Introduction

Thermo King designs and builds temperature-controlled transport equipment.

These types of equipment can be validated for a specific desired temperature range for the transport of pharmaceutical products.

Due to the fact that several test were performed on the different units in time, not all the tests are performed under the same circumstances.

Overview: tests performed with transversal layout

Unit Ambient Temperature Set Temperature Door Openings Failure Test Hot and Cold Spots
E-200 Max Spectrum
Zone 1: Zone 2= 50%:50%

‐30°

‐20°

‐10°

+15°

+40°

+4 °C

+20°C

1 and 5 min.

‐‐

1 and 5 min.

‐‐

1 and 5 min.

Done

Done

Done

Done

Done

‐‐
V300 Max Spectrum (IR)
Zone 1: Zone 2= 20%:80%

‐30°

+15°

+40°

+6 °C

+20°C

‐‐

‐‐

15 min.

‐‐

‐‐

Done

‐‐
V500 Max Spectrum (IR)
Zone 1: Zone 2= 60%:40%

‐30°

+15°

+40°

+6 °C

+20°C

2 and 5 min.

2, 5 and 15 min.

2 and 15 min.

Done

Done

Done

‐‐
V800 Max Spectrum (IN)
Zone 1: Zone 2= 50%:50%

‐30°

+45°

+5 °C

+20°C

5 and 10 min.

5 and 10 min.

Done

Done

Done
V300 Max Spectrum (IN)
Zone 1: Zone 2= 60%:40%

‐20°

+35°

+5 °C

+20°C

1 and 2 min.

1 and 2 min.

Done

‐‐

‐‐

Overview tests performed

Unit Ambient temp Set temp Door openings Failure test Hot and Coldspot
T-800R +40°C, -30°C +20°C, +5 °C, -25°C 5 min and  10 min + +
T-1000R +45°C , +40°C, -30°C +20°C, +5 °C, -25°C 5 min and  10 min + -. 
T-1200R  Intermodal +40°C, -30°C +20°C, +5 °C, -25°C - - -
UT-1200R +45°C, +40°C, -30°C +20°C, +5 °C, -25°C 2, 5 and  10 min + +

Overview tests performed

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max deviation of Setpoint
Temperature between ‐20°C +40°C / ‐25°C ‐25°C ‐1/+0.5°C of setpoint
Temperature between +2°C and +8°C +40°C / ‐25°C +5°C ‐/+0.5°C of setpoint
Temperature between +15°C and +25°C +40°C / ‐25°C +20°C ‐/+1 °C of setpoint

Overview tests performed

Temperature Range Extreme Ambient Temperature ZONE 1 setpoint Max Setpoint deviation ZONE 1 ZONE 2 setpoint Max Setpoint deviation ZONE 2
Temperature below -20°C +43°C ‐23°C +3°C /-3°C of setpoint off -
-30°C -23°C +1°C /-1°C of setpoint off -
Temperature between +2°C and +8°C +45°C +5°C +2°C /-2.5°C of setpoint off -
-30°C +5°C +1°C /-2.5°C of setpoint off -
Temperature between +15°C and +25 °C +45°C +20°C +1°C /-1 °C of setpoint off -
-30°C +20°C +1°C /-3 °C of setpoint off -
Temperature below -20°C -30°C -23 °C +2°C /-2 °C of setpoint +5°C +2°C /-2°C of setpoint
+20°C +3°C /-3°C of setpoint
+45°C -23 °C +3°C /-1 °C of setpoint +5°C +3°C /-3°C of setpoint
+20°C +3°C /-2°C of setpoint
Temperature between +2°C and +8°C +45°C +5°C +2°C /-1 °C of setpoint +20°C +1°C /-2°C of setpoint
+40°C +5°C +2°C /-1.5 °C of setpoint -25°C +1°C /-3°C of setpoint
-30°C +5°C +2°C /-2 °C of setpoint +20°C +4°C /-4°C of setpoint
Temperature between +15°C and +25 °C +45°C +20°C +1°C /-1 °C of setpoint +5°C +2°C /-2°C of setpoint
-30°C +20°C +1°C /-2 °C of setpoint +5°C +2°C /-2°C of setpoint

