Specifications

Refrigeration System

Contact your Thermo King dealer for refrigeration system service or maintenance.

Compressor

  V-100/
V-200s
V-200 V-300 V-500/V-600 V-800 V-1000
Compressor Model TK08N QP13 QP15 QP16 QP21 QP25
Displacement (cc) 82 131 146.7 163 215 249
Number of cylinders 6 6 6 6 10 10

Electrical Control System

  12 Vdc 24 Vdc
Fuses
Common Fuses
Fuse 3: Evaporator Fan Motor (EFM1) 15 amps 10 amps
Fuse 4: Evaporator Fan Motor (EFM2) 15 amps 10 amps
Fuse 5: Roadside (Engine) Compressor Clutch (CCL1), Liquid Injection Switch (LIS), Liquid Injection Valve (LIV), EVAP1 Defrost Hot Gas Solenoid Valve (PS1), Compressor Motor Contactor (CMC), Heat Pilot Solenoid (PS5) 20 amps 10 amps
Fuse 14: Vehicle Ignition Switch 5 amps 5 amps
Fuse 30: Condenser Fan Motor (CFM) (located in CF1 wire near terminal strip in condenser section) 16 amps 10 amps
 
V-100/V-200s
Fuse 6: Condenser Fan 1/2 2 amps 2 amps
Fuse 21: Battery Power Supply (located in 2 wire near battery) 30 amps 30 amps
 
V-200/V-300 and Spectrum
Fuse 6: Condenser Fan 1/2 2 amps 2 amps
Fuse 8: (Spectrum Only) EVAP2 Liquid Solenoid Valve (PS2), EVAP1 Liquid Solenoid Valve (PS3), EVAP2 Defrost Hot Gas Solenoid Valve (PS4), Drain Heaters 3 and 4 (HT3, HT4) 20 amps 10 amps
Fuse 9: (Spectrum Only) Evaporator Fan 3 15 amps 10 amps
Fuse 10: (Spectrum Only) Evaporator Fan 4 15 amps 10 amps
Fuse 11: Drain Heaters (H1 and H2) 2 amps 2 amps
Fuse 20: Transformer AC Power Supply (located at compressor motor contactor in condenser section) 4 amps 4 amps
Fuse 21: Battery Power Supply (located in 2 wire near battery) 40 amps 40 amps
 
V-500/V-600 and Spectrum
Fuse 6: Condenser Fan 1/2 10 amps 7.5 amps
Fuse 8: (Spectrum Only) EVAP2 Liquid Solenoid Valve (PS2), EVAP1 Liquid Solenoid Valve (PS3), EVAP2 Defrost Hot Gas Solenoid Valve (PS4), Drain Heaters 3 and 4 (HT3, HT4) 20 amps 10 amps
Fuse 9: (Spectrum Only) Evaporator Fan 3 15 amps 10 amps
Fuse 10: (Spectrum Only) Evaporator Fan 4 15 amps 10 amps
Fuse 11: Drain Heaters (H1 and H2) 2 amps 2 amps
Fuse 17: Drain Heaters (H3 and H4) 2 amps 2 amps
Fuse 20: Transformer AC Power Supply (located at compressor motor contactor in condenser section) 4 amps 4 amps
Fuse 21: Battery Power Supply (located in 2 wire near battery) 50 amps (Single Temp) 60 amps (Multi-Temp)
Fuse 31: Condenser Fan Motor 2 (CFM2) (located in CF2 wire near terminal strip in condenser section) 16 amps 10 amps
 
