The various software versions are listed below.
Software Version 2.3.4 100927
Release Date |
Features |
September 2010 |
-
Unit Running No Display.
-
OOCL Unit Features Added for MAGNUM SL 211.
-
RMM+ Added for TAL.
-
Shorter Logging Intervals Default OFF.
-
Index for Event with RMM+.
-
Refer to Software Bulletin MP4000 2.3.4 100927 for details.
|
Software Version 2.3.6 110301
Release Date |
Features |
April 2011 |
-
Cold Treatment (CT) has been added for all prefixes except
OOLU.
-
Multi-Temperature settings has been added for all prefixes
(including OOLU).
-
PTI test only has been added as a selection under the COMMANDS
menu. Test will end after MAINTAINING 0C (32F) TEST is completed.
-
Cold Ambient Battery Issue.
-
Warning Message 39 Battery Error added.
-
PTI Pull Times Logged.
-
Warning 38 HIGH VOLTAGE ON LINE.
-
Power Limit Mode Based on Condenser Temperature.
-
AFAM Door Closes HLX.
-
MTS and CT Disabled after PTI.
-
RMM Enables for UACU Units.
-
Discharge Pressure now in Data Menu.
-
Mode Flags Added.
-
Defrost Termination Temperature and Interval Hours Limited.
-
Trip Start All Temperature Logged.
-
AFAM PTI added.
-
Gas Sensor to be OFF when not selected.
-
Backlight ON.
-
Event Log Available in display.
-
Display timer.
-
Refer to Software Bulletin MP4000 2.3.6 110301 for details.
|
Software Version 2.3.7.0 110608
Release Date |
Features |
June 2011 |
-
Cold Treatment (CT) has been added for all prefixes except
OOLU.
-
MTS and CT Feature selectable.
-
MTS Feature Selects Present Setpoint.
-
USDA Trip Defaults OFF.
-
Dehumidify Improvement.
-
Battery Heater Disabled.
-
Compressor Temperature Reading.
-
Heating Element Type.
-
C to F or F to C Display Change.
-
Viewing Event or Temperature Logs in Display.
-
Refer to Software Bulletin MP4000 2.3.7.0 110608 for details.
|
Software Version 2.3.8.0 110628
Release Date |
Features |
June 2011 |
-
Cold Treatment (CT) has been added for all prefixes except
OOLU.
-
Keypad Lock feature has been added.
-
Refer to Software Bulletin MP4000 2.3.8.0 110628 for details.
|
Software Version 2.4.0.0 111220
Release Date |
Features |
January 2012 |
-
Introduce field tester system tool (8232-010) functionality.
-
Alarm 127 GENERAL UNIT ERROR.
-
Alarm 52 PROBE ERROR.
-
Alarm 120 SUCTION PRESSURE SENSOR ERROR.
-
Alarm 31 LOW PRES CUTOUT.
-
Evaporator Fan Speed Option.
-
MTS Defaulted OFF on Power OFF.
-
COLD Treatment for HL.
-
Humidity Controller.
-
AFAM+, AFAM Disable in Frozen Mode.
-
AFAM Introduced.
-
RMM+ Controller Clock Update.
-
RMM Built in Option.
-
RMM+ Graphics.
-
Refer to Software Bulletin MP4000 2.4.0.0 111220 for details.
|
Software Version 2.4.2.0 120313
Release Date |
Features |
April 2012 |
|
Software Version 2.4.3.0 120628
Release Date |
Features |
June 2012 |
-
RMM Built in Option.
-
Optimize (OPT).
-
Cooling Capacity Surveillance.
-
AFAM PTI Selectable.
-
Humidity Control Fan Change.
-
Humidity and AFAM+ PTI.
-
AFAM+ Auto Configuration.
-
HL AFAM.
-
PTI Aborted Event.
-
Setpoint Range +35C to -40C.
-
SmartPTI Event.
-
SmartPTI Thumbs Up.
-
Refer to Software Bulletin MP4000 2.4.3.0 120628 for details.
|
Software Version 2.5.0.0 121121
Release Date |
Features |
November 2012 |
-
RMM Built in Option.
-
Display Contrast Improvement.
-
Gas Sensor ON/OFF Handling.
-
Humidity Operation.
-
Setpoint Change on Battery.
-
Frozen Optimized Mode.
-
Modbus Handling Changed.
