Alarm Code Descriptions
Color Code Definitions
OK TO RUN | CHECK AS SPECIFIED | TAKE IMMEDIATE ACTION |
Alarm | Description | |
---|---|---|
Manual Start | ||
bAt | Low Battery Voltage - Check vehicle battery. | |
Auto Start | ||
HP |
High Pressure Alarm - The system has detected excessively high discharge pressure. If the problem persists when the unit is restarted, contact your Thermo King Dealer. |
|
LP |
Low Pressure Alarm - The system has detected excessively low suction pressure. If the problem persists when the unit is restarted, contact your Thermo King Dealer. |
|
PSE |
High Pressure Sensor Failure - The high pressure sensor has become faulty or disconnected. Contact your Thermo King Dealer. |
|
tEP | Thermal Protection Alarm - If the problem persists when the unit is restarted, contact your Thermo King Dealer. | |
tP4 | CPM error - See CPM LED for alarm and/or Diagnostic tool. | |
dr1, dr2 |
Cargo Doors Are Open (Units with door switch option only) - Check if the Doors are open. if not, then the door switches are faulty, or improper door switch configuration. Contact your Thermo King Dealer. |
|
tCO |
Control Module Overheating If the problem persists when the unit is restarted, contact your Thermo King Dealer. |
|
SOF |
Software Failure Contact your Thermo King Dealer. |
|
P1E |
Faulty Cargo Box Return Air Temperature Sensor - Faulty or disconnected return air temperature sensor. Contact your Thermo King Dealer. |
|
P2E |
Remote Cargo Box Return Air Temperature Reading Error (open circuit or short-circuit) Contact your Thermo King Dealer. |
|
C |
Communications Failure Contact your Thermo King Dealer. |