Electronic Control System
Thermo King direct drive refrigeration units are composed of a condenser unit, an evaporator unit, a vehicle compressor and a control panel (Incab Control Box) which operates the unit. The Electronic Control System is composed of an Electronic Control Module (located inside the condenser unit) and the In-cab Control Box. This In-cab Control Box allows the truck driver to operate the Thermo King refrigeration unit.
In-cab Control Box
Description of the Electronic Control System
The Electronic Control System has the following characteristics:
-
Auto Start
-
Delayed Start
-
Active Display
-
Low Battery Voltage Alarm
-
Battery voltage value display
-
Unit Control without In-cab Control Box
-
Manual or Automatic Defrost
-
Return Air Temperature Sensor
-
Setpoint Temperature Reading
Auto Start: In case of power shut off, if the unit was on, the unit will come back on again when the power is re-started.
Delayed Start: After an automatic start-up, the unit will remain inactive for few seconds.
Active Display: The In-cab Control Box display is always active except when the unit is disconnected (no power) or when the unit is connected but has been manually switched off from the In-cab Control Box (when there is no active alarm).
Total Hourmeter: Total number of hours the unit is in operation.
Vehicle Compressor Hourmeter: Number of hours the unit has been operating on-the-road.
Low Battery Voltage Alarm: Disconnects the unit when the battery voltage is too low.
Battery voltage value display: The battery voltage value is displayed in the information menu.
Unit Control without In-cab Control Box: The unit can also be operated by the Electronic Control System without the In-cab Control Box, under conditions selected by the In-cab Control Box before it is disconnected.
Manual or Automatic defrost: It is possible to choose between manual or automatic defrost and to select the defrost time interval in auto defrost mode.
Return Air Temperature Sensor: On-screen reading of the temperature in the load compartment.
Setpoint Temperature Reading: On-Screen Setpoint Temperature Reading.
Unit Controls
In-cab Control Box — Display, Keys and Symbols
-
Display. It is always active except when the unit is disconnected (no power) or when the unit is connected but has been manually switched off from the In-cab Control Box. It normally displays the return air temperature.
-
ON/OFF Key. This key is used to start/stop the unit by holding the key down for at least 1 second. Single press for exit to the previous level menu.
-
Set Key. Selects prompt screens and information screens. Single press: enter the next level menu.
-
Up Key. Is used to increase the setpoint temperature, display values, and for menu scroll up.
-
Down Key. Is used to reduce the setpoint temperature, display values, and for menu scroll down.
-
Cool Symbol. The unit is cooling.
-
Heat Symbol. The unit is heating.
-
ºC/ºF Display. Indicates whether the on-screen temperature reading is in degrees Celsius (ºC) or degrees Fahrenheit (ºF).
-
Alarm Symbol. Indicates that there is an alarm in the system.
-
Defrost Symbol. Indicates the evaporator unit is in Defrost Mode.
-
Dot Symbol (decimal). Indicates power presence, only when unit is off.