-
Refer to Software Bulletin MP4000 2.5.0.0 121121 for details.
|
Software Version 2.5.1.0 130213
Release Date |
Features |
February 2013 |
-
Alarm 137 Sensor System Overload.
-
Alarm 140 Evaporator Section Too Hot.
-
Alarm 98 Compressor Temperature Sensor Short Circuit.
-
Phase Check.
-
Setpoint of +45.
-
RMM Option.
-
SmartPTI Thumbs Up changed.
-
Refer to Software Bulletin MP4000 2.5.1.0 130213 for details.
|
Software Version 2.5.3.0 130424
Release Date |
Features |
May 2013 |
-
Cold Storage Defrost Feature.
-
SmartPTI Feature.
-
O2 Sensor Calibration AFAM+ PTI.
-
Refer to Software Bulletin MP4000 2.5.3.0 130424 for details.
|
Software Version 3.1.0.0 140612
Release Date |
Features |
June 2014 |
-
Software File Format SIP.
-
Alarm 60 Humidity Sensor.
-
Alarm 68 CO2/O2 Sensor Error.
-
Bulb Mode.
-
Refer to Software Bulletin MP4000 3.1.0.0 140612 for details.
|
Software Version 3.2.0.0 140822
Release Date |
Features |
August 2014 |
|
Software Version 3.4.0.0 150729
Release Date |
Features |
August 2015 |
-
Dry Cargo - New controlling mode.
-
Automatic Dry Cargo option for YML container numbers.
-
Abandon sensor must disable optimized mode.
-
Missing logs - deletion of the first internal log file.
-
Alarm 68 occurs in standby mode.
-
Gas analyzer sensor is powered in standby mode.
-
Capacity limitation activates log flag for CA control.
-
Boot loader must support sip files.
-
Battery surveillance is not discovering open protection circuit.
-
Battery alarms must only occur in PTI.
-
A battery icon has been added to the main screen indicating:
battery full charged, charging or error.
-
Coin battery surveillance.
-
Remove Chill PTI and rename PTI to Full PTI for SUDU prefix.
-
Differentiate set point and controlling temperature.
-
AFAM defaulting for Hapag Lloyd units.
-
Option Changes: RMM Option, SMART PTI Option
-
Refer to Software Bulletin MP4000 Appl 3.4.0.0 Opt 3.4.2.0
150729 for details.
|
Software Version 3.5.0.0 151009
Release Date |
Features |
October 2015 |
-
Dry Cargo - New controlling mode. Implemented in Version 3.3.0
Software.
-
Automatic Dry Cargo option for YML container numbers. Implemented
in Version 3.3.0 Software.
-
Abandon sensor must disable optimized mode. Implemented in
Version 3.3.0 Software.
-
Missing logs - deletion of the first internal log file. Implemented
in Version 3.3.0 Software.
-
Alarm 68 occurs in standby mode. Implemented in Version 3.3.0
Software.
-
Gas analyzer sensor is powered in standby mode. Implemented
in Version 3.3.0 Software.
-
Capacity limitation activates log flag for CA control. Implemented
in Version 3.3.0 Software.
-
Boot loader must support sip files. Implemented in Version
3.3.0 Software.
-
Battery surveillance is not discovering open protection circuit.
Implemented in Version 3.3.0 Software.
-
Battery alarms must only occur in PTI. Implemented in Version
3.3.0 Software.
-
Battery icon. Implemented in Version 3.3.0 Software.
-
Coin battery surveillance. Implemented in Version 3.3.0 Software.
-
Remove Chill PTI and rename PTI to Full PTI for SUDU prefix.
Implemented in Version 3.3.0 Software.
-
Differentiate set point and controlling temperature. Implemented
in Version 3.3.0 Software.
-
AFAM defaulting for Hapag Lloyd units. Implemented in Version
3.3.0 Software.
-
Option Changes: RMM Option - Implemented in Version 3.5.0 Software,
SMART PTI Option - Implemented in Version 3.4.0 Software.
-
Refer to Software Bulletin MP4000 Appl 3.5.0.0 Opt 3.5.0.0
151009 for details.
|
Software Version 3.5.0.0 151103
Release Date |
Features |
November 2015 |
|
Software Version 3.6.0.0 20160128
Release Date |
Features |
February 2016 |
-
AFAM vent door alarm 57.
-
MP4000 tester expansion slot test.
-
Error value for faulty battery.
