i Preface For None
|
Note
|
|
Note
|
This manual is published for informational purposes only and the information furnished herein should not be considered as all-inclusive or meant to cover all contingencies. If more information is required, consult your Thermo King Service Directory for the location and telephone number of the local dealer.
Thermo King’s warranty shall not apply to any equipment which
has been so installed, maintained, repaired or altered as, in the
manufacturer’s judgment, to affect its integrity.
Manufacturer shall have no liability to any person or entity for any personal injury, property damage or any other direct, indirect, special, or consequential damages whatsoever, arising out of the use of this manual or any information, recommendations or descriptions contained herein. The procedures described herein should only be undertaken by suitably qualified personnel. Failure to implement these procedures correctly may cause damage to the Thermo King unit or other property or personal injury.
There is nothing complicated about operating and maintaining your Thermo King unit, but a few minutes studying this manual will be time well spent.
Performing pre-trip checks and enroute inspections on a regular basis will minimize operating problems. A regular maintenance program will also help to keep your unit in top operating condition. If factory recommended procedures are followed, you will find that you have purchased the most efficient and dependable temperature control system available.
All service requirements, major and minor, should be handled by a Thermo King dealer for four very important reasons:
They are equipped with the factory recommended tools to perform all service functions.
They have factory trained and certified technicians.
They have genuine Thermo King replacement parts.
The warranty on your new unit is valid only when the repair and replacement of component parts is performed by an authorized Thermo King dealer.
EMEA: The product includes software that is licensed under a non‐exclusive, non-sublicensable, terminable and limited license to use the software as installed on the product for its intended purpose. Any removal, reproduction, reverse engineering, or other unauthorized use of the software is strictly prohibited. Hacking the product or installing unapproved software may void the warranty. The owner or operator shall not reverse engineer, decompile, or disassemble the software, except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation. The product may include third party software separately licensed as specified in any documentation accompanying the product or in an about screen on a mobile application or website that interfaces with the product. You are obliged to complete the declaration for “THERMO KING EQUIPMENT SOFTWARE LICENSE AGREEMENT” before you put your unit in operation.
This is located in your language at the following location: https://www.emea-user-manuals.thermoking.com “THERMO KING EQUIPMENT SOFTWARE LICENSE AGREEMENT”.
Thermo Assistance is a multi-lingual communication tool designed to put you in direct contact with an authorized Thermo King dealer.
Thermo Assistance should only be contacted for breakdown and repair assistance.
To use this system, you need the following information before you call: (phone charges will apply)
Contact Phone Number
Unit Type
Thermostat Temperature Setting
Ambient temperature
Probable Cause of Fault
Warranty Details of the Unit
Payment Details for the Repair
Leave your name and contact number and a Thermo Assistance Operator will call you back. At this point you can give details of the service required and the repair will be organized.
No payment at point of repair for customers with a ThermoKare service contract or with a guaranty of payment from their Thermo King or FRIGOBLOCK home-dealer
For general inquiries please contact your local Thermo King and/or FRIGOBLOCK dealer.
Go to www.europe.thermoking.com and select dealer locator for your local Thermo King/FRIGOBLOCK dealer.
Or refer to the Service Directory for contact information.
Or use a Application for mobile devices, download TK Tek-Marine or TK Controller.
Let your voice be heard!
Your feedback will help improve our manuals. The survey is accessible through any internet-connected device with a web browser.
Scan the Quick Response (QR) code or click Technical Publications EMEA Feedback to complete the survey.
Thermo King®/ FRIGOBLOCK recommends that all service be performed by a Thermo King/FRIGOBLOCK dealer and to be aware of several general safety practices.
Safety advisories appear throughout this manual as required. Your personal safety and the proper operation of this unit depend upon the strict observance of these precautions. The four types of advisories are defined as follows:
Although fluorocarbon refrigerants are classified as safe, use caution when working with refrigerants or in areas where they are being used.
Observe the following precautions when working with or around refrigerant oil:
REFRIGERANT
Eyes: For contact with liquid, immediately flush eyes with large amounts of water and get prompt medical attention.
Skin: Flush area with large amounts of warm water. Do not apply heat. Remove contaminated clothing and shoes. Wrap burns with dry, sterile, bulky dressing to protect from infection. Get prompt medical attention. Wash contaminated clothing before reuse.
