Switching from Electric to Diesel

Note Units equipped with the Electric Standby option only.

If the Electric to Diesel Autoswitch Enabled feature in Guarded Access is set YES, the unit will automatically switch to Diesel Mode operation when standby power is turned off or is no longer available.

If the Electric to Diesel Autoswitch Enabled feature in Guarded Access is set NO, the prompt screen ( Prompt Screen) will appear when standby power is turned off or is no longer available. Alarm Code 91 Check Electric Ready Input and Alarm Code 84 Restart Null will both be set.

Prompt Screen

Turn the unit off and back on using the OFF and ON Keys. This will clear Alarm Code 91 Check Electric Ready Input and Alarm Code 84 Restart Null.

Note The CLEAR Soft Key will not clear these two alarms. The prompt screen shown ( Prompt Screen) will appear.

Prompt Screen

If YES is selected, the display will briefly show the programming screen ( Programming Screen). Diesel Mode operation will briefly be confirmed.

Programming Screen

If unit operation is required, the diesel engine will start as shown previously in Starting The Diesel Engine.