Risk Reporting Matrix
Thermo King used the risk reporting matrix (see below figure) to identify and classify potential problems while using the specific transport equipment:
-
A 2 zone IR body (0.4 W/m2.K or better insulation) equipped of a Thermo King refrigerated unit V-300 MAX Spectrum ES150+ES150, V-500 MAX Spectrum ES300+ES300 or V-800 MAX Spectrum. ES400+ES400.
-
A 2 zone IN body (0.7 W/m2.K or better insulation) equipped of a Thermo King refrigerated unit V-300 MAX Spectrum ES200+ES100.
Thermo King used the risk reporting matrix (see below figure) to identify and classify potential problems while using the specific transport equipment:
-
a refrigeration body type (van/truck) with similar or better insulation than ATP IN standards (0.7W/m2. K) and equipped with a refrigerated unit type Thermo King Single-Temperature (V-200 MAX 30/50).
Thermo King used the risk reporting matrix (see below figure) to identify and classify potential problems while using the specific transport equipment:
-
a refrigeration trailer body type with similar or better insulation than ATP standards (0.4W/m².K) and equipped with a refrigerated unit type Thermo King A400, A500 or A-500e Single-Temperature.
Thermo King used the risk reporting matrix (see below figure) to identify and classify potential problems while using the specific transport equipment:
-
a refrigeration trailer body type with similar or better insulation than ATP-FRC standards (0.4W/m2.K), and equipped with a refrigerated unit type Thermo King multi-temperatures unit A-500 Spectrum with S3A remote evaporator
Thermo King used the risk reporting matrix (see below figure) to identify and classify potential problems while using the specific transport equipment, a refrigeration trailer type ATP (FRC) certified (0.4 W/m².K or better insulation) with a refrigerated unit type Thermo King multi-temperature (SLXi Spectrum S3, SLXi Spectrum S6, SLXe Spectrum S3 PTC, SLXe Spectrum S6 PTC, SLXe Spectrum S3, SLX Spectrum ETV S3, SLXe Spectrum S6, SLX Spectrum ETV S6) for the transport of medicinal products.
Thermo King used the risk reporting matrix (see below figure) to identify and classify potential problems while using the specific transport equipment, a refrigeration trailer type ATP (FRC) certified (0.4 W/m².K or better insulation) with a refrigerated unit type Thermo King SLX(e) single-temperature (SLXi300, SLXi400; SLXe300, SLXe400; SLX300 and SLX400) for the transport of medicinal products.
Thermo King used the risk reporting matrix (see below figure) to identify and classify potential problems while using the specific transport equipment:
-
a refrigeration body type (truck) with similar or better insulation than ATP standards (0.4W/m2.K), and equipped with a refrigerated unit type Thermo King T-series SingleTemperature (T-1000R, T-1200R and UT-1200).
-
a refrigeration body type (truck) with similar or better insulation than ATP standards (0.49W/m2.K), and equipped with a refrigerated unit type Thermo King T-series SingleTemperature T-800R.
-
a refrigeration body type (container ) with similar or better insulation than ATP standards (0.4W/m2.K), and equipped with a refrigerated unit type Thermo King T-series SingleTemperature (T-1200R Intermodal)
Thermo King used the risk reporting matrix (see below figure) to identify and classify potential problems while using the specific transport equipment:
-
A 2 zones IR body (0.4 W/m2.K or better insulation) equipped of a Thermo King refrigerated unit T-1000R Spectrum S3+S3, T-1200R Spectrum S3+S3 or UT-R Spectrum S3+S3.
-
A 2 zones IN body (0.7 W/m2.K or better insulation) equipped of a Thermo King refrigerated unit UT-1200 Spectrum S3+S3.