Inhalation: Move victim to fresh air and use Cardiopulmonary Resuscitation (CPR) or mouth-to-mouth resuscitation to restore breathing, if necessary. Stay with victim until emergency personnel arrive.
Frost Bite: In the event of frost bite, the objectives of First Aid are to protect the frozen area from further injury, warm the affected area rapidly, and to maintain respiration.
REFRIGERANT OIL
Eyes: Immediately flush with large amounts of water for at least 15 minutes. Get prompt medical attention.
Skin: Remove contaminated clothing. Wash thoroughly with soap and water. Get medical attention if irritation persists.
Inhalation: Move victim to fresh air and use Cardiopulmonary Resuscitation (CPR) or mouth-to-mouth resuscitation to restore breathing, if necessary. Stay with victim until emergency personnel arrive.
Ingestion: Do not induce vomiting. Immediately contact local poison control center or physician.
ENGINE COOLANT
Eyes: Immediately flush with large amounts of water for at least 15 minutes. Get prompt medical attention.
Skin: Remove contaminated clothing. Wash thoroughly with soap and water. Get medical attention if irritation persists.
Ingestion: Do not induce vomiting. Immediately contact local poison control center or physician.
BATTERY ACID
Eyes: Immediately flush with large amounts of water for at least 15 minutes. Get prompt medical attention. Wash skin with soap and water.
Skin: Immediately remove contaminated clothing. Wash skin with large volumes of water, for at least 15 minutes. Wash skin with soap and water. Do not apply fatty compounds. Seek immediate medical assistance.
Inhalation: Provide fresh air. Rinse mouth and nose with water. Seek immediate medical assistance.
Ingestion: If the injured person is fully conscious: make the person drink extensive amounts of milk. Do not induce vomiting. Take the injured person immediately to a hospital.
ELECTRICAL SHOCK
Take IMMEDIATE action after a person has received an electrical shock. Get quick medical assistance, if possible.
The source of the shock must be quickly stopped, by either shutting off the power or removing the victim. If the power cannot be shut off, the wire should be cut with a non-conductive tool, such as a wood-handle axe or thickly insulated cable cutters. Rescuers should wear insulated gloves and safety glasses and avoid looking at wires being cut. The ensuing flash can cause burns and blindness.
If the victim must be removed from a live circuit, pull the victim away with a non-conductive material. Use wood, rope, a belt or coat to pull or push the victim away from the current. DO NOT TOUCH the victim. You will receive a shock from current flowing through the victim’s body. After separating the victim from power source, immediately check for signs of a pulse and respiration. If no pulse is present, start Cardiopulmonary Resuscitation (CPR). If a pulse is present, respiration might be restored by using mouth-to-mouth resuscitation. Call for emergency medical assistance.
ASPHYXIATION
Move victim to fresh air and use Cardiopulmonary Resuscitation (CPR) or mouth-to-mouth resuscitation to restore breathing, if necessary. Stay with victim until emergency personnel arrive.
The Service decal is located in an appropriate location internally. This decal gives you the information to access/download your unit operator manual, but also the safety icons associated with your unit. These safety icons are directly associated with the information within this chapter. You can see the explanations for these icons starting from the beginning of this chapter.
Thermo King Vehicle Powered Truck Units are two-piece units comprised of a condenser and evaporator designed for fresh, frozen, and deep-frozen applications on small trucks and vans.
A belt driven compressor powered by the vehicle battery. It provides constant cooling and heating capacity independent of the vehicle engine. Where electric stand-by is required, an AC motor is fitted in the condenser. The aerodynamic condenser can be roof or front mounted, depending on the vehicle body shape.
The user-friendly Direct Smart Reefer (DSR) controller makes operating your unit simple, while its modular design allows for ease of service.
B-Series Units Include:
B-100. B-100 ECO: for fresh temperature applications above 0°C.
B-100 MAX: for frozen temperature applications below 0°C and down to -32°C.
There are five basic models :
Model 10: Cool and Defrost with only vehicle powered engine driven compressor operation.
Model 20: Cool and Defrost with both battery or electric standby compressor operation
Model 30: Electric heat, Cool, and Defrost with only vehicle powered engine driven compressor operation.
