Automatic Zone Scrolling
When the Standard Display is shown, the operating conditions for each zone will automatically be shown for 10 seconds. At the end of that time, the next zone will appear on the display.
-
If a zone is currently turned on, the box temperature and setpoint for that zone will be shown.
Important On Multi-Temperature units, Zone 1 can be turned off while the unit is running. The unit will continue to run with Zone 1 turned off. -
If a zone is turned off, dashes will be shown instead of the box temperature and setpoint for that zone.
-
If a zone is in defrost, the LED indicator next to the Defrost Key will be illuminated when that zone is shown on the display.
-
Unit operating conditions are shown by the LED indicators next to the Cycle Sentry Key, High Speed Lock-out Key, and Pretrip Test Key.
In the example ( Multi-Temperature Standard Display), Zone 1 is being shown as indicated by the single horizontal bar to the left of the box temperature. The box temperature of -8.2°F (-22.3°C) and setpoint of -10°F (-23.3°C) indicate that Zone 1 is turned on. Since the Cycle Sentry LED is turned off, the unit operating in Continuous Mode. The illuminated LED next to the High Speed Lock-out Key indicates that high speed operation is locked out. The absence of the Alarm Icon indicated that no alarm conditions exist.