Specifications

Refrigeration System

Contact your Thermo King dealer for refrigeration system service or maintenance.

Electrical Control System

Low Voltage 12.8 Vdc to 48 Vdc
17–36 Vac
Battery Thermo King EnergyONE (880 CCA) AGM battery as standard.
Fuses See your Thermo King Dealer
Battery Charging

Single Temperature as Standard - 12 volt, 37 amp, brush type, Thermo King Alternator

Single Temperature Option - 12 volt, 120 amp, brush type, Thermo King Alternator

Electric Motor

Size/Type Operating Speed Voltage/Phase/Hertz Full Load Amps
9.3 kW Induction 1450 RPM 400 Volt, 3 phase, 50 hertz 19.7 amps
9.5 kW Induction 1740 RPM 460 Volt, 3 phase, 60 hertz 17.1 amps

Standby Power Requirements

Supply Circuit Breaker: A-500E and A-500E Spectrum 32 amps
When connecting from MOA box to main grid
Extension Cord Size:
  • Up to 15 meters (50 feet) — 6 mm2 (10 gauge) per conductor
  • 15 to 22 meters (50 to 75 feet) — 8 mm2 (8 gauge) per conductor
When connecting from Energ-e Pack charging system to main grid
Extension Cord Size:
  • 10 meters (32 feet) maximum - 6 mm2 (10 gauge) per conductor
  • 400V/50Hz/3 phases + neutral

TracKing

Platform ARM Cortex-A8, 300MHz, 256MB RAM, 4GB Flash, Linux
GSM/GPRS 3G, Sierra HL8548
GPS u-blox NEO-7M
Bluetooth Version 4.0 Bluetooth Classic /Bluetooth Low Energy (BLE)
Serial Ports 2 External Serial Ports for TracKing extensions or Third-Party Connect
Operating voltage 12 to 24 V DC
Backup Battery Single cell Li-Ion 3.6V Nominal, 2600mAh, 9.36Wh
Environmental Storage Temperature -40 to +85 C