Model 50: Electric heat, Cool, and Defrost with both battery or electric standby compressor operation.
Two add-on heat options are available:
Coolant Heat (Models 10 and 20 only).
Coolant and Electric Heat (Model 20 only).
Condenser - Lightweight design, easy to service with automotive grade polypropylene cover.
Evaporator - Ultra slim design, aluminum construction automotive grade Acrylonitrile Butadiene Styrene (ABS) cover.
Compressor(s) - Industry-standard reciprocating compressor that delivers excellent performance in a compact size. For increased reliability and performance.
Controls - User friendly Direct Smart Reefer (DSR) In-Cab controller.
Refrigerant - R-134a, R-452A or R-404A (depending on unit model).
Electric Standby
Hot Gas, Electric or Coolant Heating
Door Switch Kit
Discharge Muffler Kit
Snow Covers
Refrigeration Hose / Harness Covers
Roof Top Mounting Kit
TracKing®
Electric Standby Plug (230V single phase 50Hz/60Hz or 115V single phase 60Hz options)
The system consists of the following main components:
All B-Series units are battery driven, and therefore there is no need for a compressor in the engine department. Electric standby models however, have an electric motor that operates a reciprocating compressor located inside the condenser.
The condenser is located on the roof of the vehicle or on the front of the cargo box. The cover can easily be removed to access the fuses or service the unit.
The Electronic Control System has the following characteristics:
Auto Start
Soft Start
Active Display
Lit Keypad
Total Hourmeter
Electric Standby Compressor Hourmeter
Low Battery Voltage Alarm
Buzzer
Unit Control without HMI
Manual or Automatic Defrost
Maintenance Warning
Return Air Temperature Sensor
Setpoint Temperature Reading
Electric Power Warning
Auto Start: Should the unit stop due to a failure in the power supply, whether during on-the-road or electric standby operation, it will start up again as soon as the power supply is re-established.
Soft Start: All operation modes remain inactive for a few seconds after an Auto Start.
Active Display: The HMI display is always active and backlit except when the unit is disconnected (no power) or when the unit is connected but has been manually switched off from the HMI (when there is no active alarm).
Lit Keypad: The HMI keys are always lit except when the unit is disconnected (no power) or when the unit is connected but has been manually switched off from the HMI (when there is no active alarm). The On/Off key is always lit except when the unit is disconnected (no power), and thus indicates the presence of power in the unit.
Total Hourmeter: Total number of hours the unit is in operation.
Electric Standby Compressor Hourmeter: Compressor hours in electrical standby mode.
Low Battery Voltage Alarm: Disconnects the unit when the battery voltage falls below 10.5V in 12VDC systems or below 21V in 24VDC systems.
Buzzer: It is energised when the vehicle battery and the electric power supply are connected at the same time. It is also energised if the doors are opened while the refrigeration unit is running.
Unit Control without HMI: The unit can also be operated by the Electronic Control System without the HMI, under conditions selected by the HMI before it is disconnected.
Manual or Automatic Defrost: It is possible to choose between manual or automatic defrost.
Maintenance Warning: On-screen warning of the need to carry out maintenance on the unit.
Return Air Temperature Sensor: On-screen reading of the temperature in the load compartment. In bi-temperature units, the temperature in both compartments can be read on the same screen.
Setpoint Temperature Reading: On-Screen Setpoint Temperature Reading. In bi-temperature units, the setpoint temperature of both compartments can be read on the same screen.
Electric Power Warning: On-screen warning that the unit is connected to an electric power supply.