Trailer Body with SLXi Spectrum / SLXe Spectrum PTC

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max deviation of Setpoint
Temperature between ‐20°C +40°C / ‐30°C ‐25°C +4/‐3°C of setpoint
Temperature between +2°C and +8°C +40°C / ‐30°C +6°C +2/‐3°C of setpoint
Temperature between +15°C and +25°C +40°C / ‐30°C +20°C +3/‐4°C of setpoint

Trailer Body with SLXe Spectrum / SLX Spectrum ETV

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max deviation of Setpoint
Temperature between ‐20°C +40°C / ‐30°C ‐25°C +5/‐2°C of setpoint
Temperature between +2°C and +8°C +40°C / ‐30°C +6°C +2/‐3°C of setpoint
Temperature between +15°C and +25°C +40°C / ‐30°C +20°C +/‐4°C of setpoint

Test Results - Trailer Body of 13.6 m with SLXi 300

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max deviation of Setpoint
Temperature between 15°C and 25°C +45°C / ‐30°C +20°C +/‐1°C of setpoint
Temperature between +2°C and +8°C +45°C / ‐30°C +5°C +/‐1°C of setpoint
Temperature below ‐20°C +40°C / ‐30°C –25°C +/‐3°C of setpoint

Test Results - Trailer Body of 13.6 m with SLXe 300

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max deviation of Setpoint
Temperature between 15°C and 25°C +45°C / ‐30°C +20°C +/‐2°C of setpoint
Temperature between +2°C and +8°C +45°C / ‐30°C +4°C +/‐2°C of setpoint
Temperature below ‐20°C +45°C / ‐30°C –25°C +1/‐3°C of setpoint

Test Results - Truck body of 42m3 with T-800R

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max deviation of Setpoint
Temperature between +15°C and +25°C +40°C / ‐30°C +20°C +/-4°C of set point
Temperature between +2°C and +8°C +40°C / ‐30°C +5°C +/-3°C of set point
Temperature between ‐20°C +40°C / ‐30°C ‐25°C +2°C/-4°C of set point

Test Results - Truck body of 48m3 with T-1000R

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max deviation of Setpoint
Temperature between +15°C and +25°C +45°C / -30°C +20°C +/-2°C of set point
Temperature between +2°C and +8°C +40°C / ‐30°C +5°C +/-2°C of set point
Temperature between ‐20°C +40°C / ‐30°C ‐25°C +/-4°C of set point

Test Results - Truck body of 46m3 with UT-1200R

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max deviation of Setpoint
Temperature between +15°C and +25°C +45°C / -30°C +20°C +2/-1°C of set point
Temperature between +2°C and +8°C +45°C / -30°C +5°C +2/-2°C of set point
Temperature between ‐20°C +45°C / -30°C ‐25°C +2/-3°C of set point

Test Results – 45 feet container with T-1200R 

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max deviation of Setpoint
Temperature between +15°C and +25°C +40°C / ‐30°C +20°C +/-2°C of set point
Temperature between +2°C and +8°C +40°C / ‐30°C +5°C +2/-1°C of set point
Temperature between ‐20°C +40°C / ‐30°C ‐25°C +/-4°C of set point

