Starting the AFAM System
-
Press the F4 key to enter the main menu. Press the F2 or F3 key to scroll to Config menu and press F4 to expand the menu.
-
Press the F2 or F3 key to scroll to Options menu and press F4 to expand the menu.
-
Press the F2 or F3 key to scroll to Controlled Atmosphere (CA) menu and press F4 to enter the menu.
-
Press the F2 or F3 key to select AFAM and Press and hold F4 to accept the selection.
-
Press the F1 key several times to return to the standard display.
-
Press the F4 key to enter the main menu. Press the F2 or F3 key to scroll to Controls menu and Press F4 to expand the menu.
-
Press the F2 or F3 key to scroll to Fresh Air Vent Man menu. Press the F4 key to enter the Fresh Air Vent Man menu.
-
Press the F2 or F3 key to scroll between [OFF] and [AFAM].
-
[OFF]: Vent door closes and/or remains closed. AFAM Delay and AFAM Rate settings disappear.
-
[AFAM]: Controller uses enter AFAM DELAY and AFAM RATE time to adjust FAE door to user setting.
-
-
Press and hold the F4 key with the desired state in the menu line until you are returned to the Controls menu.
-
Press the F1 key several times to return to the standard display.