| 1. Display | It is always active and backlit except when the unit is disconnected (no power) or when the unit is connected but has been manually switched off from the HMI. It normally displays the return air temperature (of both load compartments in multi-temperature units). |
| 2. On/Off Key | This key is used to start/stop the unit. It is always lit except when the unit is disconnected (no power) and thus acts as an indicator of the presence of power in the unit. |
| 3. Select Key | Selects prompt screens and information screens. |
| 4. Up Key | Is used to increase the setpoint temperature. |
| 5. Down Key | Is used to reduce the setpoint temperature. |
| 6. Enter Key | Is used to enter a new command such as manual defrost, etc. |
| 7. Buzzer | It is energised when the vehicle battery and the electric power supply are connected simultaneously. It is also energized if the doors are opened while the refrigeration unit is running. |
| 8. Cool Symbol | (Thermometer with an arrow pointing downward). The unit is cooling. |
| 9. Heat Symbol | (Thermometer with an arrow pointing upward). The unit is heating. |
| 10. °C/°F Symbol | Indicates whether the on-screen temperature reading is in degrees Celsius (C) or degrees Fahrenheit (F). |
| 11. Alarm Symbol | Indicates that there is an alarm in the system. |
| 12. Maintenance Symbol | Warns of the need to carry out maintenance to the unit. |
| 13. Defrost Symbol | Indicates the unit is in Defrost Mode. |
| 14. Electrical Symbol | Indicates that the unit is in Electric Standby. |
| 15. Condenser Defrost Symbol | Indicates the condenser unit is in defrost mode (turns on at the same time as defrost symbol 13). |
| 16. Combined Compartment Symbol | Indicates that the multi-temperature unit is working as a single temperature unit. |
The unit’s controls and refrigeration components operate on 12 Vdc or 24 Vdc (must match the voltage of the vehicle alternator)
Electric Standby units have a standby motor that operates on 230 Vac, 400 Vac 3 ph when connected to a remote power source. A transformer in the condenser unit converts the (NOT 115 V) 230 Vac 1 ph or 400 Vac 1 ph to 12 or 24 Vdc to operate the unit’s controls and refrigeration components.
The electrical components are protected by various fuses.
Main Power
Fuse - The main power fuse is located in the vehicle’s engine
compartment and is connected directly to the vehicle’s battery.
This in-line fuse is non-serviceable and must only be replaced
by an authorized Thermo King Dealer.
Ignition Power Fuse - The ignition power fuse is connected to the vehicle’s fused ignition system. Depending on the vehicle, the location of the fuse panel could be located inside the cab or under the hood of the vehicle.
Unit Component Fuses - These fuses are located in the condenser unit. Remove the condenser cover to access them. Depending on your model, some fuses may not be present Refer to ().
Units qualified for pharmaceutical applications under Thermo King protocol are configured with specific Pharma configuration file and parameters loaded during commissioning by your local dealer. Evaporators fans have to run during the Null Cycle.
Thermo King recommends to run the unit with the recommended Setpoints below:
Efficient loading practices and operating procedures have to be followed to ensure optimum air circulation and temperature management.
In truck-driven units, temperature control is based on two values: The setting (Setpoint) of the electronic thermostat and the evaporator return temperature. The difference between these two temperatures will determine the mode of operation: cool, heat, or null.
Cool: When the temperature in the load compartment is higher than the setpoint, the unit runs in cool mode to reduce the evaporator return temperature.
Heat: When the temperature in the load compartment is lower than the setpoint, the unit changes to heat mode to raise the evaporator return temperature.
Null: Once the Setpoint Temperature has been reached, and while the temperature remains between XºC/F above or below the setpoint, there is no demand for transfer of heat or cold, and the unit runs in null mode.
Defrost: After a scheduled period of time in cool mode, between 1 and 8 hours, the unit runs in this fourth mode of operation to eliminate ice that has accumulated in the evaporator or condenser coil. Defrost can be initiated automatically or manually.
Factory setting for X is 3ºC (5ºF). During unit installation, this value can be adjusted by between 1 and 5ºC (2 and 9ºF) in increments of 1ºC/F.
Units with R-134a refrigerant: Units Recommended for Fresh Cargo applications. Temperatures can be controlled from -20ºC to +22ºC (-4ºF to +71ºF).
Units with R-404A /R-452A refrigerant: Temperatures can be controlled from -20ºC to +22ºC (-4ºF to +71ºF).
Year of manufacture: Reference Serial Plate.
Installation and commissioning are to be carried out by an authorised Thermo King Dealer in accordance with Thermo King procedures and drawings. Exceptions to this with the written authorisation of the manufacturer only.
Start the vehicle.
Press the On/Off Key located in the HMI. The HMI display will be activated.
Check the setpoint and adjust if necessary.
Connect the external power supply to the electric power receptacle. Verify the power supply is of the correct voltage and phase for the unit.
