Unit Capacity

Unit Specifications - Trailer multi-temperatures

    A-500 Spectrum
    Zone 1 Host Unit Zone 2 Remote Evaporator (S3A)
  at ambient Temperature (1) Refrigeration capacity
Refrigerant   R-452A
Capacity on engine power 0 °C 18555 W(NOMINAL) 8901 W(INDIVIDUAL)
–20 °C 9981 W(NOMINAL) 5358 W(INDIVIDUAL)
Capacity on electric standby 0 °C 15359 W(NOMINAL) 8200 W(INDIVIDUAL)
–20 °C 7612 W(NOMINAL) 3949 W(INDIVIDUAL)
Heating capacity –10 °C
–20 °C
       
Airflow volume @ 0 Pa static pressure 5 000 m3/hr 2000 m3/hr
Discharge velocity (Air throw) 15 m/sec 9.5 m/sec
       
Maximum dimensions (2)     5.3 m
(1) at +30°C ambient temperature under ATP conditions
(2) Maximum recommended dimensions: these are guidelines based on airflow and air velocity requirements. For each application, a heat load calculation must be performed. All calculations are based upon the following assumptions: Trailer wall k value = 0.4W/m2K, internal trailer length up to 13.5 m, height up to 2.5 m, width up to 2.5 m, zero heat load from produce carried.