-
Option Changes: 3.5.1.0: RMM activation for 250 TAL; 3.5.2.0:
RMM activation for TAL, RMM activation for Braun; 3.5.3.0: RMM activation
for Unit 45 (CMA); 3.5.4.0: Smart PTI for Braun; 3.6.0.0: RMM activated
for CMA (unit 1); 3.6.1.0: Cold Store Defrost feature activated.
-
Refer to Software Bulletin MP4000 Appl 3.6.0.0 Opt 3.6.1.0
20160128 for details.
|
Software Version 3.7.0.0 20160404
Release Date |
Features |
February 2016 |
-
AFAM Door Closed on Power OFF.
-
Battery Power Management Enhancements.
-
PTI Performed without Battery.
-
Non Optimized default for CTAU prefix.
-
Bug in Menu on Battery Power.
-
Wall Clock Wakeup System not always turned OFF.
-
Prevent Temperature Below Set Point.
-
Option Changes: 3.7.1.0: Smart PTI activate for Braun BCHU930000,
930001, 930002 BCHU720000, 740000.
-
Refer to Software Bulletin MP4000 Appl 3.7.0.0 Opt 3.7.1.0
20160404 for details.
|
Software Version 3.8.0.0 20160512
Release Date |
Features |
May 2016 |
|
Software Version 3.9.0.0 20160530
Release Date |
Features |
May 2016 |
-
Option File Missing After Power On
-
Option Changes: 3.9.0.0: Smart PTI enabled for TAL units.
-
Refer to Software Bulletin MP4000 Appl 3.9.0.0 Opt 3.9.0.0
20160530 for details.
|
Software Version 3.10.0.0 20160708
Release Date |
Features |
July 2016 |
-
AFAM Door Operation ON Battery Power.
-
PTI would pass with a Faulty Digital Valve.
-
Battery Test added to Brief PTI.
-
Alarm 57 FAE Device Error.
-
ICON or Menu Tree Display Change.
-
Refer to Software Bulletin MP4000 Appl 3.10.0.0 Opt 3.9.0.0
20160708 for details.
|
Software Version 3.11.0.0 20170516
Release Date |
Features |
May 2017 |
-
Missing Temperature Logs (USDA) on Battery Power.
-
Controller Reboot after retrieving download using SD Card.
-
Resetting of USDA Calibration after Flashloading.
-
USDA Calibration Reset Event.
-
Loading of the Wrong Option File.
-
SmartPTI Max Days minimum limit change to 2 days.
-
Option Changes: RMM enabled for the following container numbers:
WHLU740001 to WHLU740200, SZLU989311 to SZLU989810, TEMU925730 to
TEMU926229.
-
Refer to Software Bulletin MP4000 Appl 3.11.0.0 Opt 3.11.0.0
20170516 for details.
|
Software Version 3.13.0.0 20170516
Release Date |
Features |
November 2017 |
-
Optional AVL Full Range Disk 0-225 cmh.
-
Option Changes: Non-Optimized Mode as default for the following
container IDs: TAL TLLU107760 to 107859 and TLLU108060 to 108259;
Smart PTI option for BCHU 083040 to 083049 and BCHU 760015 to 760019.
-
Refer to Software Bulletin MP4000 Appl 3.13.0.0 Opt 3.13.2.0
20170516 for details.
|
Software Version 3.14.0.0 20171220
Release Date |
Features |
January 2018 |
-
High speed fans for TITAN prefix in frozen mode.
-
USDA mode to disable Optimized Mode.
-
Non-optimized mode when dehumidification is on.
-
Pressure sensors are tested when not mounted.
-
Too many battery events in Logger.
-
Controller shutting down.
-
Failing HCPO switch flushing data log.
-
Failing HCPO switch must trigger an alarm.
-
Stop charger when battery level is fully charged.
-
Option Changes: Option file read error triggering user type
change. Debug information has been added to this version to catch
the problem.
-
Refer to Software Bulletin MP4000 Appl 3.14.0.0 Opt 3.14.2.0
20171220 for details.
|
Software Version 3.15.0.0 20180313
Release Date |
Features |
May 2018 |
-
USDA Sensors Defaulting.
-
Energy Data Logging Feature.
-
Conditions to default (return to ON) for the “ENERGY LOGGING”
option.
-
Manually turning ON the Energy Data Logging.