Press the On/Off Key located in the HMI. The HMI display will be activated. The electric symbol will appear on the screen.
Check the setpoint and adjust if necessary.
Regular monitoring of the unit is recommended, the frequency of this monitoring will depend on the type of cargo.
The operating mode, whether engine-driven or electric standby, is selected automatically. When the unit is connected to an electric power source, engine-driven operation is automatically blocked. If the truck engine is started up while the power cable is still connected to the electrical power source, the unit will continue to operate in electric standby mode and the buzzer will be activated.
This is the display that appears when the On/Off key is pressed and the unit started. It normally displays the return air temperature (of both load compartments in bi-temperature units) and the current operating mode with the appropriate symbol.
Should there be an alarm, the alarm symbol will also appear on screen.
The Setpoint Temperature can be quickly and easily changed.
Press and release the Select key twice, and the current Setpoint Temperature and the letters SP will appear on screen.
Press the Up or Down arrow keys to select the desired Setpoint Temperature. Each time either of these buttons is pressed and released, the Setpoint Temperature will change one degree.
Press and release the Enter key to set the setpoint or press and release the Select key to set the setpoint and return to the Standard Display.
Press and release the Select key once, and the letters dEF will appear (flashing) on screen along with the present defrost condition OFF.
To activate manual defrost, press the Enter key and then the Up or Down key and the defrost condition will change to On.
Press the Select key twice to return to the Standard Display (three times in bi-temperature units and in reverse cycle units), where the letters dEF and the DEFROST symbol will appear when the defrost cycle starts (the load compartment temperature must be lower than 0ºC).
When the unit is not operating properly, the microprocessor records the alarm code, alerts the operator by displaying the Alarm symbol and, depending on the type of alarm, shuts the unit down.
There are three alarm categories:
The alarm stops the unit, and only the Alarm symbol appears on screen.
Once the alarm condition has been rectified, the On/Off key must be pressed to start up again.
Press and release the Select key to display the current alarm code on screen. If there is more than one active alarm, all the alarm codes on the unit can be viewed in sequence by pressing and releasing the Select key.
The alarm stops the unit, the Alarm symbol appears on screen and the unit starts up automatically once the alarm condition has been rectified.
Should a P1E alarm occur (return air temperature read error alarm code) appear, --- will appear on screen together with the alarm symbol, instead of the return air temperature reading.
Press and release the Select key to display the current alarm code on screen. If there is more than one active alarm, all the alarm codes on the unit can be viewed in sequence by pressing and releasing the Select key.
The buzzers are energized when the vehicle battery and the electrical supply are connected simultaneously (the unit continues running in Standby mode). The buzzers are also energized if the doors open, if this option is selected.
| OK TO RUN | CHECK AS SPECIFIED | TAKE IMMEDIATE ACTION |
| Alarm | Description | |
|---|---|---|
| Manual Start | ||
| OL |
Electric Motor Overload (Electric standby models only) - The electric motor overload relay has tripped due to excessive current draw. If the problem persists when the unit is restarted, contact your Thermo King Dealer. |
|
| bAt | Low Battery Voltage - Check vehicle battery. | |
| Auto Start | ||
| HP |
High Pressure Alarm - The system has detected excessively high discharge pressure. If the problem persists when the unit is restarted, contact your Thermo King Dealer. |
|
| LP |
Low pressure alarm – The system has detected excessively low suction pressure and has protected the compressor from an abnormal condition. Unit operation will resume automatically once the normal suction pressure is restored, and the alarm can be cleared (see Clearing Alarm Codes). Among other reasons, this could be due to:
If the problem persists when the unit is restarted, contact your Thermo King dealer. |
|
| PSE |
High Pressure Sensor Failure - The high pressure sensor has become faulty or disconnected. Contact your Thermo King Dealer. |
|
| tEP, tP4 | Thermal Protection Alarm - If the problem persists when the unit is restarted, contect your Thermo King Dealer | |
| dr1, dr2 |
Cargo Doors Are Open (Units with door switch option only) - Check if the Doors are open. if not, then the door switches are faulty, or improper door switch configuration. Contact your Thermo King Dealer. |
|
| tCO |
Control Module Overheating If the problem persists when the unit is restarted, contact your Thermo King Dealer. |
|
| SOF |
Software Failure Contact your Thermo King Dealer. |
|
| P1E |
Faulty Cargo Box Return Air Temperature Sensor - Faulty or disconnected return air temperature sensor. Contact your Thermo King Dealer. |
|
| C |
Communications Failure Contact your Thermo King Dealer. |
|
The alarm condition in the unit must first be corrected. See important note below. After resolving the alarm condition, press and release the Select key to remove existing Alarm codes. The Standard Display will appear once the Alarm codes have been cleared.
