Refrigeration System

All refrigeration service requirements, major and minor, should be handled by a Thermo King dealer.

Refrigeration System C-Series

Refrigerant Charge:

C-150

C-150 10

C-150 10 MAX

C-150 30 MAX


C-250

C-250 10

C-250 10 MAX

C-250 30 MAX


C-350

C-350 10

C-350 10 MAX

C-350 30 MAX


C-450

C-450 10

C-450 10 MAX

C-450 30 MAX


C-550

C-550 10

C-550 10 MAX

C-550 30 MAX


C-650

C-650 10

C-650 10 MAX

C-650 30 MAX


C-750 10 MAX

C-750 30 MAX

1.54 lb (0.70 kg) R-134a

1.54 lb (0.70 kg) R-134a

1.54 lb (0.70 kg) R-404A

1.54 lb (0.70 kg) R-404A


2.09 lb (0.95 kg) R-134a

2.09 lb (0.95 kg) R-134a

2.09 lb (0.95 kg) R-404A

2.09 lb (0.95 kg) R-404A


2.64 lb (1.2 kg) R-134a

2.64 lb (1.2 kg) R-134a

2.64 lb (1.2 kg) R-404A

2.64 lb (1.2 kg) R-404A


2.64 lb (1.2 kg) R-134a

2.64 lb (1.2 kg) R-134a

2.64 lb (1.2 kg) R-404A

2.64 lb (1.2 kg) R-404A


2.86 lb (1.3 kg) R-134a

2.86 lb (1.3 kg) R-134a

3.52 lb (1.6 kg) R-452A

3.52 lb (1.6 kg) R-452A


3.52 lb (1.6 kg) R-134a

3.52 lb (1.6 kg) R-134a

3.75 lb (1.7 kg) R-452A

3.75 lb (1.7 kg) R-452A


4.20 lb (1.9 kg) R-452A

4.20 lb (1.9 kg) R-452A

Defrost Method (10/ MAX 10/ MAX 30 versions)   Hot Gas
Defrost thermostat (Klixon) (10/ MAX 30 versions):

Opens

Closes

48.0 ± 37.4 F (8.9 ± 3.0 C)

36.0 ± 37.4 F (2.2 ± 3.0 C)

Liquid injection switch (R-404A/ R452A):

Opens

Closes

48.0 ± 37.4 F (93 ± 3.0 C)

36.0 ± 37.4 F (110 ± 3.0 C)

High Pressure Cutout Switch (HPCO), R-134a

Opens

Closes

300 ± 10 psi (2,068 ± 70 kPa)

200 ± 10 psi (1,379 ± 70 kPa)

High Pressure Cutout Switch (HPCO), R-404A

Opens

Closes

450 ±10 psi (3,100 ± 70 kPa)

375 ±10 psi (2,585 ± 70 kPa)

CSPS (Condenser Pressure Control Switch)

Opens

Closes

300+20 psi/-0 psi (2,068+138 kPa/-0 kPa)

200 ± 20 psi (1,379 ± 138 kPa)

Low Pressure Cutout Switch (LPCO)

Opens

Closes

5 to 11 inch vacuum

4 to 7 psi (27.6 to 48.3 kPa)

Suction Pressure Regulator (SPR) Valve Setting - Model MAX 10 & 30 Versions  

29 psi (199.95 kPa)