Connecting to a Third Party Device
All SLXi trailer units come fitted as standard from factory with a Low Voltage Disconnect (LVD) switch to accommodate for 3rd party device connections. The LVD switch ensures that all SLXi units provide a dedicated device connection point for external devices, while also preventing battery discharge/depletion of the EnergyONE battery during unit idle periods.
LVD Switch
The function of the LVD switch is as follows:
-
Disconnects power to external devices when battery voltage drops below 12.1V (for longer than five minutes).
-
Automatically resets when system voltage rises above 13V (for longer than 10 seconds).
-
Provides connection point in control box for up to three external devices.
-
Recommended total maximum current draw from all connected devices combined (At all times, not just when the unit is power down): 2 Amps.
-
Excessive current draw due to external devices when unit is powered down will result in the LVD switch disconnecting the output after a short period of time (possibly within hours - depending on total current draw).
-