To Clear Alarm Codes:
Correct the cause of the alarm code.
Press the Select key to remove the alarm code.
If more than one alarm code is present, press the Select key to clear each alarm code individually.
Press the Select key once to show the Alarm screen. You will now see the bAt Alarm code.
Press the Select key again to acknowledge the alarm and Press the select key again and again until the screen returns to the standard Display.
From the Standard Display use the Select key to display:
Alarms (if any active).
Evaporator Manual Defrost.
Temperature Setpoint.
From the Standard Display press the Select key for three seconds to open the Hourmeter Menu, then use the Select key to display:
HC: Hours remaining to maintenance notice.
tH: The total amount of time the unit has been switched on protecting the load.
EC: Electric standby compressor operating hours.
Return to Main Menu.
This chapter describes pre-loading inspections, loading procedures, post-loading procedures, post-loading inspections, and enroute inspections. Thermo King refrigeration units are designed to maintain the required product load temperature during transit. Follow these recommended loading and enroute procedures to help minimize temperature related problems.
Thermostat: Adjust the thermostat setting to above and below the compartment temperature to check thermostat operation (see Operating Modes).
Pre-cooling: With the thermostat set at the desired temperature, run the unit for half-an-hour to one hour (or longer if possible) before loading the truck. Pre-cooling eliminates residual heat and acts as a good test of the refrigeration system.
Defrost: When the unit has finished pre-cooling the truck interior - the evaporator temperature should have dropped below 2ºC (35.6ºF) - initiate a defrost cycle with the manual defrost switch. The defrost cycle should stop automatically.
To minimise frost accumulation in the evaporator coil and a heat increase inside the load compartment, ensure that the unit is OFF before opening the doors (The unit may continue to run when the truck is being loaded in a warehouse with the doors closed).
Carefully check and record the load temperature when loading the truck. Note whether any products are out of temperature range.
Load the product in such a way that there is sufficient space for the air to circulate throughout the load. DO NOT block the evaporator inlet or outlet.
Product should be pre-cooled before loading. Thermo King units are designed to maintain the load at the temperature at which it is loaded. Transport refrigeration units are not designed to reduce the load temperature.
Verify all doors are closed and locked.
Adjust the thermostat to the desired temperature setpoint.
Start the unit.
Half an hour after loading the truck, defrost the unit for a moment by pressing the Manual Defrost switch. If the coil temperature drops to below 2ºC (35.6ºF), the unit will defrost. The defrost cycle should stop automatically.
Contact your Thermo King dealer for refrigeration system service or maintenance.
| Displacement (cc) | 47.7 |
| Number of cylinders | 6 |
Please also refer to TK 61654-18-WA Thermo King EMEA Unit Limited Warranty for Vehicle Powered Truck Units.
Inspection and Service intervals are determined by the number of unit operating hours and by the age of the unit. Examples are shown in the table below. Your Dealer will prepare a schedule to suit your specific needs.
Service Record: Each inspection and service performed should be recorded on your Dealer Service Record.
| Interim Inspection | Complete PM | Full Service |
|---|---|---|
|
A Service Every 500 hours or every 6 months (whichever comes first) |
B Service Every 1500 hours or every 12 months (whichever comes first) |
C Service Every 3000 hours or every 24 months (whichever comes first) |
| Pretrip | Inspect/Service These Items | |
|---|---|---|
| • | Listen for unusual noises, vibrations, etc. | |
| • | Visually inspect unit for fluid leaks. (fuel, coolant, oil and refrigerant). | |
| • | Visually inspect unit for damaged, loose or broken parts (includes air ducts and bulkheads if so equipped). | |
| • | Visually inspect belt. | |
|
Note For further
best practices, please go to www.europe.thermoking.com/best-practices.
|
||
The unit must be presented at the buyers expense at an authorised Thermo King dealer or service provider for an inspection. The inspection will verify that the unit has been correctly maintained and any upgrades or repairs deemed necessary will be carried out. Subject to a satisfactory inspection, the second twelve months warranty cover will be authorised. This is illustrated in the table above.
