor 2.

Drivers Display Module (DDM) (Optional)

1.

On/Off button

2.

3-Digit LED Display

3.

Red LED Indicator - HEAT Mode/

4.

Blue LED Indicator - COOL Mode:

  • Blue LED indicator will shine whenever the compressor is running.

  • Red LED indicator will shine whenever the boost pump and coolant valve are operating.

  • Both LED’s will shine when operating in Reheat Mode. Compressor clutch and coolant valve are energized as needed after setpoint is reached to maintain set point.

5.

Zone 1 Indicator

6.

Zone 2 Indicator

7.

Zone 3 Indicator

8.

Ambient Air Temperature Indicator: The ambient temperature sensor can provide data which may be used to help alert the driver of possible icing conditioning on some road surfaces.

9.

Zone Select button - Pressing the Zone Select button will cycle through each enabled zone as well as the outside ambient temperature.

10.

Setpoint Indicator

11.

Down Arrow button/Up Arrow button - After selecting the Zone Select button (9), the Up and Down Arrow buttons are used to increase or decrease the setpoint temperature for each zone.

12.

Percent Indicator

13.

Alarm Indicator - Red or Yellow

14.

Ambient Light Sensor

Alarms

When the system is turned ON, the warning indicator will flash as the system powers up.

If YELLOW warning indicator is displayed, the system is operable, but the warning should be investigated as soon as possible.

If RED warning indicator comes ON during operation, the system will shut itself OFF. The system should be checked immediately, as this could indicate a major failure.

Note Alarm codes can only be cleared using a laptop PC equipped with CANDiag. software. Log alarms should only be cleared after scheduled service has been completed.

Specifications

APPLICATION

Control of HVAC unit

SETUP TEMPERATURE RANGE

17°C (62°F) to 28°C (82°F)

Display in °C and °F as firmware option

OPERATING VOLTAGE RANGE

10 - 32 VDC

CONTROL PANEL CONTACTORS

Size 3.7 kW (2 used) - 25 Amps

Size 1.3 kW (2 used) - 6 Amps

OPERATING TEMPERATURE RANGE

-40°C (-40°F) to 80°C (176°F)

CONNECTION

RS232 serial connection

CAN bus - CAN0, CAN1

DIMENSION (WxHxD)

120 mm x 180 mm x 35 mm (without cover)

POWER SUPPLY

Ready 24 VDC

INPUTS

Up to 8 - as required by application

OUTPUTS

Return Air Temperature

Evaporator Coil Temperature

Discharge Air Temperature

Compressor Discharge Temperature

Ambient Air Temperature

Battery Cooler Coil Temperature

Water Temperature

DIAGNOSTIC / PROGRAMMING

CANDiag software