Truck body with T-1000R Spectrum S3+S3

Temperature Range

Extreme Ambient Temperature

Recommended Setpoint

Max Average Deviation from Setpoint

Temperature between 2°C and 8°C

+40°C / -30°C

+6°C

+2/-3°C of setpoint

Temperature between 15°C and 25°C

+40°C / -30°C

+20°C

+2/-3°C of setpoint

Truck body with T-1200R Spectrum S3+S3

Temperature Range

Extreme Ambient Temperature

Recommended Setpoint

Max Average Deviation from Setpoint

Temperature below -20°C

+40°C / -30°C

-25°C

+5/-5°C of setpoint

Temperature between 2°C and 8°C

+40°C / -30°C

+6°C

+2/-4°C of setpoint

Temperature between 15°C and 25°C

+40°C / -30°C

+20°C

+3/-5°C of setpoint

Truck body with UT-1200 Spectrum S3+S3

Temperature Range

Extreme Ambient Temperature

Recommended Setpoint

Max Average Deviation from Setpoint

Temperature between 2°C and 8°C

+40°C / -30°C

+6°C

+3/-3°C of setpoint

Temperature between 15°C and 25°C

+40°C / -30°C

+20°C

+3/-5°C of setpoint

Truck body with Truck body with UT-R Spectrum S3+S3

Temperature Range

Extreme Ambient Temperature

Recommended Setpoint

Max Average Deviation from Setpoint

Temperature above -27°C

+30°C / -30°C

-29 °C

+/- 3°C of setpoint

Temperature below -20°C

+40°C / -30°C

-24 °C

+4/-6°C of setpoint

Temperature between 2°C and 8°C

+40°C / -30°C

+5°C

+/-3°C of setpoint

Temperature between 15°C and 25°C

+40°C / -30°C

+20°C

+/-5°C of setpoint

Truck body with Thermo King UT-R Spectrum unit

Temperature Range Extreme Ambient Temperature Recommended Setpoint Max Average Deviation from Setpoint

Temperature above -27°C

+30°C / -30°C

-29 °C

+/-3°C of setpoint

Temperature below -20°C

+40°C / -30°C

-24 °C

+4/-6°C of setpoint

Temperature between 2°C and 8°C

+40°C / -30°C

+5°C

+/- 3°C of setpoint

Temperature between 15°C and 25 °C

+40°C / -30°C

+20 °C

+/- 5°C of setpoint

Overview tests performed

Climate Controlled Room (CCR) temperature Setpoint Test Type Test
7.5 °C 32.5 °C A K coefficient equal to or less than 0.40W/m–2k-1 is required. If not, tests with setpoint above 0 °C can only be completed. K
-30 °C 20 °C Stability Test (2.5 hours) (Electric/ Continuous) E01
-30 °C 20 °C Doors Opening 7 min E02
-30 °C 20 °C Failure Mode E03
-30 °C 5 °C Stability Test (2.5 hours) (Electric/ Continuous) E04
-30 °C 5 °C Doors Opening 7 min E05
-30 °C 5 °C Failure Mode E06
-30 °C -22 °C Stability Test (2.5 hours) (Electric/ Continuous) E07
30 °C -25 °C Stability Test (2.5 hours) (Electric/ Continuous) E08
30 °C -25 °C Doors Opening 3 min E09
30 °C -25 °C Failure Mode E10
45 °C 5 °C Stability Test (2.5 hours) (Electric/ Continuous) E11a
45 °C 5 °C Doors Opening 7 min E12
45 °C 5 °C Failure Mode E13
45 °C 20 °C Stability Test (2.5 hours) (Electric/ Continuous) E14a
45 °C 20 °C Doors Opening 7 min E15
45 °C 20 °C Failure Mode E16
50 °C 20 °C Stability Test (2.5 hours) (Electric/ Continuous) E14b
50 °C 4 °C Stability Test (2.5 hours) (Electric/ Continuous) E11b

Test Results – IN Truck body of 5.21m3 with V-200 MAX

Extreme Ambient Recommended Setpoint Permitted Deviation from Setpoint Temperature Managemant
Min Max
-30 °C 20 °C 17.0 °C 23.0 °C +15 °C to +25 °C
-30 °C 5 °C 3.0 °C 7.0 °C +2 °C to +8 °C
-30 °C -22.5 °C -25.0 °C -22.0 °C Above -20 °C
30 °C -25 °C -25.0 °C -22.0 °C Above -20 °C
50 °C 20 °C 17.0 °C 23.0 °C +15 °C to +25 °C
50 °C 4 °C 2.1 °C 7.0 °C +2 °C to +8 °C

Note To ensure total flexibility the qualification is to be performed at all stated ranges from above.