Specifications
Refrigeration System
Contact your Thermo King dealer for refrigeration system service or maintenance.
Compressor
E-400e/E-500e/E–600e | |
---|---|
Compressor Type | Electrical hermetic compressor, rotary type |
Oil Type | PVE |
Electrical Control System
24 Vdc | ||
Fuses | ||
Common Fuses | ||
Fuse 3: Evaporator Fan Motor (EFM1) | 10 amps | |
Fuse 4: Evaporator Fan Motor (EFM2) | 10 amps | |
Fuse 5: Liquid Injection Switch (LIS), Liquid Injection Valve Roadside compressor (LIV1), EVAP1 Defrost Hot Gas Solenoid Valve (PS1), Heat Pilot Solenoid (PS5), Bypass valve (PS7) |
10 amps | |
Fuse 6: Condenser fan for Series / Parallel operation | 7.5 amps | |
Fuse 1: Condenser Fan Motor (CFM1) (located in CF1 wire, in an inline fuseholder, type ATO 32V) | 10 amps | |
Fuse 2: Condenser Fan Motor (CFM2) (located in CF1 wire, in an inline fuseholder, type ATO 32V) | 10 amps | |
Fuse 8: (Spectrum Only) EVAP2 Liquid Solenoid Valve (PS2), EVAP1 Liquid Solenoid Valve (PS3), EVAP2 Defrost Hot Gas Solenoid Valve (PS4), Drain Heaters 3 and 4 (HT3, HT4), UON signal | 10 amps | |
Fuse 9: (Spectrum Only) Evaporator Fan 3 | 10 amps | |
Fuse 10: (Spectrum Only) Evaporator Fan 4 | 15 amps | |
Fuse 11: Drain Heaters (H1 and H2) | 2 amps | |
Fuse 17: Drain Heaters (H3 and H4) (type MINI 32V) | 2 amps | |
Fuse 23: Extra Activation Condenser Fan Motor (CFM2) (type MINI 32V) | 10 amps | |
Fuse 13: Fuse in ePTO OEM connection | 5 amps | |
Fuse 14: Fuse in ePTO OEM connection | 5 amps | |
Fuse 15: Fuse in ePTO OEM connection | 5 amps | |
Condenser Fan Motor | ||
Voltage | 26 Vdc | |
Full Load Current | 4.7 Amps | |
Power Rating | 122 W | |
RPM with Full Load | 3,300 | |
Evaporator Fan Motors (Each) | ||
Voltage | 26 Vdc | |
Full Load Current | 4 Amps | |
Power Rating | 104 W | |
RPM with Full Load | 3,300 | |
Coil for Hot Gas Solenoid (PS1, PS2, PS3, PS4) | ||
Voltage | 24 Vdc | |
Current | 0.6 Adc | |
Coil for Liquid Injection Solenoid (LIS) – MAX Only | ||
Voltage | 24 Vdc | |
Current | 0.6 Adc | |
Coil for Heat Pilot Solenoid (PS5) - Truck Engine Coolant Heat Option Only | ||
Voltage | 24 Vdc | |
Current | 0.6 Adc | |
Resistance | 8.0 ohms | |
Coil for Bypass (PS7) | ||
Voltage | 24 Vdc | |
Current | 0.9 Adc | |
Drain Line Heaters (Each) - MAX Only | ||
Voltage | 24 Vdc | |
Contacts | 0.9 amps ± 5% at 68 F (20 C) | |
Coil Resistance | 13.8 ohms ± 5% at 68 F (20 C) | |
Power Distribution Unit (PDU) | ||
Voltage | 24 Vdc | |
Current | 24 Amps | |
Core Power Module (CPM) | ||
Voltage | 12 VDC/24 VDC | |
Current | 24 Amps |
TracKing
Platform | LTE Cat 1, GSM, Dual Sim ,128MB Flash, IP41 |
GSM/GPRS | |
GPS | |
Bluetooth | Version 4.0 + LE |
Serial Ports | 1 External Serial Ports for TracKing extensions or Third-Party Connect |
Input Power | 10 - 30 V DC with overvoltage protection |
Backup Battery | 170 mAh Li-Ion battery 3.7 V (0.63 Wh) |
Environmental Storage Temperature | -20
°C to +85 °C (without battery) -20 °C to +40 °C (with battery) |
Certification & Approvals | CE-RED, E-mark, Anatel, RCM |