Installation Qualification

Prepared for Thermo King, for validation of temperature controlled equipment Trailer Single-Temperature with units A400, A500 and A–500e.

For each individual equipment (ATP certified body + Thermo King refrigerated unit) a specific TK PharmaSolutions - IQOQ Check-MUL document has to be completed by the Thermo King official dealer to confirm that Installation Qualification conforms to the requirements of the Design Qualification:

GDP-TK-DQ-TRA-ST. The latest valid revision of this document has to be used and is available from Thermo King EMEA InfoCentral intranet.

The vehicle has been inspected and conforms to the design qualification document GDP-TK-DQ-TRA-ST. Photographic evidence is available on request.

  • Airflow is configured for Diesel Pulldown and Steady State = HIGH and Electric Pulldown and Steady State = MAXIMUM.

  • Minimal distances comply with GDP-TK-DQ-TRA-ST Figure “Recommended minimal distances”.

  • Door switches are recommended as described in GDP-TK-DQ-TRA-ST. If installed, the unit should be configured to force UNIT NULL when opening the doors.

  • Thermal curtains are recommended as described in GDP-TK-DQ-TRA-ST.

  • A temperature datalogger as described in GDP-TK-DQ-TRA-ST with at least one sensor in the cargo zone is installed and configured as per customer settings.

  • If double stack system with individual beams is used there should be allowance for air to be correctly distributed around the cargo on both levels.