Navigating Controller Operating Menu

1 Main Menu display    
2 Navigation Key    

Menu Scrolling Keys

Moving through these menus, their submenus, and entering commands requires the use of these below keys:

ENTER - Press the Enter key to enter a new menu or submenu.
EXIT - Press the Esc key each time you want to exit a submenu shown in the message display.
UP - Press the Up key each time you want to scroll up in a menu or submenu shown in the Message Display; or scroll forward in a menu line.
DOWN - Press the Down key each time you want to scroll down in a menu or submenu shown in the Message Display; or scroll backward in a menu line.

The MP-5000 contains an extensive operating menu. The menu is navigated via the controller keypad.

  1. The Main menu is divided into seven major areas that can be navigated via keypad.

Navigation Icon

A solid fill in the arrow indicates more screens available. Use Up/Down keys to move to next or prior screen.

Lock Padlock

If PADLOCK is active, contact technician, the technician must enter correct key (number) to unlock display. PADLOCK OPTION must be selected ON under the CONFIGURATION/ UNIT SETTING for it to be active or visible.

F1 Menu

The F1 Menu is activated by pressing the F1 key in Function Key.

 

A list of F1 Menu commands are available:

  • Defrost Command

  • PTI Commands

  • Main Menu

  • Link

  • Language

  • USB

Initiating a Manual Defrost

Turn the UNIT ON. Allow Unit to start and stabilise.

Complete the following steps:

  1. Press the F1 function key.

  2. Select the Defrost Commands option and press enter.

    Defrost Menu

  3. Select Start Defrost to start the defrost. If the unit operating conditions allow a manual defrost (e.g., evaporator coil temperature is less than 18 C [64 F]), the unit enters Defrost.

  4. The defrost cycle automatically terminates and returns the unit to normal operation.

Pretrip Inspection (PTI)

Turn the UNIT ON. Allow Unit to start and stabilise.

Complete the following steps:

  1. Press the F1 function key.

  2. Use Down arrow key to select the PTI Commands. Press Enter key to see the PTI Commands options.

  3. Press the Up/Down arrow keys to scroll between the PTI Command options to select from the different PTI test, Press Esc key to exit.

Link

Link menu will display the QR code to access the literature files.

To access the Link menu follow the below instructions:

  1. Press the F1 function key.

  2. Use Down arrow key to select the Link menu.

  3. Press Enter key to view the QR code.

  4. Scan the QR code to access to associated literature files.

Language

The Language menu allows the user to view and choose a language from the available list. User can select a language from the available list at one time. All subsequent displays are shown in the selected language. English is the default language.

Language menu can be accessed from F1 function key.

To select the required language, follow the below instructions:

  1. Press the F1 function key.

  2. Use Down arrow key to select the language menu.

  3. Press Enter key to view the different language option available.

  4. Press the Up and Down arrow keys to scroll between the different language options.

  5. Press the Enter key to select a required language.

    All subsequent displays are shown in the selected language.

    Note If no key is pressed for 3 minutes, language goes back to default language English (unless special Software with container prefix set).

Viewing Alarms/ Warnings

To view the alarms that are present, turn the UNIT ON. Allow Unit to start and stabilise.

  1. Press the ALARM KEY. The Alarm List appears.

  2. Press the Up/Down keys to scroll between Alarms that are present.

  3. Press the Enter key to acknowledge the Alarm. Press Esc key to exit.

Display Alternate Fahrenheit (F) or Celsius (C) Temperatures

To view the alarms that are present, turn the UNIT ON. Allow Unit to start and stabilise.

Complete the following step:

The controller can display temperatures in Celsius or Fahrenheit. Press the C/F function key display will change to C or F. Some customers do not allow the display to be change permanently.

Changing Setpoint

To change the controller setpoint, turn the UNIT ON. Allow Unit to start and stabilise.

Complete the following steps:

  1. Press the Setpoint key in the Functional keys. The Setpoint Change menu appears.

  2. Press ENTER key to change required temperature.

  3. Press UP or DOWN keys to increase or decrease setpoint.

  4. Press the Up/Down keys to scroll the Setpoint Up or down - depending on your required Temperature.

  5. Press and hold the ENTER key until you are returned to the main Screen. The new setpoint is recorded in the controller and appears in the display.

Controller Back-up Battery

Every Controller has a Back-up Battery. This will allow the controller to be energized if the unit is not connected to shore power. The technician can change settings in the controller - Setpoint, etc.

Press the ON/OFF key, the controller will energize and stay energized for 25 sec, by pressing any of the Menu keys the 25 sec timer will reset to 20 sec.