ClimaAIRE II Controller
1. |
On/ OFF button. |
The Red Alarm (ALARM) symbol will shine in the following two conditions:
In both cases, the unit will switch to the Ventilation Mode. If the Red Alarm appears, alarm code is shown on the display. |
||
The Yellow Alarm (WARNING) symbol will shine in case of temperature sensor failure. If the Yellow Alarm appears, alarm code flashes 5 times on the display. To restart the unit, press the ON/OFF button (1) twice to switch the unit OFF and ON. If the alarm comes up again, don’t restart and see your nearest dealer for service. |
||||
2. |
Display selection button DISPLAY |
The inside temperature in Zone 1 is displayed. | ||
The inside temperature in Zone 2 is displayed. | ||||
The Ambient air temperature is displayed. | ||||
Setpoint icon | ||||
3. |
Mode select button (MODE) (ESCAPE) |
Reheat/Auto mode. The unit will cool or heat the bus automatically (according to thermostat requirements). |
||
A/C mode. The unit will operate in cool mode. |
||||
Heating mode. The unit will operate in heating mode. |
||||
Ventilation mode Only the blowers are operating. |
||||
4. |
Blower speed button (SPEED) (ENTER) |
Automatic blower speed The blowers are controlled automatically depending on the thermostat setpoint and passenger compartment conditions. |
||
High blower speed | ||||
Medium blower speed | ||||
Low blower speed | ||||
5. |
Fresh air select button (AIR MODE) (SMOG) |
Automatic mode – the fresh air damper is controlled automatically | ||
Fresh air damper open (100% FA) | ||||
Half open – fresh air damper at 50% position (50% FA) | ||||
Recirculated air – fresh air damper closed (0% FA) | ||||
6. | Thermostat knob |
To cool the passenger compartment, turn the knob to the LEFT. To warm the passenger compartment, turn the knob to the RIGHT. Display will show adjusted setpoint. The inside temperature range is 17°C - 27°C (63°F - 80°F). |
||
7. | Display |
Operating Instructions
Turn the system ON by pressing button ON/OFF (1).
Use the buttons MODE, SPEED and AIR MODE to adjust the system. By pressing the selection key you select one of the options in the same group.
Use the button DISPLAY to set the display mode.
In Auto Mode all functions are controlled by the ClimaAIRE II controller automatically according to the required setpoint.
Turn the system OFF by pressing key ON/OFF (1).
Specifications
APPLICATION |
Control of HVAC unit |
SETUP TEMPERATURE RANGE |
17ºC (63ºF) to 27ºC (80ºF) |
OPERATING VOLTAGE RANGE |
10 - 32 VDC |
CURRENT CONSUMPTION |
280 mA |
CONNECTOR TYPE |
Packard Metric-Pack |
OPERATING TEMPERATURE RANGE |
-40ºC (-40ºF) to 85ºC (185ºF) |
COMMUNICATION |
CAN J1939 |
DIMMENSIONS (WxHxD) |
187 mm x 57 mm x 45 mm |
POWER SUPPLY |
Ready for 12 VDC and 24 VDC |
DISPLAY MODULE DELUXE |
|
ANALOG INPUT |
1 Feedback Sensor |
BASE MODULE DELUXE |
|
ANALOG INPUTS |
6 Temperature Sensors |
6 Feedback / Temperature Sensors |
|
DIGITAL INPUTS |
6 High Side (action at 12 - 24 V) |
2 Low Side (action at 0 V) |
|
ANALOG OUTPUTS |
4 x 0 - 5 V |
DIGITAL OUTPUTS |
1 x 10 A; 1 x 15 A; 10 x 1 A |
4 x H Bridge Output or 6 Digital outputs 250 mA |
|
DIAGNOSTIC / PROGRAMMING |
RS 232 PORT |