The following Weekly Pretrip Inspection should be completed before starting the unit and loading the truck. While the weekly inspection in not a substitute for regularly scheduled maintenance inspections, it is important part of the preventive maintenance program designed to head off operating problems before they happen.
Leaks: Inspect for refrigerant leaks and worn refrigerant lines.
Battery: Terminals should be properly tightened and show no signs of corrosion.
Belts: Inspect for cracks, wear, and proper belt tension.
Mounting Bolts: Verify bolts are properly tightened.
Electrical: Electrical connections should be securely fastened. Wires and terminals should be free of corrosion, cracks, or moisture.
Structural: Visually check for physical damage.
Coils: The condenser and evaporator coils should be clean and free of debris.
Washing with clean water should be sufficient. The use of cleaning agents or detergents is strongly discouraged due to the possibility of degradation of the construction. If using a power washer, the nozzle pressure should not exceed 600 psi (41 bar). For the best results, spray the coil perpendicular to the face of the coil. The spray nozzle should be kept between 1 inch and 3 inches (25 to 75 millimeters) from the coil surface. If necessary to use a chemical cleaner or detergent use a cleaner that does not contain any hydrofluoric acids and is between 7 and 8 on the pH scale. Ensure dilution instructions provided by the detergent supplier are followed. In case of doubt about the compatibility of the detergent with the type of materials listed above, always ask the supplier a written confirmation of the compatibility. Should a chemical cleaner be required, it is MANDATORY that all components are thoroughly rinsed with water even if the instructions of the cleaner specify that it is a “no rinse” cleaner. Failure to comply with above mentioned guidelines will lead to a shortened life of the equipment to an indeterminable degree. The repeated transportation of meat and fish waste can cause extensive corrosion to the evaporator coils and evaporator section tubing over time due to ammonia formation and can reduce the lifespan of the coils. Appropriate additional measures should be taken to protect the coils against the aggressive corrosion that can result from transportation of such products.
Load Compartment: Inspect the interior and exterior of the truck for any damage. Any damage to the walls or insulation should be repaired.
Defrost Drains: Check the defrost drain hoses and fittings to ensure they are not blocked.
Doors: Verify doors and weather seals are in good condition and seal hermetically.
Sight glass: Check that the refrigerant charge sight glass on the running unit is totally full (the cargo compartment temperature must be approximately 0ºC).
Clean the outside cover of the unit. Use a damp cloth and neutral detergents. Do not use harsh cleaning products or solvents.
Check for leaks.
Check for loose or missing hardware.
Check for physical damage to the unit.
To ensure that your Thermo King unit operates reliably and economically over its full life, and to avoid limiting its warranty cover, the appropriate inspection and service schedule must be followed. Inspection and Service intervals are determined by the number of unit operating hours and by the age of the unit. Examples are shown in the table below. Your Dealer will prepare a schedule to suit your specific needs.
Each inspection and service performed should be recorded on the Service Record Sheet found at the back of this manual.
Refer to the previous page for checks that should be carried out
daily/weekly on the unit. Please work with your Dealer in order to
create a maintenance schedule which fits your needs.
Thermo King has extended the limited warranty on new units from
3,000 total hours to a maximum of 4,000 compressor run hours within
the 2 year warranty period.
This limited warranty is
dependent on the owner and/ or operator adhering to the preventative
maintenance schedule as advised by your Thermo King Dealer.
At Thermo King®, we recognize the need to preserve the environment and limit the potential harm to the ozone layer that can result from allowing refrigerant to escape into the atmosphere.
We strictly adhere to a policy that promotes the recovery and limits the loss of refrigerant into the atmosphere.
In addition, service personnel must be aware of local regulations concerning the use of refrigerants and the certification of technicians. For additional information on regulations and technician certification programs, contact your local THERMO KING dealer.
Last Updated : 10/04/2023