Superfreezer CRR DF MP3000/MP3000a
- Chapter 1: Safety Precautions
- Chapter 2: Service Guide
- Chapter 3: Specifications
- 3.1: Full Cool Operation Net Cooling Capacity
- 3.2: System Net Defrost Heating Capacity
- 3.3: Evaporator Airflow
- 3.4: R-134a Refrigeration System
- 3.5: R-23 Refrigeration System
- 3.6: Electrical System
- 3.7: Microprocessor Controller
- 3.8: Physical Specifications
- 3.9: Compressor Torque — 3D Copeland Compressor Bolt Torque
- 3.10: Metric Hardware Torque Charts
- Chapter 4: Unit Description
- 4.1: General Description
- 4.2: Operating Modes
- Chapter 5: Operating Instructions
- 5.1: Basic Unit Controls, Instruments and Protection Devices
- 5.2: R-134a Refrigeration System Controls, Instruments and Protection Devices
- 5.3: R-23 Refrigeration System Controls, Instruments and Protection Devices
- 5.4: Pretrip Inspection
- 5.5: Power Selection
- 5.6: Pre-load Operation
- 5.7: Loading Procedure
- 5.8: Post Load Procedure
- 5.9: Starting the Unit on Ship
- 5.10: Post Trip Procedure
- Chapter 6: Microprcessor Controller
- 6.1: General Description
- 6.2: General Theory of Operation
- 6.3: Sequence Of Operation
- 6.4: Changing the Setpoint
- 6.5: Initiating a Manual Defrost
- 6.6: Displaying Alternate Controlling (Supply or Return) Air Sensor Temperature
- 6.7: Displaying Alternate Fahrenheit (F) or Celsius (C) Temperature
- 6.8: Menu Operating Instructions
- Controller Menu
- Data Menu
- Alarm List Menu
- Alarm Types
- Alarm Code States
- Viewing the Alarm List menu:
- Commands Menu
- Viewing the Commands menu:
- Manual function Test, DF units
- Misc. Functions Menu
- Viewing the Misc. Functions menu:
- Setting the Date and Time
- Changing the Temperature Display Value (C/F)
- Setting Cargo Data
- Viewing or Setting Run Time
- Configuration Menu
- MP3000/MP3000a Configuration List, DF Units
- Viewing or Setting Functions in the Misc. Functions menu:
- Datalogger Menu
- Viewing the Datalogger menu:
- RMM State Menu
- Viewing the RMM State screen:
- 6.9: PTI (Pretrip) Test
- 6.10: Temperature Sensors
- 6.11: Manual Emergency Mode Operation
- 6.12: Replacing the EPROM Chip (MP3000/MP3000a)
- 6.13: Replacing the Microprocessor Controller
- 6.14: Flash Loading Controller Software
- Chapter 7: Electrical Maintenance
- Chapter 8: Refrigeration Maintenance
- 8.1: Introduction
- 8.2: Tools
- 8.3: Vacuum Pump
- 8.4: Filters and Cartridges
- 8.5: Refrigerant Recovery Equipment
- 8.6: Detecting Leaks
- 8.7: Special Service Fittings
- 8.8: Oil Acid Test
- 8.9: Checking Compressor Oil
- 8.10: Isolate Compressor
- 8.11: Service Valve Positions
- 8.12: Gauge Manifold Connections
- 8.13: Low Side Pump Down (R-134a Compressor Only)
- 8.14: Gauge Manifold Set
- 8.15: Gauge Manifold Set Installation and Removal
- 8.16: Checking Refrigerant Charge
- 8.17: Receiver Tank Sight Glass
- 8.18: Leak Testing Refrigeration System
- 8.19: Using Pressurized Nitrogen
- 8.20: Recovering Refrigerant from System
- 8.21: Evacuation and Cleanup of Refrigeration System
- 8.21.1: Unit Preparation and Hookup
- 8.21.2: Unit Evacuation
- 8.21.3: Pressure Rise Test
- 8.21.4: Factors Affecting Speed of System Evacuation
- 8.21.5: Heat Saves Time
- 8.22: Charging System with Refrigerant
- 8.23: Compressor Replacement
- 8.24: Condenser Coil Replacement
- 8.25: Filter Drier Replacement
- 8.26: Evaporator Expansion Valve (TXV) Replacement
- 8.27: Expansion Valve Replacement
- 8.28: Heat Exchanger Replacement
- 8.29: Receiver Tank Replacement
- 8.30: High Pressure Cutout Switch Replacement
- 8.31: Liquid Line Solenoid Valve Replacement (R-134a System Only)
- 8.32: Low Pressure Cutout Switch Replacement
- Chapter 9: Servicing the Unit
- Chapter 10: Diagnostics
- 10.1: Introduction
- 10.2: Mechanical Diagnostics
- 10.3: Refrigeration Diagnostics
- 10.4: Alarm Codes, Descriptions and Corrective Actions
- Chapter 11: Diagrams
- 11.1: Diagram Index