 
V-800, V1000 and Spectrum
Fuse 1: Condenser Fan Motor (CFM1) 15 amps 10 amps
Fuse 2: Condenser Fan Motor (CFM2) 15 amps 10 amps
Fuse 3: Evaporator Fan 1 15 amps 10 amps
Fuse 4: Evaporator Fan 2 15 amps 10 amps
Fuse 5: PS1, PS7, CMC, LIV,PS5, RCV, CCL 20 amps 10 amps
Fuse 10: (Spectrum Only) Evaporator Fan 4 15 amps 10 amps*
Fuse 6: Drain Heaters 1/2 2 amps 2 amps
Fuse 8: (Spectrum Only) EVAP2 Liquid Solenoid Valve (PS2), EVAP1 Liquid Solenoid Valve (PS3), EVAP2 Defrost Hot Gas Solenoid Valve (PS4), Drain Heaters 3 and 4 (HT3, HT4) 20 amps 10 amps
Fuse 9: (Spectrum Only) Evaporator Fan 3 15 amps 10 amps
Fuse 10: (Spectrum Only) Evaporator Fan 4 15 amps 10 amps*
Fuse 11: Drain Heaters (H3 and H4) 2 amps 2 amps
Fuse 14: Ignition 5 amps 5 amps
Fuse 17: TracKing 5 amps 5 amps
Fuse 20: Transformer AC Power Supply 5 amps
(time delay fuse)
5 amps
(time delay fuse)
Fuse 21: Battery Power Supply (located in 2 wire near battery) 1000 amps 60 amps
Fuse 41: Evaporator Fan 5 11 amps 10 amps
Fuse 41: Evaporator Fan 6 11 amps 10 amps
Note * 15 A in Spectrum Versions with Double Evaporator Fan 4
Condenser Fan Motor (All except V-800/V-1000)
Voltage 13 Vdc 26 Vdc
Full Load Current 10 Amps 4.7 Amps
Power Rating 130 W 122 W
RPM with Full Load 2,800 2,800
       
Condenser Fan Motor (V-800/V-1000)
Voltage 9–15 Vdc 16–32 Vdc
Full Load Current 11 Amps 10 Amps
Power Rating 145 W 240 W
Control Voltage Range 1–10 Vdc 6.5–10 Vdc
       
Evaporator Fan Motors (All except ES–800/ES–1000)
Voltage 13 Vdc 26 Vdc
Full Load Current 7.5 Amps 4 Amps
Power Rating 97.5 W 104 W
RPM with Full Load 2,800 2,800
       
Evaporator Fan Motors (ES–800/ES–1000)
Voltage 14 Vdc 28 Vdc
Full Load Current 5.7 Amps 3.4 Amps
RPM with Full Load 2,350 2,430
Speed control 0 to 10 Vdc 0 to 10 Vdc
Type Brushless DC motor Brushless DC motor
       
Transformer (All except V-800/V-1000)
Power 500 VA
Frequency 50/60 Hz
Primary Inputs 115-208-230 Vac
Secondary Nominal Voltage 11.7 Vac (21.4 Amps)
       
Transformer (V-800/V-1000)
Power 1100 VA
Frequency 50/60 Hz
Primary Inputs 230–400 Vac
Secondary Nominal Voltage 2 windings: 11.7 Vac (47 Amps) and 11.7 Vac (47 Amps)

Electric Motor (Model 50)

AC Electric Compressor Motors and Overload Relays
Voltage/Phase/Frequency Horsepower Kilowatts RPM Full Load (amps) Overload Relay Setting (amps)
V-100/V-200s
230/1/50 2.0 1.5 1750 5.4 5.5
V-200/V-300
230/1/50 2.0 1.5 1750 8.6 8.6
230/1/60 2.0 1.5 1750 9 9
230/3/60 2.4 1.8 1750 6.9 6.9
400/3/50 2.4 1.8 1750 4 4
400/3/60 2.4 1.8 1750 4 4
V-500/V-600 (Semi hermetic Standby compressor)
115/1/60 1.5 1.1 1710 14 14
208/1/60 2.0 1.5 1740 9.5 9.5
230/1/60 2.0 1.5 1750 9 9
208/3/60 2.4 1.8 1730 7.2 7.2
230/3/60 2.4 1.8 1750 6.9 7
V-800 (Semi hermetic Standby compressor)
230/3/50 3 2.3 1450 57/16.6 amps 18
400/3/50 3 2.3 1450 32.9/9.6 amps 14
230/3/60 3 2.3 1740 68.4/19.9 amps 18
400/3/60 3 2.3 1740 39.5/11.5 amps 14
V-1000 (Semi hermetic Standby compressor)
230/3/50 5 3.7 1450 22/109 amps 24
400/3/50 5 3.7 1450 12.7/63.1 Amps 16
230/3/60 5 3.7 1740 26.5/121 Amps 24
400/3/60 5 3.7 1740 15.3/70.1 amps 16

TracKing

Platform ARM Cortex-A8, 300MHz, 256MB RAM, 4GB Flash, Linux
GSM/GPRS 3G, Sierra HL8548
GPS u-blox NEO-7M
Bluetooth Version 4.0 Bluetooth Classic /Bluetooth Low Energy (BLE)
Serial Ports 2 External Serial Ports for TracKing extensions or Third-Party Connect
Input Power 12V Nominal
Backup Battery Single cell Li-Ion 3.7V Nominal, > 2Ah
Environmental Storage Temperature -40 to +85 C