-
Menu Values ENERGY LOGGING screen.
-
Option Changes: Cold store defrost option enabled for prefix
TITU and BXRU; RMM communication enabled for container prefix PCIU
(PIL customer).
-
Refer to Software Bulletin MP4000 Appl 3.15.0.0 Opt 3.15.0.0
20180313 for details.
|
Software Version 3.17.0.0 20180905
Release Date |
Features |
September 2018 |
-
Smart PTI - Auto Acknowledge.
-
Skip Extended Defrost on CT and USDA shipments.
-
The option file read error after installing new firmware has
been resolved.
-
Phase Error is now logged in the event log.
-
Option Changes: RMM communication enabled for container prefix
CICU 827089 – 827106 (TCRC customer).
-
Refer to Software Bulletin MP4000 Appl 3.17.0.0 Opt 3.17.0.0
20180905 for details.
|
Software Version 3.17.0.0 20181022
Release Date |
Features |
October 2018 |
-
Option Changes: Extended set point range -40C to +45C enabled
for prefix ZGRU; Cold store defrost option enabled for prefix ZGRU.
-
Refer to Software Bulletin MP4000 Appl 3.17.0.0 Opt 3.17.2.0
20181022 for details.
|
Software Version 3.19.0.0 20191022
Release Date |
Features |
October 2018 |
-
SMART PTI MAX AGE has disappeared for all the customers
-
No defaulting after temperature set point change
-
Option Changes: Enabled 'Wall Clock Defrost' / 'Cold Store
Defrost' for prefix TYRU ; Smart PTI feature enabled for OERU (OOCL)
; Default to Non Optimized ; RMM and Dry Cargo option for Yang Ming
-
Refer to Software Bulletin MP4000 Appl 3.19.0.0 Opt 3.19.3.0
20191022 for details.
|
Software Version 3.19.0.0 200907
Release Date |
Features |
October 2018 |
-
Option Changes: Option set for ’TYRU’ +45C and defaulting to
Non-optimized ; Option "Frozen Mode - Fan Speed Control" for ID 'ZGRU'
; Option "Frozen Mode - Fan Speed Control" for ID 'TYRU' ; Option
set for CGMU555700-557699 RMM and SmartPti ; Frozen Mode - Fan Speed
Control.
-
Refer to Software Bulletin MP4000 Appl 3.19.0.0 Opt 3.19.9.0
200907 for details.
|
Software Version 3.19.4.0 20200303
Release Date |
Features |
October 2018 |
-
Option Changes: Defaulting to Non-optimized for the following
range of Container ID’s: TLLU 120264 – 120313 ; Extended Set Point
from -40C to +45C for TITU, TCIU and BXRU container prefixes ; Not
be possible to shift from C (Celsius) to F (Fahrenheit) for Container
Prefix ECBU..
-
Refer to Software Bulletin MP4000 Appl 3.19.4.0 Opt 3.19.4.0
20200303 for details.
|
Software Version 3.19.6.0 20200602
Release Date |
Features |
October 2018 |
|
Software Version 3.19.7.0 200624
Release Date |
Features |
October 2018 |
-
Option Changes: CGMU851642–851841, Added Option “Default to
NON-OPTIMIZED ; CGMU851642–851841 added the option to default to non-optimized
controlling when changing temperature setpoint more than 3C or when
the setting is defaulted (>5 days off, after PTI, after firmware flash
load).
-
Refer to Software Bulletin MP4000 Appl 3.19.7.0 Opt 3.19.7.0
200624 for details.
|
Software Version 3.20.0.0 2012100
Release Date |
Features |
October 2018 |
-
Added Refrigerant selection to CONFIG menu
-
Missing Event and Temperature logs bug fixed
-
C/F change event
-
Container ID change text missing
-
Container box property added - Container length and height
-
Option Change: Bulb Mode for OOCL ; Smart PTI Activated for
HL prefixes ; Option set for ’TYRU’ +45C and defaulting to non-Optimized
; Option "Frozen Mode - Fan Speed Control" for ID 'ZGRU' ; Option
"Frozen Mode - Fan Speed Control" for ID 'TYRU' ; Option set for CGMU555700-557699
RMM and Smart PTI ; Frozen Mode - Fan Speed Control ; Flashload Procedures
-
Refer to Software Bulletin MP4000 Appl 3.20.0.0 Opt 3.20.0.0
2012100 for details.
|